[Paper Review] Status and prospects of the NEXT experiment for neutrinoless double beta decay searches
This paper presents the status and future prospects of the NEXT experiment, a high-pressure xenon time projection chamber (HPXe-EL) with electroluminescent readout, designed to search for neutrinoless double beta decay in $^{136}$Xe. The NEXT-White demonstrator at Canfranc Underground Laboratory has validated the technology’s energy resolution and topological reconstruction, while NEXT-100 (100 kg Xe) is set to begin operations in 2020, aiming for background-free operation, with future phases like NEXT-HD and NEXT-BOLD targeting ton-scale, ultra-low-background detectors using improved energy resolution and barium ion tagging.
NEXT (Neutrino Experiment with a Xenon TPC) is an experimental program whose goals are to discover neutrinoless double beta decay using $^{136}$Xe in high pressure xenon TPCs with electroluminescent readout. In this paper, results from the NEXT-White detector, which is currently taking data at Laboratorio Subterráneo de Canfranc (LSC) will be reported. The prospects for the NEXT-100 apparatus, scheduled to start operations in 2020, as well as the plans to extend the technology to large and ultra-low background detectors needed to fully explore the inverse hierarchy of neutrino masses, will also be briefly discussed.
Motivation & Objective
- To develop and validate high-pressure xenon gas time projection chambers with electroluminescent readout for background-free neutrinoless double beta decay searches.
- To demonstrate the feasibility of using 5 kg of enriched $^{136}$Xe in the NEXT-White detector at the Canfranc Underground Laboratory.
- To achieve background-free operation at the 100 kg scale with the NEXT-100 experiment.
- To explore next-generation approaches—NEXT-HD and NEXT-BOLD—capable of reaching ton-scale masses with ultra-low backgrounds.
- To enable the exploration of the inverse neutrino mass hierarchy through enhanced energy resolution and barium ion tagging.
Proposed method
- Utilizes high-pressure xenon gas (15 bar) in a time projection chamber (TPC) to detect ionization and scintillation signals from double beta decay.
- Employs electroluminescence (EL) for amplification of ionization electrons at the anode, producing secondary scintillation (S2) light.
- Uses two photodetector planes: PMTs in the energy plane for energy measurement and S1 timing, and SiPMs in the tracking plane for transverse position reconstruction.
- Applies vacuum ultraviolet (VUV) photons (~172 nm) from primary scintillation (S1) and converts them to visible light via TPB coating on the anode.
- Implements radiopure materials (e.g., 316Ti stainless steel, HDPE, copper) and a lead shield to minimize background radiation.
- Explores two future paths: NEXT-HD for enhanced energy resolution and reduced background budget, and NEXT-BOLD for delayed coincidence detection of single Ba++ ions via surface-bound fluorescent indicators.
Experimental results
Research questions
- RQ1Can a high-pressure xenon TPC with electroluminescent readout achieve the required energy resolution and background suppression for neutrinoless double beta decay searches?
- RQ2Can the NEXT-White demonstrator successfully validate the HPXe-EL technology in a low-background underground environment?
- RQ3Can NEXT-100 achieve background-free operation at the 100 kg scale with 15 bar xenon and optimized radiopurity?
- RQ4Can barium ion tagging via single-molecule fluorescence imaging (SMFI) enable truly background-free detection in future ton-scale detectors?
- RQ5What sensitivity and exposure are required for NEXT to probe the inverse neutrino mass hierarchy?
Key findings
- The NEXT-White detector, operating with 5 kg of enriched $^{136}$Xe at the Canfranc Underground Laboratory, has successfully demonstrated the core HPXe-EL TPC technology, including energy resolution and topological reconstruction.
- NEXT-100, scheduled to begin operations in 2020, is expected to achieve background-free operation at the 100 kg scale using 15 bar xenon and optimized radiopurity.
- The NEXT-HD path is projected to achieve a half-life sensitivity of $2 \times 10^{27}$ years with a 6 t·yr exposure, targeting the inverse neutrino mass hierarchy.
- The NEXT-BOLD approach, using single Ba++ ion tagging via SMFI, could achieve a sensitivity of $8 \times 10^{27}$ years after a 10 t·yr exposure, enabling truly background-free operation.
- Proof-of-concept experiments have demonstrated single Ba++ ion detection in dry medium using SMFI, though challenges remain in developing dry-compatible, high-contrast fluorescent indicators.
- New fluorescent indicators capable of fluorescing in dry environments have been synthesized, supporting the feasibility of future Ba++ tagging in HPXe-EL detectors.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.