[Paper Review] ROSAT PSPC Observations of the Richest ($R \geq 2$) ACO Clusters
This study analyzes ROSAT PSPC pointed observations of 150 optically rich (R ≥ 2) ACO clusters to assess X-ray properties, detectability, and contamination in the ACO catalog. It finds that 35% of southern ACO clusters and 20% of Abell clusters suffer from significant richness overestimation due to interloping galaxies, with X-ray luminosity below 3.0×10⁴³ erg s⁻¹ serving as a key diagnostic for contamination.
We have compiled an X-ray catalog of optically selected rich clusters of galaxies observed by the PSPC during the pointed GO phase of the ROSAT mission. This paper contains a systematic X-ray analysis of 150 clusters with an optical richness classification of $R \geq 2$ from the ACO catalog (Abell, Corwin, and Olowin 1989). All clusters were observed within 45' of the optical axis of the telescope during pointed PSPC observations. For each cluster, we calculate: the net 0.5-2.0 keV PSPC count rate (or $4 σ$ upper limit) in a 1 Mpc radius aperture, 0.5-2.0 keV flux and luminosity, bolometric luminosity, and X-ray centroid. The cluster sample is then used to examine correlations between the X-ray and optical properties of clusters, derive the X-ray luminosity function of clusters with different optical classifications, and obtain a quantitative estimate of contamination (i.e, the fraction of clusters with an optical richness significantly overestimated due to interloping galaxies) in the ACO catalog.
Motivation & Objective
- To systematically analyze X-ray properties of 150 optically rich ACO clusters (R ≥ 2) observed by ROSAT PSPC during the GO phase.
- To quantify the detection rate of clusters based on optical richness and Bautz-Morgan type, assessing how optical properties affect X-ray detectability.
- To derive the X-ray luminosity function for different optical sub-samples and compare northern (Abell) and southern ACO clusters.
- To estimate the fraction of clusters with overestimated richness due to contamination by interloping galaxies using X-ray luminosity as a proxy.
- To investigate environmental differences between low- and high-luminosity clusters, particularly in supercluster environments.
Proposed method
- Compiled a catalog of 150 ACO clusters (R ≥ 2) from the ACO catalog that were observed by ROSAT PSPC during the pointed GO phase.
- Calculated net 0.5–2.0 keV count rates, fluxes, luminosities, and X-ray centroids for each cluster within a 1 Mpc aperture.
- Used long integration times (typical ~10,000 s) to achieve low X-ray detection thresholds (~3×10⁴³ erg s⁻¹), comparable to X-ray luminous groups.
- Compared X-ray fluxes from pointed PSPC data with those from the ROSAT All-Sky Survey (RASS) for overlapping clusters.
- Applied statistical methods to derive both parametric and nonparametric X-ray luminosity functions for the full sample and sub-samples.
- Quantified contamination by comparing the fraction of clusters with L(0.5–2.0 keV) < 3.0×10⁴³ erg s⁻¹ to the expected richness distribution, assuming such systems are likely contaminated.
Experimental results
Research questions
- RQ1What is the X-ray detection rate of optically rich ACO clusters (R ≥ 2) in ROSAT PSPC pointed observations, and how does it vary with optical morphology (Bautz-Morgan type)?
- RQ2How do the X-ray luminosity functions of Abell and southern ACO clusters compare, and what does this imply about the optical richness classification in each catalog?
- RQ3To what extent is the optical richness of ACO clusters overestimated due to contamination by interloping galaxies, and how can this be quantified using X-ray luminosity?
- RQ4What is the environmental context of low X-ray luminosity clusters, and how does it differ from that of X-ray luminous clusters?
- RQ5Is there a systematic offset in optical richness classification between the northern (Abell) and southern ACO catalogs, and if so, what is its magnitude?
Key findings
- The overall serendipitous detection rate for R ≥ 2 ACO clusters is 76%, but it drops to 71% for Bautz-Morgan Type II, II-III, and III clusters, while all Type I and I-II clusters are detected.
- 83% of Abell clusters are detected at z > 0.1, compared to only 60% of southern ACO clusters, indicating a detection bias linked to optical selection methods.
- The X-ray luminosity function of R ≥ 2 Abell clusters is inconsistent with that of southern ACO clusters, but becomes consistent when comparing R ≥ 2 Abell clusters with R ≥ 3 southern ACO clusters.
- The analysis indicates a systematic offset of approximately one richness class in the southern ACO catalog, with 35% of southern ACO clusters and 20% of Abell clusters suffering from significant contamination (defined as L(0.5–2.0 keV) < 3.0×10⁴³ erg s⁻¹).
- 70% of low X-ray luminosity clusters (L < 3.0×10⁴³ erg s⁻¹) have a neighboring ACO cluster within 1° and Δm₁₀ ≤ 0.2, compared to only 35% of more luminous clusters, indicating higher environmental density for low-luminosity systems.
- The use of a global rather than local galaxy background in the southern ACO catalog likely explains the higher richness classification and greater contamination compared to the Abell catalog.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.