Skip to main content
QUICK REVIEW

[Paper Review] Linear and nonlinear viscoelastic arterial wall models: application on animals

Arthur Ghigo, Xiaofei Wang|arXiv (Cornell University)|Jul 27, 2016
Cardiovascular Health and Disease PreventionMedicine22 references34 citations
TL;DR

This study proposes a nonlinear Kelvin-Voigt viscoelastic model for arterial walls, fitted to experimental pressure-radius data from a sheep’s arterial network. It demonstrates that the viscoelastic relaxation time remains nearly constant across the network, leading to increased damping of high-frequency pulse waves—especially in peripheral arteries—due to rising viscoelastic coefficients compensating for stiffer walls.

ABSTRACT

This work deals with the viscoelasticity of the arterial wall and its influence on the pulse waves. We describe the viscoelasticity by a non-linear Kelvin-Voigt model in which the coefficients are fitted using experimental time series of pressure and radius measured on a sheep's arterial network. We obtained a good agreement between the results of the nonlinear Kelvin-Voigt model and the experimental measurements. We found that the viscoelastic relaxation time-defined by the ratio between the viscoelastic coefficient and the Young's modulus-is nearly constant throughout the network. Therefore, as it is well known that smaller arteries are stiffer, the viscoelastic coefficient rises when approaching the peripheral sites to compensate the rise of the Young's modulus, resulting in a higher damping effect. We incorporated the fitted viscoelastic coefficients in a nonlinear 1D fluid model to compute the pulse waves in the network. The damping effect of viscoelasticity on the high frequency waves is clear especially at the peripheral sites.

Motivation & Objective

  • To develop a nonlinear viscoelastic model for arterial wall mechanics that accurately captures experimental pressure-radius dynamics.
  • To estimate viscoelastic coefficients (φ₀, φNL) from direct in-vivo measurements of pressure and radius in a sheep’s arterial network.
  • To investigate the influence of viscoelasticity on pulse wave propagation in a 1D hemodynamic model of the arterial network.
  • To determine whether the viscoelastic relaxation time (φ₀/E) remains approximately constant across different arterial sites.
  • To evaluate the impact of viscoelasticity on high-frequency wave damping, particularly in peripheral arteries.

Proposed method

  • A nonlinear Kelvin-Voigt model is used: (1−η²)(R/h)P = Eε + φ₀∂ε/∂t + φNL(∂ε/∂t)², where ε is the strain and η is a non-dimensional parameter.
  • The viscoelastic coefficients φ₀ and φNL are estimated via linear regression on experimental time series of pressure and radius from sheep arterial segments.
  • The model is validated by comparing simulated pressure-radius loops with measured data, achieving good agreement.
  • A 1D blood flow model is implemented using the fitted viscoelastic parameters to simulate pulse wave propagation in a realistic arterial network.
  • The network includes virtual terminal vessels to minimize reflections, with parameters derived from Murray’s law and matched boundary conditions.
  • Simulations compare elastic and viscoelastic wall models, focusing on waveform smoothing and high-frequency damping.

Experimental results

Research questions

  • RQ1How well does a nonlinear Kelvin-Voigt viscoelastic model fit experimental pressure-radius data from sheep arterial segments?
  • RQ2Is the viscoelastic relaxation time (φ₀/E) approximately constant across different arterial sites in the network?
  • RQ3What is the impact of viscoelasticity on the damping of high-frequency components in pulse waveforms, especially in peripheral arteries?
  • RQ4How do the viscoelastic coefficients (φ₀ and φNL) vary with arterial stiffness (E) along the arterial tree?
  • RQ5Does the inclusion of the nonlinear term (∂ε/∂t)² significantly improve model accuracy compared to linear viscoelastic models?

Key findings

  • The nonlinear Kelvin-Voigt model with φNL term provides a good fit to experimental pressure-radius data across all arterial sites studied.
  • The viscoelastic relaxation time (φ₀/E) is nearly constant across the arterial network, with values ranging from -0.915 to -1.380 across seven arteries.
  • The viscoelastic coefficient φ₀ increases in peripheral arteries (e.g., femoral and carotid arteries) to compensate for higher Young’s modulus (E), resulting in stronger damping.
  • The viscoelastic model significantly dampens high-frequency components in the pulse waveforms, especially in peripheral arteries like the carotid and femoral arteries.
  • The simulated flow waveforms with the viscoelastic model are smoother than those from the elastic model, particularly at the Carotid Artery and Medial Descending Aorta.
  • The nonlinear term (∂ε/∂t)² was found to be essential for fitting experimental data, while the φNL(∂ε/∂t)² term was negligible and thus excluded from the final model.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.