Skip to main content
QUICK REVIEW

[Paper Review] Note on transformation to general curvilinear coordinates for Maxwell's curl equations (Is the magnetic field vector axial?)

Dzmitry M. Shyroki|ArXiv.org|Jul 3, 2003
Electromagnetic Simulation and Numerical MethodsEngineering7 references4 citations
TL;DR

This paper argues that Maxwell's equations are more consistently formulated in general curvilinear coordinates when the magnetic field **H** and magnetic flux density **B** are treated as polar (true) vectors rather than axial (pseudo) vectors. The key contribution is that the widely used perfectly matched layer (PML) method in computational electrodynamics only works correctly under this 'pure polar' formulation, as the standard axial-vector convention leads to incompatible complex-coordinate scaling in PMLs, undermining numerical stability and accuracy in simulations of waveguides and resonators.

ABSTRACT

Arguments for H and B to be considered `axial', or pseudo vectors, are revisited. As a point against, we examine the complex-coordinate method for numerical grid truncation and mode loss analysis proved very successful in computational electrodynamics. This method is not compatible with convention that H and B are axial.

Motivation & Objective

  • To resolve the longstanding ambiguity in the transformation behavior of H and B under improper coordinate transformations.
  • To investigate the compatibility of the standard axial-vector convention for H and B with complex-coordinate methods used in computational electrodynamics.
  • To demonstrate that the 'pure polar' formulation of Maxwell's equations is necessary for consistent implementation of perfectly matched layers (PMLs).
  • To show that the PML method, essential for simulating open-boundary electromagnetic problems, fails under the conventional axial-vector treatment of H and B.
  • To provide a consistent framework for curvilinear coordinate transformations in Maxwell's equations that preserves physical accuracy in numerical simulations.

Proposed method

  • Derives Maxwell's equations in general curvilinear coordinates using a tensorial, kernel-index notation that distinguishes between true vectors and pseudo vectors via the Levi-Civita symbol.
  • Introduces a 'pure polar' formulation where H and B transform as ordinary vectors under coordinate inversion, contrasting with the standard axial-vector convention.
  • Applies complex-coordinate scaling to model perfectly matched layers (PMLs), deriving the required permittivity and permeability tensors in the PML region.
  • Compares the resulting PML formulations under the 'pure polar' and 'polar-axial' conventions, showing that only the former yields the standard PML tensor (18s).
  • Validates the approach numerically by simulating the fundamental mode of a step-index fiber using finite-difference frequency-domain methods on Cartesian and polar grids.
  • Uses boundary conditions derived from the pure polar formulation to correctly classify even and odd modes in symmetric waveguides, matching physical expectations.

Experimental results

Research questions

  • RQ1Does the conventional axial-vector treatment of H and B remain consistent under general curvilinear coordinate transformations?
  • RQ2Can the widely used complex-coordinate PML method be consistently derived from Maxwell's equations if H and B are treated as axial vectors?
  • RQ3What is the impact of the H/B vector type convention on the accuracy of numerical simulations in waveguides and resonators?
  • RQ4Is there a formulation of Maxwell's equations in curvilinear coordinates that preserves compatibility with the PML method while avoiding pseudo-vector complications?
  • RQ5How do the mode classification and field behavior in symmetric systems differ between the polar-axial and pure polar formulations?

Key findings

  • The standard PML formulation (18s) is only compatible with the 'pure polar' formulation of Maxwell's equations, not with the conventional 'polar-axial' formulation.
  • Under the axial-vector convention, the PML requires a modified tensor (18v) that differs fundamentally from the standard PML, leading to numerical instability and mode errors.
  • Numerical simulations show that PMLs based on the pure polar formulation yield significantly lower mode index errors than those based on the polar-axial convention, especially on non-Cartesian grids.
  • The pure polar formulation correctly reproduces the physical boundary conditions for perfect electric conductors in nonorthogonal coordinates, such as E₁ = 0 and H₂ = H₃ = 0 at x¹ = 0.
  • The pure polar formulation leads to identical mode classification in symmetric waveguides and resonators as the conventional approach, proving equivalence in physical predictions despite different mathematical treatment.
  • The complex-coordinate scaling method used in PMLs fails to recover the correct tensor form when H and B are treated as axial vectors, invalidating the method's foundation in that convention.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.