[Paper Review] Limits on the Benefits of Energy Storage for Renewable Integration
This paper formulates energy storage operation in a single-bus power system as an infinite-horizon stochastic program to minimize average conventional generation or loss of load probability. It derives optimal control policies—showing that greedy storage charging using renewable excess and discharging to offset deficits achieves near-optimal performance with modest storage, even under uncertain net load, under IID and Laplace-distributed prediction errors.
The high variability of renewable energy resources presents significant challenges to the operation of the electric power grid. Conventional generators can be used to mitigate this variability but are costly to operate and produce carbon emissions. Energy storage provides a more environmentally friendly alternative, but is costly to deploy in large amounts. This paper studies the limits on the benefits of energy storage to renewable energy: How effective is storage at mitigating the adverse effects of renewable energy variability? How much storage is needed? What are the optimal control policies for operating storage? To provide answers to these questions, we first formulate the power flow in a single-bus power system with storage as an infinite horizon stochastic program. We find the optimal policies for arbitrary net renewable generation process when the cost function is the average conventional generation (environmental cost) and when it is the average loss of load probability (reliability cost). We obtain more refined results by considering the multi-timescale operation of the power system. We view the power flow in each timescale as the superposition of a predicted (deterministic) component and an prediction error (residual) component and formulate the residual power flow problem as an infinite horizon dynamic program. Assuming that the net generation prediction error is an IID process, we quantify the asymptotic benefits of storage. With the additional assumption of Laplace distributed prediction error, we obtain closed form expressions for the stationary distribution of storage and conventional generation. Finally, we propose a two-threshold policy that trades off conventional generation saving with loss of load probability. We illustrate our results and corroborate the IID and Laplace assumptions numerically using datasets from CAISO and NREL.
Motivation & Objective
- To determine the limits of energy storage in mitigating renewable energy variability and reducing reliance on conventional generation.
- To identify the optimal control policies for energy storage that minimize average conventional generation or loss of load probability.
- To quantify the amount of storage required to achieve significant benefits under realistic uncertainty models.
- To evaluate the performance of storage in multi-timescale power system operation using real-world data from CAISO and NREL.
Proposed method
- Formulates the power flow in a single-bus system with storage as an infinite-horizon average-cost stochastic program.
- Models net renewable generation as a superposition of deterministic predictions and stochastic prediction errors.
- Assumes prediction errors are i.i.d. and, under the Laplace distribution, derives closed-form stationary distributions for storage and conventional generation.
- Proposes a two-threshold control policy that balances conventional generation savings against loss of load risk.
- Uses dynamic programming to solve the residual power flow problem in each timescale.
- Validates results numerically using real load and wind generation data from CAISO and NREL.
Experimental results
Research questions
- RQ1How effective is energy storage in reducing the need for conventional generation due to renewable variability?
- RQ2What is the optimal control policy for energy storage that minimizes average conventional generation or loss of load probability?
- RQ3How much storage is required to achieve most of the benefits of energy storage under uncertain renewable generation?
- RQ4What are the asymptotic performance limits of storage when prediction errors are i.i.d. and Laplace-distributed?
- RQ5How do multi-timescale dynamics affect the design and performance of storage control policies?
Key findings
- The optimal policy for minimizing average conventional generation is greedy: storage is charged only with excess renewable generation and never with conventional generation.
- Under i.i.d. prediction errors, the stationary distribution of storage and conventional generation can be derived in closed form when errors follow a Laplace distribution.
- A two-threshold control policy is proposed that optimally trades off conventional generation savings against loss of load probability.
- Numerical results using CAISO and NREL data validate the i.i.d. and Laplace assumptions and confirm that most benefits are achieved with modest storage capacity.
- The study shows that significant reductions in conventional generation and loss of load probability are attainable even with limited storage, especially when prediction errors are well-modeled.
- The optimal policy avoids charging storage from conventional generation, which is suboptimal due to imperfect round-trip efficiency and linear cost structure.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.