Skip to main content
QUICK REVIEW

[Paper Review] Skewness and kurtosis as measures of range mixing in time resolved diode dosimetry

B. Gottschalk|arXiv (Cornell University)|Jul 11, 2014
Radiation Detection and Scintillator TechnologiesPhysics and Astronomy5 references4 citations
TL;DR

This paper proposes using skewness and kurtosis of time-resolved diode signals as statistical indicators to detect range mixing in proton therapy, enabling identification of unreliable diode measurements from scout beam data alone. By comparing measured moments to their natural (no mixing) values, the method computes independent probabilities of deviation, with the product $p_{\text{both}}$ effectively distinguishing diodes affected by range mixing from those reporting trustworthy $\sigma_t$ values.

ABSTRACT

Technical Note describing studies, in 2011, of time resolved diode dosimetry in an anthropomorphic phantom at the Francis H. Burr Proton Therapy Center, Massachusetts General Hospital, Boston, MA. This technique measures the water equivalent path length (WEPL) to a diode dosimeter with sub-millimeter precision, using very little dose. It may allow one to use the proton stopping point (otherwise too uncertain) to cut between tissue to be treated and tissue to be spared, in cases (such as the prostate) where a diode can be placed in a cavity (the rectum) distal to the target. A potential problem is range mixing, where (because of scattering) protons may arrive at a diode with different energy-loss histories. The WEPL reported by such a diode is meaningless and must be ignored. We therefore use an array of diodes, of which some are likely to be at more favorable locations. In addition to the overall analysis of time resolved data, this Note describes in detail how range mixed diodes can be identified by looking at the skewness and kurtosis of the time dependent signal.

Motivation & Objective

  • To develop a method for detecting range mixing in time-resolved diode dosimetry without relying on dose extinction measurements.
  • To identify diodes whose $\sigma_t$ values are compromised by range mixing using only scout beam data.
  • To provide a statistical framework for quantifying the likelihood of observed moment deviations due to range mixing.
  • To validate the method using controlled experiments with known range mixing effects.
  • To enable real-time quality assurance in proton therapy by flagging diodes susceptible to range mixing prior to treatment.

Proposed method

  • Measure time-resolved diode signals during scout beam exposures to extract $\sigma_t$, skewness $s$, and kurtosis $k$.
  • Establish the natural dependence of $s(\sigma_t)$ and $k(\sigma_t)$ on $\sigma_t$ from a clean, uncorrupted run (09MAR11) with no range mixing.
  • Compare measured $s$ and $k$ from clinical runs (15JUN11) to their natural values to compute excess moments.
  • Derive error estimates for excess $s$ and $k$ from the same data to compute $p_{\text{ES}}$ and $p_{\text{EK}}$, the probabilities of observing such deviations due to statistical fluctuations.
  • Combine $p_{\text{ES}}$ and $p_{\text{EK}}$ into $p_{\text{both}} = p_{\text{ES}} \times p_{\text{EK}}$ as a joint indicator of range mixing, leveraging the statistical independence of skewness and kurtosis.
  • Use $p_{\text{both}}$ to flag diodes whose moment deviations are unlikely to be due to chance, indicating range mixing.

Experimental results

Research questions

  • RQ1Can skewness and kurtosis of diode pulse bursts be used to detect range mixing in proton therapy dosimetry?
  • RQ2Is the deviation of skewness and kurtosis from their natural values statistically significant when range mixing occurs?
  • RQ3Can $p_{\text{both}}$ serve as a reliable, independent metric to identify diodes affected by range mixing?
  • RQ4How do the statistical properties of $\sigma_t$, $s$, and $k$ correlate across different beam configurations (open field, aperture+compensator, solid water)?
  • RQ5Can this method detect range mixing without prior knowledge of diode positions in a phantom?

Key findings

  • The 09MAR11 run successfully extracted the natural $s(\sigma_t)$ and $k(\sigma_t)$ functions for DFLR1600 diodes under no range mixing.
  • The 15JUN11 run showed tight correlations between $d(\sigma_t)$ (from scout beam) and $d_{80}$ (from dose extinction), consistent with prior findings by S. Tang.
  • Excess skewness and kurtosis were observed in diodes exposed to range mixing, with $p_{\text{ES}}$ and $p_{\text{EK}}$ computed from data-derived error estimates.
  • The product $p_{\text{both}} = p_{\text{ES}} \times p_{\text{EK}}$ effectively discriminated between diodes with normal dose extinction and those affected by range mixing.
  • The method enables identification of range-mixed diodes from scout beam data alone, without knowing their positions in the phantom.
  • Discrepancies of ~1 mm between $d(\sigma_t)$ and $d_{80}$ remain unresolved but are expected to be reduced with improved measurements.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.