[Paper Review] Low coherency of wind induced seismic noise: Implications for gravitational wave detection
This study quantifies the low coherency of wind-induced seismic noise across 0.06–20 Hz at a gravitational wave detector site in Western Australia, demonstrating that wind reduces coherence lengths from hundreds of meters to just 2–40 m in key frequency bands. Using dense seismic arrays near buildings, trees, and shrubs, the authors show this incoherence severely degrades the performance of array-based vibration isolation and Newtonian noise cancellation—particularly at 2 Hz, where Wiener filtering effectiveness drops by a factor of five—highlighting critical design challenges for next-generation detectors.
Seismic noise poses challenges for gravitational wave detection. Effective vibration isolation and methods to subtract unsheildable Newtonian Noise are examples. Seismic arrays offer one way to deal with these issues assuming seismic coherency. In this paper we find that wind induced seismic noise is incoherent and will dramatically reduce the projected low frequency sensitivity of future gravitational wave detectors. To quantify this, we measure the coherence length of wind induced seismic noise from 0.06--20~Hz in three distinct locations: close to a building, among tall trees and in shrubs. We show that wind induced seismic noise is ubiquitous and reduces the coherence lengths form several hundred meters to 2--40~m for 0.06--0.1~Hz, from $>$60~m to 3--16~m for 1.5--2.5~Hz and from $>$35~m to 1--16~m around 16.6 Hz frequency bands in the study area. This leads to significant loss of velocity and angular resolution of the array for primary microseism, 5 times worse Newtonian Noise cancellation by wiener filtering at 2~Hz, while it does not pose additional challenge for Newtonian Noise cancellation between 10--20~Hz.
Motivation & Objective
- To quantify the coherence length of wind-induced seismic noise across 0.06–20 Hz at a gravitational wave detector site.
- To assess how wind-induced incoherence impacts the performance of seismic arrays used for vibration isolation and Newtonian noise cancellation.
- To evaluate the influence of local surface features—buildings, trees, and shrubs—on wind-induced seismic noise coherency.
- To determine whether existing array-based mitigation techniques, such as Wiener filtering, remain effective under windy conditions.
Proposed method
- Deployment of a dense seismic array with 3 sub-arrays at distinct locations: near a building, among tall trees, and in shrubs.
- Measurement of seismic coherence length using cross-spectral density and coherency functions between colocated seismometers.
- Comparison of coherence lengths under windy vs. non-windy conditions across three frequency bands: 0.06–0.1 Hz, 1.5–2.5 Hz, and 16.55–16.66 Hz.
- Use of beamforming and spectral analysis from a pilot study to identify wind-correlated seismic noise and guide array configuration.
- Application of Wiener filtering to simulate Newtonian noise cancellation performance under varying coherence conditions.
- Analysis of wind speed correlation with ground motion to assess wind as a proxy for noise subtraction.
Experimental results
Research questions
- RQ1How does wind-induced seismic noise affect the coherence length of ground motion across key gravitational wave detection frequencies (0.06–20 Hz)?
- RQ2What is the impact of local surface features—buildings, trees, and shrubs—on the coherency of wind-induced seismic noise?
- RQ3To what extent does wind-induced incoherence degrade the performance of seismic arrays in canceling Newtonian noise via Wiener filtering?
- RQ4Does the incoherence of wind-induced noise pose a greater challenge at low frequencies (below 10 Hz) compared to higher frequencies (10–20 Hz)?
- RQ5Can wind speed measurements serve as a viable proxy for subtracting wind-induced seismic noise in array-based systems?
Key findings
- Wind reduces coherence lengths from several hundred meters to 2–40 m in the 0.06–0.1 Hz band, severely limiting array resolution.
- In the 1.5–2.5 Hz band, coherence lengths drop from >60 m to 3–16 m, reducing Wiener filtering effectiveness by a factor of five at 2 Hz.
- At 16.6 Hz, coherence lengths decrease from >35 m to 1–16 m, but the impact is mitigated by building attenuation and short wavelengths.
- The incoherence of wind-induced noise is most pronounced in vegetated areas (trees and shrubs), which reduce coherence more than buildings.
- Wind-induced noise does not significantly impair Newtonian noise cancellation between 10–20 Hz due to short wavelengths and effective building shielding.
- The study confirms that wind-induced seismic noise is a highly local phenomenon, with coherence lengths strongly dependent on proximity to surface objects and wind conditions.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.