Skip to main content
QUICK REVIEW

[Paper Review] Scheme for generation of fully-coherent, TW power level hard X-ray pulses from baseline undulators at the European X-ray FEL

Gianluca Geloni, Vitali Kocharyan|arXiv (Cornell University)|Jul 16, 2010
Particle Accelerators and Free-Electron LasersEngineering3 references25 citations
TL;DR

This paper proposes a cascade self-seeding scheme with wake monochromators and undulator tapering in the baseline SASE2 undulator at the European XFEL to generate fully-coherent, TW peak power, hard X-ray pulses at 0.15 nm wavelength. The method achieves three orders of magnitude higher peak brightness than LCLS, enabling unprecedented applications in single biomolecule imaging and inelastic scattering.

ABSTRACT

The most promising way to increase the output power of an X-ray FEL (XFEL) is by tapering the magnetic field of the undulator. Also, significant increase in power is achievable by starting the FEL process from a monochromatic seed rather than from noise. This report proposes to make use of a cascade self-seeding scheme with wake monochromators in a tunable-gap baseline undulator at the European XFEL to create a source capable of delivering coherent radiation of unprecedented characteristics at hard X-ray wavelengths. Compared with SASE X-ray FEL parameters, the radiation from the new source has three truly unique aspects: complete longitudinal and transverse coherence, and a peak brightness three orders of magnitude higher than what is presently available at LCLS. Additionally, the new source will generate hard X-ray beam at extraordinary peak (TW) and average (kW) power level. The proposed source can thus revolutionize fields like single biomolecule imaging, inelastic scattering and nuclear resonant scattering. The self-seeding scheme with the wake monochromator is extremely compact, and takes almost no cost and time to be implemented. The upgrade proposed in this paper could take place during the commissioning stage of the European XFEL, opening a vast new range of applications from the very beginning of operations. We present feasibility study and examplifications for the SASE2 line of the European XFEL.

Motivation & Objective

  • Address the need for higher photon flux and full longitudinal coherence in X-ray FELs for advanced applications like single biomolecule imaging.
  • Overcome limitations of SASE FELs, which produce incoherent radiation with limited spectral purity and peak brightness.
  • Enable high-brightness, fully-coherent X-ray pulses at hard X-ray wavelengths (0.15 nm) with unprecedented peak (TW) and average (kW) power levels.
  • Facilitate multi-user operation by enabling efficient, rapid beam distribution using crystal deflectors with high reflectivity and wide angular acceptance.
  • Upgrade the European XFEL during commissioning to deliver high-brightness, coherent radiation from day one of operations.

Proposed method

  • Implement a cascade self-seeding scheme using wake monochromators to monochromatize the SASE radiation at the output of the first undulator section.
  • Utilize a tunable-gap, 42-cell baseline undulator in the SASE2 line of the European XFEL to enable efficient tapering of the magnetic field along the undulator length.
  • Apply undulator tapering to increase output power by maintaining resonance as electron energy decreases, enhancing radiation field buildup through ponderomotive trapping.
  • Combine self-seeding with undulator tapering to achieve radiation bandwidth close to the Fourier transform limit, enabling full longitudinal coherence.
  • Design a multi-user beam distribution system using crystals in Bragg reflection geometry to deflect and steer the full radiation pulse with ~99% reflectivity and wide angular acceptance.
  • Ensure compatibility with the existing baseline design by using compact, low-cost wake monochromators that require minimal modifications.

Experimental results

Research questions

  • RQ1Can a self-seeding scheme with wake monochromators and undulator tapering generate fully-coherent, TW-level hard X-ray pulses at the European XFEL?
  • RQ2What is the achievable peak brightness and spectral purity when combining self-seeding with undulator tapering in a tunable-gap undulator?
  • RQ3How can a multi-user XFEL facility be efficiently operated with high-brightness, fully-coherent X-ray pulses?
  • RQ4To what extent does the self-seeding scheme improve longitudinal coherence and spectral bandwidth compared to standard SASE FELs?
  • RQ5Can this upgrade be implemented during the commissioning phase without disrupting baseline operations?

Key findings

  • The proposed scheme generates fully-coherent, 5 fs-FWHM X-ray pulses with 2×10¹² photons per pulse at 0.15 nm wavelength, achieving unprecedented peak brightness.
  • Peak brightness reaches up to 10³⁷ ph/s/mm²/mrad²/0.1% BW, representing a three-order-of-magnitude increase over current LCLS capabilities.
  • Average brightness reaches up to 10²⁸ ph/s/mm²/mrad²/0.1% BW at 0.25 nC bunch charge, enabling high-throughput multi-user operation.
  • The self-seeding scheme with wake monochromators achieves radiation bandwidth close to the Fourier transform limit, ensuring full longitudinal coherence.
  • Electron energy spread at undulator exit is approximately 2%, indicating effective capture and deceleration of electrons in the ponderomotive well during tapering.
  • The beam distribution system using Bragg-crystal deflectors can handle full pulses with ~99% reflectivity and wide angular acceptance, enabling rapid switching between multiple experiments.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.