[Paper Review] Post-injection aseismic slip as a mechanism for the delayed triggering of seismicity
This study proposes that post-injection aseismic slip propagates as pulse-like ruptures in 3D fault systems, persisting long after fluid injection ceases. Using a hydro-mechanical model, it demonstrates that critically stressed faults can sustain slip propagation for orders of magnitude longer than injection duration, with ruptures reaching nearly double their shut-in size—offering a mechanism for delayed, distal seismicity in geo-energy operations.
Injection-induced aseismic slip plays an important role in a broad range of human-made and natural systems, from the exploitation of geo-resources to the understanding of earthquakes. Recent studies have shed light on how aseismic slip propagates in response to continuous fluid injections. Yet much less is known about the response of faults after the injection of fluids has stopped. In this work, we investigate via an hydro-mechanical model the propagation and ultimate arrest of aseismic slip during the so-called post-injection stage. We show that after shut-in, fault slip propagates in pulse-like mode. The conditions that control the propagation as a pulse and notably when and where the ruptures arrest are fully established. In particular, critically-stressed faults can host rupture pulses that propagate for several orders of magnitude the injection duration and reach up to nearly double the size of the ruptures at the moment of shut-in. We consequently argue that the persistent stressing of increasingly larger rock volumes caused by post-injection aseismic slip is a plausible mechanism for the triggering of post-injection seismicity -- a critical issue in the geo-energy industry. We discuss evidence that supports this mechanism based on documented cases of post-injection-induced seismicity.
Motivation & Objective
- To understand the propagation and arrest mechanisms of aseismic slip during the post-injection phase after fluid injection stops.
- To assess whether post-injection aseismic slip can explain the delayed occurrence of seismicity observed in field cases.
- To quantify the spatiotemporal evolution of fault slip and stress redistribution after shut-in in 3D hydro-mechanical systems.
- To evaluate the implications of this mechanism for seismic risk management in geo-energy projects, particularly under traffic light systems.
- To establish a physics-based framework for post-injection aseismic slip as a driver of distal and delayed seismic events.
Proposed method
- Development of a 3D hydro-mechanical model coupling fluid flow and fault slip dynamics using a boundary element method.
- Implementation of a constant friction coefficient to ensure unconditionally stable slip, representing a conservative upper bound on rupture propagation.
- Simulation of fluid injection followed by shut-in, tracking the evolution of slip and stress fields over time.
- Use of the stress-injection parameter 𝒯 to quantify fault criticality and its influence on post-injection slip propagation.
- Analysis of rupture propagation in pulse-like mode, with focus on run-out distance and arrest time.
- Comparison with known field cases of post-injection seismicity to validate the proposed mechanism.
Experimental results
Research questions
- RQ1How does aseismic slip propagate after fluid injection ceases in 3D fault systems?
- RQ2What controls the arrest of post-injection aseismic ruptures in terms of timing and spatial extent?
- RQ3To what extent can post-injection aseismic slip stress distant fault patches and trigger seismicity?
- RQ4How does fault criticality, quantified by the stress-injection parameter 𝒯, influence the duration and size of post-injection slip events?
- RQ5Can this mechanism explain observed cases of delayed seismicity following injection shutdown in geothermal and hydrocarbon operations?
Key findings
- Post-injection aseismic slip propagates in pulse-like mode, with rupture fronts advancing even after injection has stopped.
- Ruptures on critically stressed faults can propagate for up to several orders of magnitude longer than the injection duration.
- Maximum rupture run-out distances can reach nearly double the size of the rupture at the time of shut-in.
- The persistent stressing of increasingly larger rock volumes by post-injection slip provides a plausible mechanism for delayed seismicity.
- The mechanism is most effective for faults with high stress-injection parameter 𝒯, indicating critical stress state.
- The model represents an upper bound on rupture propagation, as it neglects fracture energy dissipation and frictional healing, both of which would otherwise shorten propagation.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.