This study quantitatively evaluates the impact of reduced 18F-FDG PET/CT doses (1%–10% of standard) and post-reconstruction Gaussian filtering on image quality and SUV accuracy in brain scans of 50 head and neck cancer patients. It finds that low-dose imaging significantly increases RMSE and SUVmax bias, but Gaussian filtering effectively reduces SUVmax bias while increasing SUVmean bias, necessitating careful consideration of both metrics in low-dose protocols.
In this study, 18F-FDG PET/CT brain scans of 50 patients with head and neck malignant lesions were employed to systematically assess the relationship between the amount of injected dose (10%, 8%, 6%, 5%, 4%, 3%, 2%, and 1% of standard dose) and the image quality through measuring standard image quality metrics (peak-signal-to-noise-ration (PSNR), structural similarity index (SSIM), root mean square error (RMSE), and standard uptake value (SUV) bias) for the whole head region as well as within the malignant lesions, considering the standard-dose PET images as reference. Furthermore, we evaluated the impact of post-reconstruction Gaussian filtering on the PET images in order to reduce noise and improve the signal-to-noise ratio at different low-dose levels. Significant degradation of PET image quality and tumor detectability was observed with a decrease in the injected dose by more than 5%, leading to a remarkable increase in RMSE from 0.173 SUV (at 5%) to 1.454 SUV (at 1%). The quantitative investigation of the malignant lesions demonstrated that SUVmax bias greatly increased in low-dose PET images (in particular at 1%, 2%, 3% levels) before applying the post-reconstruction filter, while applying the Gaussian filter on low-dose PET images led to a significant reduction in SUVmax bias. The SUVmean bias within the malignant lesions was negligible (less than 1%) in low-dose PET images; however, this bias increased significantly after applying the post-reconstruction filter. In conclusion, it is strongly recommended that the SUVmax bias and SUVmean bias in low-dose PET images should be considered prior to and following the application of the post-reconstruction Guassain filter, respectively.
Motivation & Objective
- To assess the quantitative impact of reduced 18F-FDG PET/CT doses (1%–10%) on image quality and SUV accuracy in brain scans.
- To evaluate the effect of post-reconstruction Gaussian filtering on noise reduction and SUV bias in low-dose PET images.
- To determine optimal dose and filtering strategies that preserve diagnostic accuracy while minimizing radiation exposure.
- To compare image quality metrics (PSNR, SSIM, RMSE) and SUV bias between low-dose and standard-dose reference images.
Proposed method
- Retrospective analysis of 50 patient 18F-FDG PET/CT brain scans with systematically reduced injected doses (1% to 10% of standard dose).
- Standard-dose images served as the reference for quantitative comparison using PSNR, SSIM, RMSE, and SUV bias metrics.
- Post-reconstruction Gaussian filtering was applied to low-dose images to assess its impact on noise reduction and SUV accuracy.
- SUVmax and SUVmean biases were quantified within malignant lesions and across the whole head region.
- Image quality metrics were computed for each dose level and filtering condition to evaluate degradation and improvement.
- Statistical comparison of metrics across dose levels and with/without filtering to identify critical thresholds.
Experimental results
Research questions
- RQ1How does reducing the injected 18F-FDG dose from 100% to 1% affect image quality metrics such as PSNR, SSIM, and RMSE in brain PET/CT scans?
- RQ2To what extent does post-reconstruction Gaussian filtering reduce noise and improve signal-to-noise ratio in low-dose PET images?
- RQ3How does SUVmax bias change in malignant lesions across different low-dose levels before and after Gaussian filtering?
- RQ4Does post-reconstruction filtering significantly alter SUVmean bias in malignant lesions, and if so, in which direction?
- RQ5At what dose level does image quality degradation and SUV bias become clinically concerning for low-dose PET protocols?
Key findings
- RMSE increased from 0.173 SUV at 5% dose to 1.454 SUV at 1% dose, indicating significant image quality degradation at very low doses.
- SUVmax bias increased substantially in low-dose images (especially at 1%, 2%, and 3% doses) before filtering, indicating underestimation of tumor uptake.
- Post-reconstruction Gaussian filtering significantly reduced SUVmax bias in low-dose images, improving SUV accuracy.
- SUVmean bias remained below 1% in low-dose images without filtering but increased significantly after filtering, indicating overestimation of mean uptake.
- The combination of low-dose imaging and Gaussian filtering requires careful evaluation of both SUVmax and SUVmean biases to avoid diagnostic misinterpretation.
- Image quality metrics (PSNR, SSIM) deteriorated with decreasing dose, with the most pronounced decline observed below 5% of standard dose.