Skip to main content
QUICK REVIEW

[Paper Review] Optimal Placement of Distributed Energy Storage in Power Networks

Christos Thrampoulidis, Subhonmesh Bose|arXiv (Cornell University)|Mar 23, 2013
Microgrid Control and OptimizationEngineering13 references3 citations
TL;DR

This paper formulates the optimal placement, sizing, and control of distributed energy storage in power networks to minimize generation costs via load shifting. Using a linearized DC power flow model and convex nondecreasing generation costs, it proves that for any fixed storage budget, there always exists an optimal solution assigning zero storage to generator-only buses connected via single transmission lines—regardless of demand, generation capacity, or line limits.

ABSTRACT

We formulate the optimal placement, sizing and control of storage devices in a power network to minimize generation costs with the intent of load shifting. We assume deterministic demand, a linearized DC approximated power flow model and a fixed available storage budget. Our main result proves that when the generation costs are convex and nondecreasing, there always exists an optimal storage capacity allocation that places zero storage at generation-only buses that connect to the rest of the network via single links. This holds regardless of the demand profiles, generation capacities, line-flow limits and characteristics of the storage technologies. Through a counterexample, we illustrate that this result is not generally true for generation buses with multiple connections. For specific network topologies, we also characterize the dependence of the optimal generation cost on the available storage budget, generation capacities and flow constraints.

Motivation & Objective

  • To determine the optimal placement, sizing, and control of distributed energy storage in power networks to minimize generation costs through load shifting.
  • To analyze the structural properties of optimal storage allocation under a linearized DC power flow model with fixed storage budget and deterministic demand.
  • To establish conditions under which storage should not be placed at generator-only buses connected via single transmission lines.
  • To characterize the dependence of optimal generation cost on storage budget, generation capacity, and line flow constraints for specific network topologies.
  • To provide theoretical justification for empirical observations that optimal storage placement rarely includes generator-only buses with single-line connections.

Proposed method

  • Formulates an infinite-horizon optimization problem over a single period, assuming periodic demand profiles and finite storage capacity with ramp rate constraints.
  • Uses a linearized DC power flow approximation to model active power flows, assuming small voltage angle differences and fixed voltage magnitudes.
  • Models generator costs as convex and nondecreasing functions, and incorporates storage inefficiencies through charging/discharging losses.
  • Applies duality and flow conservation arguments to prove structural properties of optimal solutions, particularly focusing on buses with single-line connections.
  • Employs a contradiction-based proof technique to show that assigning storage to single-line generator buses is suboptimal when generation costs are convex and nondecreasing.
  • Constructs feasible solutions for multi-bus networks by aggregating demand and line capacities, and compares optimal costs across simplified and original network models.

Experimental results

Research questions

  • RQ1Under what conditions is it optimal to assign zero storage capacity to generator-only buses connected via a single transmission line?
  • RQ2How does the optimal generation cost depend on the available storage budget, line flow limits, and generation capacities in specific network topologies?
  • RQ3Can the optimal storage placement problem be reduced to a single-bus equivalent problem under certain network conditions?
  • RQ4Is the optimal storage allocation invariant to the distribution of line capacities among multiple load-connected lines from a single generator?
  • RQ5Does the convexity and monotonicity of generation costs guarantee that storage should not be placed at single-line generator buses?

Key findings

  • When generation costs are convex and nondecreasing, there always exists an optimal storage allocation that assigns zero storage to generator-only buses connected to the network via a single transmission line.
  • This result holds for arbitrary demand profiles, generation capacities, line-flow limits, and storage technology characteristics.
  • A counterexample demonstrates that the result does not generally hold for generator buses with multiple connections to the network.
  • For networks with a single generator and multiple load buses, the optimal cost is equivalent to that of a single-bus storage problem with aggregated demand and total line capacity.
  • The optimal cost is non-increasing in the storage budget and depends on the maximum average load over any time interval.
  • The proof technique establishes that any solution assigning storage to a single-line generator bus can be modified to reduce total generation cost, leading to a contradiction if such a solution were optimal.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.