[Paper Review] Performance of Differential Protection Applied to Collector Cables of Offshore Wind Farms with MMC-HVDC Transmission

Moisés J. B. B. Davi, F. V. Lopes|arXiv (Cornell University)|Jan 23, 2026
HVDC Systems and Fault ProtectionEngineering0 citations
TL;DR

This study evaluates conventional and sequence-based differential protections for offshore wind farm collector cables connected via MMC-HVDC, using PSCAD/EMTDC to assess internal and external faults under various control strategies of inverter-based resources. It shows conventional phase-current differential protections may miss internal faults when negative-sequence currents are suppressed, while sequence-based schemes offer improved sensitivity in many scenarios.

ABSTRACT

The ongoing global transition towards low-carbon energy has propelled the integration of offshore wind farms, which, when combined with Modular Multilevel Converter-based High-Voltage Direct Current (MMC-HVDC) transmission, present unique challenges for power system protection. In collector cables connecting wind turbines to offshore MMC, both ends are supplied by Inverter-Based Resources (IBRs), which modify the magnitude and characteristics of fault currents. In this context, this paper investigates the limitations of conventional differential protection schemes under such conditions and compares them with enhanced strategies that account for sequence components. Using electromagnetic transient simulations of a representative offshore wind farm modeled in PSCAD/EMTDC software, internal and external fault scenarios are assessed, varying fault types and resistances. The comparative evaluation provides insights into the sensitivity and selectivity of differential protection and guides a deeper conceptual understanding of the evolving protection challenges inherent to future converter-dominated grids.

Motivation & Objective

  • Motivate robust protection for collector cables in converter-dominated offshore grids.
  • Assess how IBR control strategies affect fault currents and differential protection performance.
  • Compare conventional phase-current differential protection with negative- and zero-sequence based schemes.
  • Provide insights to guide protection design for MMC-HVDC offshore wind connections.

Proposed method

  • Model a realistic two-cluster offshore wind farm (450 MVA per cluster) connected via MMC-HVDC in PSCAD/EMTDC.
  • Simulate internal and external faults on the collector cable with multiple fault types (AG, AB, ABG, ABC, PP, PPG, PPP) and fault resistances (R1–R4 as specified).
  • Implement two OMMC control scenarios: C1 (forced suppression of negative-sequence current) and C2 (negative-sequence current not suppressed).
  • Evaluate differential protections 87L, 87Q, and 87G using operating and restraint quantities as defined (I_OP and I_RST) for phase, negative-sequence, and zero-sequence components.
  • Analyze convergence points of differential elements 50 ms after fault initiation to assess sensitivity and selectivity.
Figure 1: Test system.
Figure 1: Test system.

Experimental results

Research questions

  • RQ1How do internal fault currents behave under MMC-HVDC with IBR suppression of negative-sequence currents?
  • RQ2Can conventional phase-current differential protection reliably detect internal faults in collector cables of offshore MMC-HVDC systems?
  • RQ3Do negative- and zero-sequence-based differential protections improve sensitivity for common fault types?
  • RQ4How do transformer winding configurations and zero-sequence paths influence differential protection performance for ground faults?
  • RQ5What are the impacts of external faults on the selectivity of differential protections in this topology?

Key findings

  • Conventional phase-current differential protections may lack sensitivity to internal faults when negative-sequence currents are suppressed by OMMC and wind turbines (C1).
  • When C2 is used (or when negative-sequence currents are not suppressed), all evaluated differential elements can operate satisfactorily for internal faults, though sensitivity varies by fault type and resistance.
  • Negative- and zero-sequence differential protections (87Q, 87G) improve sensitivity in some PG/PP/ABG/ABC scenarios, but can still be compromised under C1 depending on the fault and transformer zero-sequence path.
  • For external faults, none of the evaluated IBR control strategies caused spurious operations, indicating good selectivity for external faults in the collector cable under study.
  • The zero-sequence path and transformer winding connections crucially influence the success of differential protections for ground faults, highlighting the role of network topology in protection design.