Skip to main content
QUICK REVIEW

[Paper Review] Way to increase the user access at the LCLS baseline

Gianluca Geloni, Vitali Kocharyan|arXiv (Cornell University)|Oct 4, 2010
Particle Accelerators and Free-Electron LasersEngineering8 references7 citations
TL;DR

This paper proposes a compact, reversible setup using a 4 m magnetic chicane and insertable X-ray mirrors to enable simultaneous two-user operation at the LCLS baseline undulator by spatially separating SASE X-ray beams generated in the first and second halves of the undulator. The method allows for rapid switching between users and extends to six-user operation via fast-switching crystal deflectors, achieving monochromatic hard X-ray beams at both fundamental and second harmonic frequencies with high power and narrow bandwidth.

ABSTRACT

The LCLS beam is meant for a single user, but the baseline undulator is long enough to serve two users simultaneously. To this end, we propose a setup composed of two elements: an X-ray mirrors pair for X-ray beam deflection, and a 4 m-long magnetic chicane, which creates an offset for mirrors pair installation in the middle of the baseline undulator. The insertable mirrors pair can separate spatially the X-ray beams generated in the first and in the second half of the baseline undulator. Rapid switching of the FEL amplification process allows deactivating one half and activating another half of the undulator. As proposed elsewhere, using a kicker installed upstream of the LCLS baseline undulator and an already existing corrector in the first half of the undulator, it is possible to rapidly switch the X-ray beam from one user to another. We present simulation results for the LCLS baseline, and show that it is possible to generate two saturated SASE X-ray beams in the whole 0.8-8 keV photon energy range in the same baseline undulator. These can serve two users. Our technique does not perturb the baseline mode of operation of the LCLS undulator. Also, the magnetic chicane setup is very flexible, and can be used as a self-seeding setup too. We present simulation results for the LCLS baseline undulator with SHAB. One can produce monochromatic radiation at the 2nd harmonic as well as at the 1st. We describe an efficient way for obtaining multi-user operation at the LCLS hard X-ray FEL. To this end, a photon beam distribution system based on the use of crystals in the Bragg reflection geometry is proposed. The reflectivity of crystal deflectors can be switched fast enough by flipping the crystals with piezoelectric devices. Monochromatic hard X-rays can then be distributed among 6 independent experiments, thereby enabling 6 users to work in parallel in the near and far experimental halls.

Motivation & Objective

  • To increase user access at the LCLS baseline undulator without compromising baseline operation or incurring high cost or risk.
  • To enable simultaneous operation for two users by spatially separating SASE X-ray beams generated in different halves of the long baseline undulator.
  • To extend the capability to support up to six users in parallel by using rapidly switchable crystal deflectors in Bragg reflection geometry.
  • To demonstrate the feasibility of self-seeding with a Second Harmonic Afterburner (SHAB) for generating high-quality monochromatic radiation at both first and second harmonics.
  • To ensure the proposed system is reversible and does not interfere with standard LCLS operation, maintaining safe return to baseline mode.

Proposed method

  • Install a 4 m-long magnetic chicane after the 13th undulator segment to create a spatial offset for inserting a pair of X-ray mirrors.
  • Use the chicane to enable rapid switching of FEL amplification between the first and second halves of the undulator, allowing beam switching between two users.
  • Employ insertable X-ray mirrors in Bragg reflection geometry to spatially separate the two SASE X-ray beams generated in the two undulator halves.
  • Utilize fast-acting piezoelectric crystal deflectors to route monochromatic X-rays to six different experimental stations, with switching rates up to 100 Hz.
  • Implement a self-seeding scheme using a single crystal monochromator in the SHAB configuration to produce narrowband radiation at both fundamental and second harmonic frequencies.
  • Simulate the performance of the system using full FEL simulation tools, analyzing power, bandwidth, and stability across the 0.8–8 keV range and at 16 keV for second harmonic operation.

Experimental results

Research questions

  • RQ1Can the LCLS baseline undulator support two simultaneous SASE X-ray beams at saturation across the 0.8–8 keV range using a minimal hardware modification?
  • RQ2Is it feasible to achieve rapid, reversible switching between two users by controlling the FEL gain in different undulator segments?
  • RQ3Can a self-seeded SHAB configuration produce intense, narrowband radiation at both the first and second harmonic with a small number of undulator cells?
  • RQ4What is the maximum power and bandwidth achievable at the second harmonic using the proposed self-seeding setup with SHAB?
  • RQ5Can fast-switching crystal deflectors enable efficient, high-repetition-rate beam distribution to six independent experiments in the near and far experimental halls?

Key findings

  • Two saturated SASE X-ray beams can be generated simultaneously across the 0.8–8 keV range by activating the first and second halves of the baseline undulator in sequence using rapid switching.
  • The proposed setup allows for two-user operation with no disruption to baseline LCLS operation, as the chicane and mirrors can be retracted to restore standard mode.
  • The self-seeding scheme with SHAB produces a second harmonic output with a bandwidth of 0.007% and power levels reaching the GW range, even with only five undulator segments.
  • The first harmonic power reaches 40 GW in simulations, demonstrating high efficiency with a compact configuration using 11 out of 13 cells.
  • Crystal deflectors can be switched at 100 Hz with sub-microradian precision, enabling efficient beam distribution to six independent experiments using monochromatic radiation.
  • The system is fully reversible and safe, as the chicane can be switched off to restore baseline operation instantly, ensuring operational continuity.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.