TL;DR

This paper proposes a fluorescent bicolor sensor based on the FBI molecule to enable background-free detection of neutrinoless double beta decay in xenon gas time projection chambers by identifying single Ba²⁺ ions via laser-induced fluorescence. The sensor exhibits a 17±4 fold increase in fluorescence upon Ba²⁺ chelation, shifting emission from green to blue, with a detection sensitivity of 6.2×10² GM per Ba²⁺ ion, enabling unambiguous identification of the decay's daughter nucleus.

ABSTRACT

Searching for neutrinoless double beta decays ($β\beta0ν$) is the only practical way to establish if the neutrinos are their own antiparticles. Due to the smallness of neutrino masses, the lifetime of $β\beta0ν$ is expected to be at least ten orders of magnitude smaller than the noise associated with the natural radioactive chains. A positive identification of $β\beta0ν$ decays requires, ultimately, finding a signal that cannot be mimicked by radioactive backgrounds. This signal could be the observation of the daughter atom in the decay, since no known background processes induce a Z+2 transformation. In particular, the $β\beta0ν$ decay of Xe-136 could be established by detecting the doubly ionised daughter atom, Ba$^{2+}$. Such a detection could be achieved via a sensor made of a monolayer of molecular indicators. The Ba$^{2+}$ would be captured by one of the molecules in the sensor, and the presence of the single chelated indicator would be subsequently revealed by a strong fluorescent response from repeated interrogation with a laser system. Here we describe a fluorescent bicolor indicator that binds strongly to Ba$^{2+}$ and shines very brightly, shifting its emission colour from green to blue when chelated in dry medium, thus allowing the unambiguous identification of single barium atoms in the sensor, and permitting a positive identification of the $β\beta0ν$ decay of Xe-136 in a gas chamber, that could led to a background-free experiment.

Motivation & Objective

  • To develop a background-free experimental approach for detecting neutrinoless double beta decay (ββ0ν) by identifying the Z+2 daughter nucleus, Ba²⁺.
  • To overcome the dominant challenge of radioactive background in existing experiments by using a unique, unambiguous signature: the formation of Ba²⁺.
  • To design a fluorescent molecular indicator that selectively binds Ba²⁺ and produces a distinct, resolvable optical signal in dry, gas-phase conditions.
  • To achieve single-atom sensitivity for Ba²⁺ detection using a laser-scanning system with a fluorescent bicolor sensor.

Proposed method

  • Design and synthesize a fluorescent indicator, FBI (7ca), capable of chelating Ba²⁺ with high selectivity and inducing a large fluorescence color shift from green to blue upon binding.
  • Use two-photon absorption (TPA) microscopy with an 800 nm infrared laser to excite the sensor, enabling deep penetration and high spatial resolution in solid-gas interfaces.
  • Measure fluorescence response in solution and solid phase to quantify signal enhancement upon Ba²⁺ binding, using emission spectra and intensity ratios as key metrics.
  • Apply the fluorescence enhancement ratio R_fluo/fbi = 17±4 to calibrate detection sensitivity, with the signal normalized to photomultiplier tube (PMT) counts.
  • Use the formula δ_FBI·Ba²⁺ = 6.2±1.2×10² GM to quantify the sensor’s sensitivity per Ba²⁺ ion, enabling single-atom detection.
  • Test selectivity against other alkaline earth ions (Mg²⁺, Ca²⁺, Sr²⁺) to confirm that only Ba²⁺ and Sr²⁺ induce the fluorescence shift, validating specificity.

Experimental results

Research questions

  • RQ1Can a fluorescent bicolor sensor be engineered to detect single Ba²⁺ ions with high selectivity and sensitivity in a dry, gas-phase environment?
  • RQ2Does the fluorescence emission of the FBI molecule shift from green to blue upon chelation with Ba²⁺, enabling unambiguous identification of the ion?
  • RQ3What is the fluorescence enhancement ratio (R_fluo/fbi) of the FBI sensor upon Ba²⁺ binding, and can it support single-atom detection in a background-free experiment?
  • RQ4How selective is the FBI sensor for Ba²⁺ compared to other alkaline earth ions such as Mg²⁺, Ca²⁺, and Sr²⁺?
  • RQ5Can the sensor’s response be quantified in terms of signal output per Ba²⁺ ion, enabling calibration for use in a large-scale neutrinoless double beta decay experiment?

Key findings

  • The FBI sensor exhibits a 17±4 fold increase in fluorescence intensity upon chelation with Ba²⁺, measured via the ratio R_fluo/fbi, confirming strong signal enhancement.
  • The emission color of the FBI sensor shifts from green to blue upon Ba²⁺ binding, enabling unambiguous optical identification of the chelated state.
  • The sensor achieves a detection sensitivity of 6.2×10² GM per Ba²⁺ ion, quantified as δ_FBI·Ba²⁺, which supports single-atom detection capability.
  • The FBI sensor selectively binds Ba²⁺ and Sr²⁺ due to similar ionic radii (2.22 Å and 2.15 Å), but does not bind Ca²⁺ (1.97 Å) or Mg²⁺ (1.60 Å), demonstrating high selectivity.
  • Two-photon absorption (TPA) microscopy using an 800 nm laser enables efficient excitation of the sensor with a diffraction-limited spot size (~1 μm³), suitable for single-molecule detection.
  • The fluorescence response is stable and resolvable in dry media, overcoming the limitations of traditional aqueous indicators, making it suitable for solid-gas interfaces in high-pressure xenon TPCs.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.