Skip to main content
QUICK REVIEW

[Paper Review] W-Net: A CNN-based Architecture for White Blood Cells Image Classification

Changhun Jung, Mohammed Abuhamad|arXiv (Cornell University)|Oct 2, 2019
Digital Imaging for Blood DiseasesComputer Science31 references21 citations
TL;DR

This paper proposes W-Net, a lightweight CNN architecture with three convolutional and two fully connected layers for classifying white blood cells (WBCs) into five types: neutrophils, eosinophils, basophils, lymphocytes, and monocytes. Trained on a large-scale real-world dataset of 6,562 images, W-Net achieves a state-of-the-art average accuracy of 97%, demonstrating strong performance on imbalanced data and transferability to public datasets through fine-tuning.

ABSTRACT

Computer-aided methods for analyzing white blood cells (WBC) have become widely popular due to the complexity of the manual process. Recent works have shown highly accurate segmentation and detection of white blood cells from microscopic blood images. However, the classification of the observed cells is still a challenge and highly demanded as the distribution of the five types reflects on the condition of the immune system. This work proposes W-Net, a CNN-based method for WBC classification. We evaluate W-Net on a real-world large-scale dataset, obtained from The Catholic University of Korea, that includes 6,562 real images of the five WBC types. W-Net achieves an average accuracy of 97%.

Motivation & Objective

  • To address the challenge of accurate white blood cell (WBC) classification, which is critical for diagnosing immune disorders and leukemia.
  • To develop a deep learning model that efficiently classifies the five major WBC subtypes with high accuracy despite class imbalance.
  • To evaluate the model on a real-world, large-scale dataset of 6,562 WBC images collected from The Catholic University of Korea.
  • To demonstrate the model's transferability by fine-tuning on public datasets like LISC, improving performance through pre-training.
  • To provide a publicly released, efficient, and accurate WBC classification model to support future research in medical image analysis.

Proposed method

  • W-Net employs a three-convolutional-layer backbone to extract hierarchical features from WBC images, followed by two fully connected layers for classification.
  • The model uses a softmax classifier to output probabilities across the five WBC classes: neutrophils, eosinophils, basophils, lymphocytes, and monocytes.
  • The architecture is designed with a small number of layers to ensure computational efficiency and reduce overfitting, especially on limited data.
  • Data augmentation and image normalization techniques were applied to enhance generalization and model robustness.
  • Transfer learning was evaluated by first pre-training W-Net on the private 6,562-image dataset and then fine-tuning on the LISC public dataset of 254 images.
  • 10-fold cross-validation was used to evaluate model stability and generalization across different data splits.

Experimental results

Research questions

  • RQ1Can a lightweight CNN architecture achieve high accuracy in classifying the five major WBC subtypes on a real-world, large-scale dataset?
  • RQ2How does W-Net perform compared to established architectures like ResNet in WBC classification tasks?
  • RQ3To what extent can W-Net be fine-tuned on public datasets like LISC to improve performance with limited labeled data?
  • RQ4How effective is W-Net in handling class imbalance, given the highly skewed distribution of WBC types in the human body?
  • RQ5Can a pre-trained W-Net model serve as a strong initialization for other researchers to fine-tune on new datasets, enhancing transfer learning in WBC image analysis?

Key findings

  • W-Net achieved an average classification accuracy of 97% on the private dataset of 6,562 real WBC images, outperforming existing state-of-the-art methods.
  • The model demonstrated strong robustness and generalization, achieving 96% average accuracy when fine-tuned on the LISC public dataset after pre-training on the larger private dataset.
  • Neutrophils and lymphocytes were classified with 100% accuracy across all folds, indicating high model confidence for these dominant classes.
  • Basophils and monocytes showed slightly lower but still high performance (96% and 88% average accuracy, respectively), highlighting the model’s capability on rare classes.
  • The ablation study confirmed that pre-training on a large private dataset significantly improved fine-tuning performance on smaller public datasets, validating the transfer learning potential of W-Net.
  • The model’s architecture, with only 16.8 million trainable parameters, proves effective and efficient for clinical deployment, balancing accuracy and computational cost.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.