[Paper Review] Force Plate Monitoring of Human Hemodynamics
This study introduces a noninvasive method using force plate measurements to monitor human hemodynamics by detecting body micro-movements caused by cardiac activity and pulse wave propagation. By analyzing the first Cartan curvature of the six-dimensional force and moment signal curve, the method accurately identifies key cardiac events—such as valve closures and blood ejection—with millisecond precision, matching invasive catheterization data and enabling real-time, online monitoring of hemodynamic dynamics without radiation or ionizing agents.
We show that the recoils of the body caused by cardiac motion and blood circulation provide a noninvasive method capable to display the motions of the heart muscle and the propagation of the pulse wave along aorta and its branches. The results are compared with the data obtained invasively during a heart catheterization. We show that the described noninvasive method is able to determine the moment of a particular heart movement or the time when the pulse wave reaches certain morphological structure.
Motivation & Objective
- To develop a noninvasive method for monitoring internal hemodynamic processes using body micro-movements induced by cardiac activity.
- To identify and localize key cardiac events—such as valve closures and pulse wave propagation—through force plate measurements.
- To validate the method against invasive catheterization data, ensuring clinical relevance and accuracy.
- To demonstrate the robustness of geometric invariants in detecting hemodynamic events regardless of body position or patient orientation.
- To establish the feasibility of real-time, online monitoring of cardiac function using only a force plate and ECG.
Proposed method
- The study uses a Bertec force plate (model 4060A) to measure six components of force and moment (Fx, Fy, Fz, Mx, My, Mz) at 1 kHz sampling rate during relaxed supine and prone positions.
- A seven-dimensional time series is formed by combining the six force/moment components with the ECG signal, forming a 6D signal curve in space.
- The geometric invariants of the signal curve are analyzed using Cartan curvatures, particularly the first curvature κ₁(t), which is invariant under rotation, translation, and reparametrization.
- The Frenet-Serret formalism is applied to define the distinguished frame and curvatures along the signal curve, enabling detection of abrupt changes linked to hemodynamic events.
- The method relies on the principle that mechanical events (e.g., pulse wave scattering at arterial bifurcations) alter the signal curve’s geometry, making them detectable via curvature changes.
- The analysis focuses on the first Cartan curvature, which is robust to noise and effectively captures hemodynamic timing markers such as valve events and ventricular filling phases.
Experimental results
Research questions
- RQ1Can force plate measurements detect the timing of key cardiac events such as aortic valve closure and mitral valve opening with high temporal precision?
- RQ2To what extent do geometric invariants of the force signal curve remain stable across different body positions, indicating robustness to external perturbations?
- RQ3How does the first Cartan curvature compare to invasive catheterization data in identifying the arrival time of the pulse wave at anatomical landmarks like the aortic arch or celiac artery?
- RQ4Is the curvature pattern of the force signal reproducible across multiple heartbeats and over time in the same individual?
- RQ5Can the method detect subtle hemodynamic changes, such as those induced by atrial contraction or rapid ventricular filling, without requiring invasive procedures?
Key findings
- The first Cartan curvature κ₁(t) successfully identifies the timing of major cardiac events, including the first and second heart sounds, with consistent time delays relative to the R-wave of the ECG.
- The mean time delay between the R-wave and the curvature peak corresponding to blood injection into the aortic root was 80 ms, with a standard deviation of 8 ms across 25 volunteers.
- The curvature pattern is stable over time: repeated measurements of the same subject after three months showed no significant shift in peak timing, indicating high reproducibility.
- The method is insensitive to body position—curvature peak locations remained unchanged when subjects were measured on their back or belly, confirming the invariance of geometric features.
- The curvature peaks associated with rapid ventricular filling and atrial systole were clearly visible and correlated with the derivative of ventricular pressure, confirming their physiological origin.
- The method enables real-time, noninvasive monitoring of hemodynamic processes, including pulse wave propagation and mechanical events in the heart, with accuracy comparable to invasive catheterization.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.