Skip to main content
QUICK REVIEW

[Paper Review] Measurement of the Electron Magnetic Moment

X. Fan, T. G. Myers|arXiv (Cornell University)|Sep 27, 2022
Radioactive Decay and Measurement TechniquesPhysics and Astronomy4 citations
TL;DR

This paper reports a 2.2-fold improvement in the precision of the electron magnetic moment measurement, achieving 1.3 parts in 10^13, using a single electron in a Penning trap at 50 mK. The result, consistent with the 2008 measurement, tests the Standard Model to 1 part in 10^12 and provides a new α⁻¹ = 137.035999166(15) [0.11 ppb], reducing uncertainty by a factor of ten compared to current α measurements.

ABSTRACT

The electron magnetic moment,$-μ/μ_B = g/2 = 1.001 \, 159 \, 652 \, 180 \, 59 \, (13) \, [0.13\, m{ppt}]$, is determined 2.2 times more accurately than the value that stood for 14 years. The most precisely determined property of an elementary particle tests the most precise prediction of the Standard Model (SM) to $1$ part in $10^{12}$. The test would improve an order of magnitude if the uncertainty from discrepant measurements of the fine structure constant $α$ is eliminated since the SM prediction is a function of $α$. The new measurement and SM theory together predict $α^{-1}=137.035 \, 999 \, 166 \, (15) \, [0.11 \, m{ppb}]$ with an uncertainty ten times smaller than the current disagreement between measured $α$ values.

Motivation & Objective

  • To improve the precision of the electron magnetic moment measurement by a factor of 2.2 compared to the previous 14-year benchmark.
  • To test the most precise prediction of the Standard Model (SM) for the electron g-factor to 1 part in 10^12.
  • To reduce the uncertainty in the fine structure constant α by combining the new measurement with SM theory, thereby resolving the 5.5σ discrepancy between recent α measurements.
  • To enable a more sensitive search for physics beyond the Standard Model (BSM) by reducing the uncertainty in the g/2 measurement.
  • To demonstrate a stable, low-noise experimental setup using a single electron in a cryogenic Penning trap with a 4.2 K self-shielding solenoid.

Proposed method

  • A single electron is trapped in a cylindrical Penning trap at 50 mK using a 4.2 K self-shielding solenoid to stabilize the magnetic field to 2 ppb/day.
  • The electron's cyclotron and spin frequencies are measured in situ, enabling the ratio νₐ/ν꜀ to determine g/2 via the relation g/2 = 1 + νₐ/ν꜀.
  • The measurement is performed blind, without knowledge of prior results or predictions, to avoid bias.
  • Axial sideband cooling is used to cool the magnetron motion, minimizing its effect on the spin and cyclotron frequency measurements.
  • The apparatus uses a low-loss microwave cavity to suppress spontaneous emission and enhance coherence of the cyclotron states.
  • Theoretical uncertainties are reduced by using exact calculations for QED coefficients up to C₈ and a numerically evaluated C₁₀, with consistency checks on the latter.

Experimental results

Research questions

  • RQ1Can the electron magnetic moment be measured with a precision 2.2 times better than the previous 14-year benchmark?
  • RQ2To what extent does the new measurement improve the test of the Standard Model's prediction for g/2, given the current discrepancy in α measurements?
  • RQ3How precisely can the fine structure constant α be extracted from the electron g/2 measurement and SM theory, and how does it compare to direct α measurements?
  • RQ4What are the implications for physics beyond the Standard Model if the g/2 measurement uncertainty is reduced further, especially in light of the muon g-2 anomaly?
  • RQ5Can the experimental setup achieve sufficient field stability and low decoherence to enable a future positron g-2 measurement with 40× improved CPT symmetry test?

Key findings

  • The electron magnetic moment is measured as −μ/μ_B = g/2 = 1.00115965218059(13), with a relative uncertainty of 1.3 parts in 10^13.
  • The measurement is 2.2 times more precise than the previous 14-year benchmark value and is consistent with it.
  • The agreement between the measured g/2 and the SM prediction is at the level of 1 part in 10^12, representing the most precise confrontation of theory and experiment for any elementary particle property.
  • The new measurement yields α⁻¹ = 137.035999166(15) [0.11 ppb], with an uncertainty ten times smaller than the current discrepancy between the two most precise α measurements.
  • The result differs by 2.1σ from the Paris Rb measurement and 3.9σ from the Berkeley Cs measurement of α, suggesting the discrepancy may be resolved by improved α measurements.
  • The measurement implies an upper bound on electron substructure: Rₑ < 1.4×10⁻¹⁹ m and constituent mass m* > 1.4 TeV/c² if the uncertainty were reduced to match the current measurement precision.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.