[Paper Review] Regional accuracy of ZTE-based attenuation correction in static and dynamic brain PET/MR
This study evaluates zero-echo-time (ZTE)-based attenuation correction (ZTEAC) in brain PET/MR, demonstrating its superior quantitative accuracy over the default atlas-based AC (AtlasAC) in both static [18F]FDG and dynamic [18F]PE2I scans. ZTEAC achieves near-CTAC-level accuracy with mean regional bias of ±0.1% in static scans and ±1.5% in dynamic binding potential (BPnd), significantly outperforming AtlasAC, which shows up to -31.6% to +16.6% bias and systematic cranio-caudal gradients.
Accurate MR-based attenuation correction (MRAC) is essential for quantitative PET/MR imaging of the brain. In this study, we analyze the regional bias caused by MRAC based on Zero-Echo-Time MR images (ZTEAC) compared to CT-based AC (CTAC) in static and dynamic PET imaging. In addition the results are compared to the performance of the current default Atlas-based AC (AtlasAC) implemented in the GE SIGNA PET/MR. Methods: Thirty static [18F]FDG and 11 dynamic [18}F]PE2I acquisitions from a GE SIGNA PET/MR were reconstructed using ZTEAC (using a research tool, GE Healthcare), single-subject AtlasAC (the current default AC in GE's SIGNA PET/MR) and CTAC (from a PET/CT acquisition of the same day). In the 30 static [18F]FDG reconstructions, the bias caused by ZTEAC and AtlasAC in the mean uptake of 85 anatomical volumes of interest (VOIs) of the Hammers' atlas was analyzed in PMOD. For the 11 dynamic [18}F]PE2I reconstructions, the bias caused by ZTEAC and AtlasAC in the non displaceable binding potential BPnd in the striatum was calculated with cerebellum as the reference region and a simplified reference tissue model. Results: The regional bias caused by ZTEAC in the static [18F]FDG reconstructions ranged from -8.0% to +7.7% (mean 0.1%, SD 2.0%). For AtlasAC this bias ranged from -31.6% to +16.6% (mean -0.4%, SD 4.3%). The bias caused by AtlasAC showed a clear gradient in the cranio-caudal direction (-4.2% in the cerebellum, +6.6% in the left superior frontal gyrus). The bias in the striatal BPnd for the [18F]PE2I reconstructions ranged from -0.8% to +4.8% (mean 1.5%, SD 1.4%) using ZTEAC and from -0.6% to +9.4% using AtlasAC (mean 4.2%, SD 2.6%). Conclusion: ZTEAC provides excellent quantitative accuracy for static and dynamic brain PET/MR, comparable to CTAC, and is clearly superior to the default AtlasAC currently implemented in the GE SIGNA PET/MR.
Motivation & Objective
- To evaluate the regional quantitative accuracy of ZTE-based attenuation correction (ZTEAC) in brain PET/MR compared to CT-based AC (CTAC) and the default AtlasAC in clinical scanners.
- To assess whether ZTEAC maintains high accuracy in dynamic PET studies, particularly for kinetic modeling parameters like non-displaceable binding potential (BPnd).
- To identify and quantify systematic biases introduced by current clinical AtlasAC methods in brain PET/MR, especially in regions with high bone attenuation.
- To validate ZTEAC as a robust, patient-specific alternative to atlas-based methods, particularly in patients with abnormal brain anatomy.
Proposed method
- Acquired 30 static [18F]FDG and 11 dynamic [18F]PE2I PET/MR scans on a GE SIGNA PET/MR scanner.
- Reconstructed all data using three attenuation correction methods: ZTEAC (research tool), AtlasAC (default GE implementation), and CTAC (ground truth from same-day PET/CT).
- Used Hammers' atlas to define 85 anatomical volumes of interest (VOIs) for regional bias analysis in static [18F]FDG scans.
- Applied the simplified reference tissue model with cerebellum as reference region to calculate BPnd in striatal regions for dynamic [18F]PE2I scans.
- Quantified bias as the percentage deviation of ZTEAC and AtlasAC from CTAC in mean standardized uptake values (SUVmean) and BPnd across VOIs.
- Performed statistical analysis to assess significance of bias differences and correlation with anatomical location.
Experimental results
Research questions
- RQ1How does ZTE-based attenuation correction compare to CT-based AC in terms of regional quantitative accuracy in static brain PET/MR?
- RQ2What is the magnitude and spatial distribution of bias in BPnd when using ZTEAC versus AtlasAC in dynamic [18F]PE2I PET/MR studies?
- RQ3Does the default AtlasAC method in the GE SIGNA PET/MR introduce systematic regional biases in brain PET quantification, and if so, where and how severe are they?
- RQ4How does ZTEAC perform in dynamic kinetic modeling compared to CTAC, particularly in regions with high tracer binding such as the striatum?
- RQ5Can ZTEAC reliably replace CTAC for quantitative brain PET/MR without relying on anatomical atlases, especially in patients with abnormal brain anatomy?
Key findings
- ZTEAC achieved a mean regional bias of 0.1% (SD 2.0%) across 85 VOIs in static [18F]FDG scans, with a range of -8.0% to +7.7%, demonstrating near-CTAC accuracy.
- AtlasAC showed a significantly higher mean bias of -0.4% (SD 4.3%) with a pronounced cranio-caudal gradient, ranging from -4.2% in the cerebellum to +6.6% in the left superior frontal gyrus.
- In dynamic [18F]PE2I studies, ZTEAC yielded a mean BPnd bias of 1.5% (SD 1.4%), ranging from -0.8% to +4.8%, indicating excellent quantitative accuracy.
- AtlasAC introduced a systematic overestimation of BPnd in the striatum, with a mean bias of 4.2% (SD 2.6%), ranging from -0.6% to +9.4%, particularly affecting the caudate nucleus and putamen.
- ZTEAC reduced the AtlasAC-induced overestimation of BPnd by approximately half, demonstrating superior robustness in kinetic modeling.
- The performance of ZTEAC was comparable to state-of-the-art methods in prior multi-center studies, with similar bias ranges and standard deviations, indicating clinical viability.