[Paper Review] Search for alpha variation in UVES spectra: Analysis of C IV and Si IV doublets towards QSO 1101-264
This study analyzes high-resolution UVES spectra of QSO 1101-264 to search for variations in the fine structure constant 𝛼 using the Alkali Doublet method on C IV and Si IV absorption lines. Despite stringent selection criteria, only Si IV data yielded reliable results, yielding Δ𝛼/𝛼 = (−3.09 ± 8.46) × 10⁻⁵ at z ≈ 1.84, consistent with zero but showing a negative trend aligned with prior findings.
Motivated by previous studies of QSO spectra that reported a variation of the fine structure constant alpha, a search for C IV and Si IV doublets was conducted in the absorption spectrum toward QSO 1101-264, obtained by VLT-UVES during the Science Verification. Seven C IV and two Si IV systems were identified and accurate measurements of wavelengths over the redshift range 1.1862 < z < 1.8377 were performed. After a careful selection of pairs of lines, the "Alkali Doublet" method with a derived analitical expression for the error analysis was applied to compute the alpha variation. The result according in magnitud order with previous doublets measurements, corresponds to one Si IV system: Delta alpha/alpha = (- 3.09 +/- 8.46) x 10^(-5).
Motivation & Objective
- To investigate potential cosmological variation in the fine structure constant 𝛼 using high-resolution quasar absorption spectra.
- To apply the Alkali Doublet method to C IV and Si IV doublets in UVES data from QSO 1101-264, focusing on redshifts 1.1862 < z < 1.8377.
- To improve measurement accuracy by selecting only well-resolved, symmetric, and unblended absorption profiles to minimize systematic errors.
- To assess the reliability of C IV versus Si IV transitions in Δ𝛼/𝛼 determinations, given differences in laboratory wavelength precision.
- To contribute to the growing body of evidence suggesting a possible time variation in fundamental constants, despite current measurements being consistent with zero.
Proposed method
- Acquired high-resolution UVES spectra of QSO 1101-264 during VLT Science Verification, converted from air to vacuum wavelengths.
- Identified seven C IV and two Si IV absorption systems across the redshift range 1.1862 < z < 1.8377 using Voigt profile fitting with a reduced 𝜒² test for goodness of fit.
- Applied the Alkali Doublet (AD) method, where the wavelength separation between the ²S₁/₂ → ²P₃/₂ and ²S₁/₂ → ²P₁/₂ transitions is proportional to 𝛼².
- Used a novel analytical error propagation model based on derivatives of the doublet separation formula, incorporating individual line wavelength uncertainties.
- Applied a relativistic correction term 𝑐𝑟 = (𝛿𝑞₁ − 𝛿𝑞₂)/(𝛿𝑞₁ − 2𝛿𝑞₂), with values 1.1758 for C IV and 0.8914 for Si IV, to account for relativistic effects.
- Selected only the most symmetric, narrow, and unblended components for final analysis, prioritizing Si IV due to better laboratory wavelength accuracy.
Experimental results
Research questions
- RQ1Is there evidence for a cosmological variation in the fine structure constant 𝛼 at redshifts z ≈ 1.8?
- RQ2How do measurements of Δ𝛼/𝛼 from C IV doublets compare to those from Si IV doublets in the same high-resolution spectrum?
- RQ3To what extent do uncertainties in laboratory wavelengths affect the reliability of Δ𝛼/𝛼 determinations?
- RQ4Can the Alkali Doublet method applied to UVES data yield results consistent with previous studies using other instruments?
- RQ5Does the observed trend in Δ𝛼/𝛼, though consistent with zero, support a systematic variation across cosmic time as suggested by earlier work?
Key findings
- Seven C IV and two Si IV absorption systems were identified in the UVES spectrum of QSO 1101-264 over the redshift range 1.1862 < z < 1.8377.
- The C IV doublets yielded larger measurement uncertainties—about one order of magnitude higher—than those from Si IV, despite higher spectral signal-to-noise and resolution.
- The Δ𝛼/𝛼 values from C IV systems showed significant inconsistency with those from Si IV, suggesting potential systematic errors linked to less precise laboratory wavelengths for C IV.
- Only the Si IV system at z ≈ 1.8377 provided a reliable measurement, yielding Δ𝛼/𝛼 = (−3.09 ± 8.46) × 10⁻⁵, consistent with zero but negative.
- The negative sign of the result is consistent with previous findings by Webb et al. (2002), Murphy et al. (2002), and Bahcall et al. (2003), indicating a possible time variation in 𝛼.
- The study concludes that Si IV transitions are more suitable for future Δ𝛼/𝛼 studies due to superior laboratory wavelength precision, and recommends expanding the sample to many more QSOs to reduce error bars.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.