Skip to main content
QUICK REVIEW

[Paper Review] Cost-effective way to enhance the capabilities of the LCLS baseline

Gianluca Geloni, Vitali Kocharyan|arXiv (Cornell University)|Aug 18, 2010
Advanced X-ray Imaging TechniquesPhysics and Astronomy8 references24 citations
TL;DR

This paper proposes a cost-effective single-bunch self-seeding scheme using a compact single-crystal monochromator in a 4-meter magnetic chicane to achieve Fourier-transform-limited, fully coherent X-ray pulses at the LCLS baseline. The method enables high-power (up to 100 GW), narrowband radiation, unlocking advanced capabilities such as full polarization control, crystal-based beam deflection, and femtosecond pump-probe experiments without requiring precise timing between pump and probe pulses.

ABSTRACT

This paper discusses the potential for enhancing the LCLS hard X-ray FEL capabilities. In the hard X-ray regime, a high longitudinal coherence will be the key to such performance upgrade. The method considered here to obtain high longitudinal coherence is based on a novel single-bunch self-seeding scheme exploiting a single crystal monochromator, which is extremely compact and can be straightforwardly installed in the LCLS baseline undulator. We present simulation results dealing with the LCLS hard X-ray FEL, and show that this method can produce fully-coherent X-ray pulses at 100 GW power level. With the radiation beam monochromatized down to the Fourier transform limit, a variety of very different techniques leading to further improvements of the LCLS performance become feasible. In particular, we describe an efficient way for obtaining full polarization control at the LCLS hard X-ray FEL. We also propose to exploit crystals in the Bragg reflection geometry as movable deflectors for the LCLS X-ray transport systems. The hard X-ray beam can be deflected of an angle of order of a radian without perturbations. The monochromatization of the output radiation constitutes the key for reaching such result. Finally, we describe a new optical pump - hard X-ray probe technique which will allow time-resolved studies at the LCLS baseline on the femtosecond time scale. The principle of operation of the proposed scheme is essentially based on the use of the time jitter between pump and probe pulses. This eliminates the need for timing XFELs to high-power conventional lasers with femtosecond accuracy.

Motivation & Objective

  • To enhance the longitudinal coherence of LCLS hard X-ray FEL pulses without major infrastructure changes.
  • To enable high-power, fully coherent X-ray output at the 100 GW level using a compact, low-cost upgrade.
  • To unlock new experimental capabilities such as polarization control, beam deflection, and time-resolved pump-probe spectroscopy.
  • To demonstrate feasibility of the self-seeding scheme in the existing LCLS baseline configuration with minimal modifications.
  • To reduce reliance on ultra-precise timing between pump and probe lasers in time-resolved experiments.

Proposed method

  • A single-crystal monochromator in Bragg transmission geometry is installed within a 4-meter magnetic chicane in the LCLS baseline undulator.
  • The scheme uses a single electron bunch to generate a seed pulse via self-seeding, avoiding time jitter and synchronization issues.
  • The monochromator selects a narrow bandwidth from the SASE FEL radiation, achieving spectral compression to the Fourier transform limit.
  • A subsequent undulator section is tapered (by ~1%) over the last 10 cells to amplify the monochromatic seed to 100 GW peak power.
  • X-ray mirrors are used to spatially separate two SASE pulses from different undulator segments for pump-probe experiments.
  • Crystal deflectors in Bragg reflection geometry are used to steer the monochromatic beam without perturbing the beamline.

Experimental results

Research questions

  • RQ1Can a single-bunch self-seeding scheme with a compact single-crystal monochromator achieve Fourier-limited, fully coherent X-ray pulses at the LCLS baseline?
  • RQ2Can this method enable high-power (100 GW) operation without requiring electron beam bypasses or double-bunch schemes?
  • RQ3How does monochromatization enable full polarization control in the experimental hall with minimal additional cost?
  • RQ4Can monochromatic X-rays facilitate the use of crystal-based deflectors for beam transport and new experimental hall configurations?
  • RQ5Can time-resolved pump-probe experiments be performed without femtosecond synchronization between pump and probe lasers?

Key findings

  • The self-seeding scheme achieves fully coherent X-ray pulses at the Fourier transform limit, significantly improving longitudinal coherence.
  • A peak power of approximately 1.5 GW is achieved in the second undulator section (12 cells), with potential to reach 10 GW using a fresh bunch technique.
  • The method enables a two-order-of-magnitude increase in peak brilliance when applied at higher charge modes (e.g., 0.25 nC).
  • Full polarization control is made feasible by using X-ray phase retarders downstream, enabled by monochromatization with minimal additional cost.
  • Crystal deflectors in Bragg reflection geometry can deflect the X-ray beam by up to a radian without beam degradation, enabled by the narrow bandwidth of the monochromatic pulse.
  • The pump-probe setup with spatially separated SASE pulses achieves clear spectral separation (0.1501 nm and 0.1527 nm), enabling time-resolved studies without precise timing between pulses.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.