Skip to main content
QUICK REVIEW

[Paper Review] Hibou: A Family of Foundational Vision Transformers for Pathology

Dmitry Nechaev, Alexey Pchelnikov|arXiv (Cornell University)|Jun 7, 2024
Digital Imaging for Blood DiseasesComputer Science15 citations
TL;DR

Hibou pretrains two vision transformer models (Hibou-B and Hibou-L) with DINOv2 on a large histopathology dataset, achieving state-of-the-art patch- and slide-level performance, with Hibou-L leading on average across datasets and Hibou-B released openly.

ABSTRACT

Pathology, the microscopic examination of diseased tissue, is critical for diagnosing various medical conditions, particularly cancers. Traditional methods are labor-intensive and prone to human error. Digital pathology, which converts glass slides into high-resolution digital images for analysis by computer algorithms, revolutionizes the field by enhancing diagnostic accuracy, consistency, and efficiency through automated image analysis and large-scale data processing. Foundational transformer pretraining is crucial for developing robust, generalizable models as it enables learning from vast amounts of unannotated data. This paper introduces the Hibou family of foundational vision transformers for pathology, leveraging the DINOv2 framework to pretrain two model variants, Hibou-B and Hibou-L, on a proprietary dataset of over 1 million whole slide images (WSIs) representing diverse tissue types and staining techniques. Our pretrained models demonstrate superior performance on both patch-level and slide-level benchmarks, surpassing existing state-of-the-art methods. Notably, Hibou-L achieves the highest average accuracy across multiple benchmark datasets. To support further research and application in the field, we have open-sourced the Hibou models, which can be accessed at https://github.com/HistAI/hibou.

Motivation & Objective

  • Motivate improved generalization in digital pathology using foundation models and self-supervised pretraining.
  • Develop and compare two Hibou model variants (Hibou-B and Hibou-L) based on ViT architectures.
  • Show robustness and transferability of Hibou across patch- and slide-level tasks on diverse histopathology datasets.
  • Demonstrate open-sourcing of Hibou-B to accelerate reproducibility and community-driven development.

Proposed method

  • Pretrain Hibou-B (ViT-B/14) and Hibou-L (ViT-L/14) with DINOv2 on a proprietary dataset of 936,441 H&E and 202,464 non-H&E slides from 306,400 cases.
  • Create nonoverlapping patches from WSIs, filter backgrounds with Otsu thresholding, and randomly sample tissue patches for training.
  • Apply data augmentations (random rotation, flips, RandStainNA, color jitter) with RandStainNA enhancing stain-robustness for histology tasks.
  • Initialize weights randomly and train Hibou-B on 8 A100 GPUs (batch size 1024, 500k iterations) and Hibou-L on 32 A100 GPUs (batch size 1024, 1.175M iterations).
  • Evaluate on patch-level linear probing across six public datasets and perform slide-level weakly supervised classification with a frozen feature extractor and trainable pooling module.
  • Compare against public baselines (Phikon, Kaiko-B8, Virchow, RudolfV, Prov-GigaPath) and report top-1 accuracy and AUC metrics across datasets.
Figure 1: A distribution of tissue types and stains in our dataset
Figure 1: A distribution of tissue types and stains in our dataset

Experimental results

Research questions

  • RQ1How do Hibou-B and Hibou-L perform on patch-level tissue type classification across diverse datasets?
  • RQ2Do Hibou models generalize well to unseen public histopathology datasets when pretrained on proprietary data?
  • RQ3Can Hibou-L outperform prior state-of-the-art methods on patch-level benchmarks and slide-level subtasks?
  • RQ4What is the impact of model size and pretraining data scale on performance in histopathology foundation models?
  • RQ5Is Hibou-B suitable for open research and practical applications given its architecture and license?

Key findings

  • Hibou-L achieves the highest average accuracy across six patch-level datasets, surpassing several state-of-the-art models.
  • On patch-level benchmarks, Hibou-L consistently outperforms competing methods with an average top-1 accuracy of 0.919 across reported datasets (and Hibou-B 0.904).
  • Hibou-B and Hibou-L achieve strong slide-level performance, with Hibou-L attaining the highest AUC across BRCA, NSCLC, and RCC datasets in TCGA-based tests (0.946, 0.969, 0.996 respectively).
  • Hibou-L delivers superior patch-level features while using fewer parameters in comparison to some baselines, illustrating efficient representation learning for WSIs.
  • Hibou-B is released publicly under Apache 2.0 to support reproducibility and community-driven research.
Figure 2: Dataset used for training
Figure 2: Dataset used for training

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.