Skip to main content
QUICK REVIEW

[Paper Review] Sensitivity of the DANSS detector to short range neutrino oscillations

M. Danilov|arXiv (Cornell University)|Nov 12, 2013
Neutrino Physics ResearchPhysics and Astronomy2 references14 citations
TL;DR

This paper evaluates the sensitivity of the DANSS detector—installed at the Kalinin Nuclear Power Plant near a 3 GWth reactor—to short-range neutrino oscillations involving sterile neutrinos, using inverse beta decay detection with Gd-doped scintillator strips. With a predicted 10,000 antineutrino events per day and background below 1%, the experiment demonstrates high sensitivity to the reactor anomaly, achieving 95% CL sensitivity to oscillation parameters Δm² ≈ 2 eV² and sin²(2θ₁₄) ≈ 0.2, covering the region favored by the anomaly.

ABSTRACT

DANSS is a highly segmented 1m^3 plastic scintillator detector. It's 2500 scintillator strips have a Gd loaded reflective cover. Light is collected with 3 wave length shifting fibers per strip and read out with 50 PMTs and 2500 SiPMs. The DANSS will be installed under the industrial 3 GW reactor of the Kalinin Nuclear Power Plant at distances varying from 9.7m to 12.2m from the reactor core. Tests of the detector prototype DANSSino demonstrated that in spite of a small size (20x20x100 cm^3) it is quite sensitive to reactor antineutrinos, detecting about 70 Inverse Beta Decay events per day with the signal-to-background ratio of about unity. The prototype tests have demonstrated feasibility to reach the design performance of the DANSS detector. The DANSS experiment will detect about 10 thousand antineutrino events per day with a background below ~1%. Detector will be calibrated every day and its position will be changed frequently to reduce systematic errors. These features will provide a high sensitivity to reactor antineutrino oscillations to sterile neutrinos, suggested recently to explain a so-called "reactor anomaly". Data taking will start already next year.

Motivation & Objective

  • Investigate the potential of the DANSS detector to resolve the reactor antineutrino anomaly via short-range oscillations to sterile neutrinos.
  • Assess the feasibility of detecting sterile neutrino oscillations using a compact, movable, high-precision scintillator detector near a commercial nuclear reactor.
  • Demonstrate that frequent detector repositioning and daily calibration can minimize systematic errors in oscillation measurements.
  • Validate the detector's performance and background levels using the DANSSino prototype at the Kalinin NPP.
  • Provide a quantitative sensitivity estimate for sterile neutrino oscillations based on shape-only spectral analysis at multiple baseline distances.

Proposed method

  • The DANSS detector uses 2500 highly segmented plastic scintillator strips doped with Gd to detect inverse beta decay (IBD) events from reactor antineutrinos.
  • Light from each strip is collected via three wavelength-shifting fibers, read out by 50 PMTs and 2500 SiPMs, enabling precise energy and spatial reconstruction of IBD events.
  • A dual-readout system using orthogonal PMT modules and individual SiPMs per strip improves energy resolution and background rejection.
  • The detector is installed at variable distances (9.7–12.2 m) from the reactor core to measure oscillation effects as a function of baseline.
  • Sensitivity is evaluated using Monte Carlo simulations of positron energy spectra and time correlations between prompt (positron) and delayed (neutron capture) signals.
  • Systematic uncertainties are minimized through daily calibration and frequent repositioning of the detector to average out spatial and environmental effects.

Experimental results

Research questions

  • RQ1Can the DANSS detector achieve sufficient sensitivity to detect short-range neutrino oscillations involving sterile neutrinos, as suggested by the reactor anomaly?
  • RQ2What is the expected sensitivity of the DANSS detector to oscillation parameters Δm² and sin²(2θ₁₄) in the context of the reactor anomaly?
  • RQ3How effective is the DANSS design in suppressing background events, particularly from cosmic muons and (γ,n) coincidences?
  • RQ4To what extent does the detector's ability to vary its baseline distance improve the sensitivity to oscillation parameters?
  • RQ5How reliable are the Monte Carlo simulations in predicting the detector's performance based on prototype (DANSSino) data?

Key findings

  • The DANSSino prototype detected approximately 70 inverse beta decay events per day with a signal-to-background ratio of about unity, confirming the feasibility of the design.
  • The detector is expected to record about 10,000 antineutrino events per day at 11 m from the reactor core, with a background level below 1%.
  • The energy spectrum of positron signals measured by DANSSino shows good agreement with Monte Carlo simulations, validating the detector response model.
  • The ratio of positron energy spectra at 9.7 m and 11 m baselines clearly exhibits an oscillatory pattern for Δm² = 2 eV² and sin²(2θ₁₄) = 0.2, indicating observable oscillations.
  • The 95% confidence level sensitivity contour for one year of running covers the region of parameter space favored by the reactor anomaly, with 95% CL sensitivity to sin²(2θ₁₄) ≈ 0.2 and Δm² ≈ 2 eV².
  • Systematic errors are expected to be minimal due to frequent detector repositioning and daily calibration, enhancing the reliability of the oscillation measurement.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.