Skip to main content
QUICK REVIEW

[Paper Review] SAMPIC: a readout chip for fast timing detectors in particle physics and medical imaging

C. Royon|arXiv (Cornell University)|Mar 16, 2015
Radiation Therapy and DosimetryMedicine1 references3 citations
TL;DR

SAMPIC is a low-cost, 16-channel readout chip designed for picosecond-timing applications in particle physics and medical imaging. It captures full detector waveforms using analog memory and a 64-step sampling system, achieving a timing resolution of 4 ps per channel, with demonstrated performance of 30 ps in Si detector tests and potential for 10 ps resolution in future PET systems.

ABSTRACT

We describe the new fast timing readout chip SAMPIC developed in CEA Saclay and in LAL Orsay (France) as well as the results of differents tests performed using that chip.

Motivation & Objective

  • Develop a low-cost, high-precision timing readout chip for fast timing detectors in particle physics and medical imaging.
  • Overcome limitations of traditional TDCs that rely on discriminators, which introduce jitter and degrade timing resolution.
  • Enable full waveform acquisition to allow offline optimization of timing resolution and signal characterization.
  • Reduce dead time per channel to improve throughput, especially for high-luminosity applications like LHC forward physics.
  • Facilitate large-scale deployment in applications such as PET imaging by reducing cost to ~10 euros per channel.

Proposed method

  • Use a waveform-based TDC approach by sampling the full analog signal shape using 64-cell analog memory per channel.
  • Implement independent trigger modes (self-triggered or external) with a discriminator only for triggering, not timing.
  • Apply a Gray counter with 6 ns step and a DLL with 150 ps resolution to assign time stamps to sampled points.
  • Use interpolation (linear or spline) between sampled points to achieve sub-picosecond resolution via offline algorithms like CFD and cross-correlation.
  • Integrate an ADC for digital conversion and support USB/Ethernet/fiber optic readout for data transfer.
  • Implement a 'ping-pong' method in future versions to reduce dead time by an order of magnitude.

Experimental results

Research questions

  • RQ1Can a full waveform sampling approach achieve sub-5 ps timing resolution without discriminator-induced jitter?
  • RQ2How does the timing resolution of SAMPIC perform across varying signal amplitudes and delays?
  • RQ3What is the achievable timing resolution when SAMPIC is interfaced with real fast detectors like Si or diamond?
  • RQ4To what extent can the chip’s dead time be reduced through firmware and hardware optimizations like the ping-pong method?
  • RQ5Can SAMPIC enable real-time image reconstruction in PET by suppressing fake coincidences through 10 ps timing precision?

Key findings

  • SAMPIC achieves a timing resolution of approximately 4 ps per channel when using offline cross-correlation or CFD algorithms on identical signals.
  • The timing resolution remains flat across different signal delays, with an RMS of about 5 ps for time difference measurements between two channels.
  • Signal amplitude must exceed 450 mV to achieve the best timing resolution of ~4 ps, with performance degrading below this threshold.
  • In tests with fast Si detectors, SAMPIC achieved a time resolution of 30 ps, limited by the detector response rather than the chip.
  • The chip demonstrates low noise (1 mV RMS average, up to 1.5 mV in worst-case cells) and crosstalk below 1% between adjacent channels.
  • Future versions aim to reduce dead time from ~1 μs to ~0.1 μs using the 'ping-pong' method and analog buffering, enabling higher data throughput.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.