Skip to main content
QUICK REVIEW

[Paper Review] Phase Retrieval From the Magnitudes of Affine Linear Measurements

Gao Bing, Qiyu Sun|arXiv (Cornell University)|Aug 22, 2016
Advanced X-ray Imaging TechniquesPhysics and Astronomy14 references4 citations
TL;DR

This paper introduces and analyzes affine phase retrieval, where signals are recovered from magnitudes of affine linear measurements (i.e., linear measurements with added constants). It establishes necessary and sufficient conditions for affine phase retrievability, shows that only 3d measurements are needed in the complex case—significantly fewer than the 4d−4 required in standard phase retrieval—and proves that affine phase retrieval eliminates the unimodular ambiguity present in standard phase retrieval.

ABSTRACT

In this paper, we consider the phase retrieval problem in which one aims to recover a signal from the magnitudes of affine measurements. Let $\{{\mathbf a}_j\}_{j=1}^m \subset {\mathbb H}^d$ and ${\mathbf b}=(b_1, \ldots, b_m)^ op\in{\mathbb H}^m$, where ${\mathbb H}={\mathbb R}$ or ${\mathbb C}$. We say $\{{\mathbf a}_j\}_{j=1}^m$ and $\mathbf b$ are affine phase retrievable for ${\mathbb H}^d$ if any ${\mathbf x}\in{\mathbb H}^d$ can be recovered from the magnitudes of the affine measurements $\{|+b_j|,\, 1\leq j\leq m\}$. We develop general framework for affine phase retrieval and prove necessary and sufficient conditions for $\{{\mathbf a}_j\}_{j=1}^m$ and $\mathbf b$ to be affine phase retrievable. We establish results on minimal measurements and generic measurements for affine phase retrieval as well as on sparse affine phase retrieval. In particular, we also highlight some notable differences between affine phase retrieval and the standard phase retrieval in which one aims to recover a signal $\mathbf x$ from the magnitudes of its linear measurements. In standard phase retrieval, one can only recover $\mathbf x$ up to a unimodular constant, while affine phase retrieval removes this ambiguity. We prove that unlike standard phase retrieval, the affine phase retrievable measurements $\{{\mathbf a}_j\}_{j=1}^m$ and $\mathbf b$ do not form an open set in ${\mathbb H}^{m imes d} imes {\mathbb H}^m$. Also in the complex setting, the standard phase retrieval requires $4d-O(\log_2d)$ measurements, while the affine phase retrieval only needs $m=3d$ measurements.

Motivation & Objective

  • To develop a general mathematical framework for phase retrieval using affine linear measurements, which include constant shifts.
  • To determine necessary and sufficient conditions under which a set of affine measurements uniquely recovers any signal up to a global phase.
  • To investigate minimal measurement requirements and generic measurement configurations for affine phase retrieval.
  • To explore sparse signal recovery in the affine phase retrieval setting.
  • To compare and contrast affine phase retrieval with standard phase retrieval, particularly regarding measurement complexity and unimodular ambiguity.

Proposed method

  • Formalize affine phase retrieval as recovering a signal x ∈ ℍ^d from |⟨a_j, x⟩ + b_j|, where a_j ∈ ℍ^d and b_j ∈ ℍ.
  • Define affine phase retrievability using the measurement matrix A and vector b, establishing conditions under which x can be uniquely recovered.
  • Use algebraic geometry and frame theory to derive necessary and sufficient conditions for affine phase retrievability.
  • Analyze the minimal number of measurements required, proving that m = 3d suffices in the complex case.
  • Establish that the set of affine phase retrievable measurements is not open in ℍ^{m×d} × ℍ^m, unlike in standard phase retrieval.
  • Apply Lipschitz stability analysis to show that the measurement map is stable under small perturbations, though not bi-Lipschitz.

Experimental results

Research questions

  • RQ1What conditions on the measurement vectors {a_j} and shifts {b_j} ensure that a signal x ∈ ℍ^d can be uniquely recovered from |⟨a_j, x⟩ + b_j|?
  • RQ2What is the minimal number of affine measurements required for phase retrieval in real and complex settings?
  • RQ3How does the inclusion of affine shifts eliminate the unimodular ambiguity present in standard phase retrieval?
  • RQ4Are the sets of affine phase retrievable measurements open in the parameter space ℍ^{m×d} × ℍ^m?
  • RQ5Can sparse signals be recovered efficiently using affine phase retrieval, and what are the measurement requirements in such cases?

Key findings

  • Affine phase retrieval eliminates the unimodular ambiguity: signals can be recovered exactly, not just up to a global phase.
  • In the complex case, only m = 3d measurements are required for phase retrieval, which is fewer than the 4d−4 required in standard phase retrieval.
  • The set of affine phase retrievable measurements is not open in ℍ^{m×d} × ℍ^m, a key difference from standard phase retrieval.
  • For generic measurements, affine phase retrieval is possible with m = 3d measurements in the complex case.
  • The measurement map M_{A,b} is stable under small perturbations, satisfying a lower Lipschitz bound of the form ||M_{A,b}(x) - M_{A,b}(y)|| ≥ c / (1 + ||x|| + ||y||) ||x - y||.
  • The map M_{A,b} is not bi-Lipschitz, as shown by constructing sequences where the ratio of output to input distance tends to zero as the signal norm increases.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.