[Paper Review] Strategies for triple-donor devices fabricated by ion implantation
This paper proposes ion implantation as a viable fabrication strategy for triple-donor devices in silicon to demonstrate the Coherent Tunneling Adiabatic Passage (CTAP) protocol for quantum computing. Using SRIM simulations and hydrogenic approximations for tunnel matrix elements, the authors predict a theoretical device yield of ~80% for 14 keV phosphorus implants at 20 nm spacing, indicating strong feasibility for proof-of-concept CTAP experiments despite atomic-scale positioning challenges.
Triple donor devices have the potential to exhibit adiabatic tunneling via the CTAP (Coherent Tunneling Adiabatic Passage) protocol which is a candidate transport mechanism for scalable quantum computing. We examine theoretically the statistics of dopant placement using counted ion implantation by employing an analytical treatment of CTAP transport properties under hydrogenic assumptions. We determine theoretical device yields for proof of concept devices for different implant energies. In particular, we determine a significant theoretical device yield (~80%) for 14keV phosphorus in silicon with nominal 20nm spacing.
Motivation & Objective
- To evaluate ion implantation as a practical fabrication method for proof-of-concept triple-donor devices in silicon suitable for the CTAP protocol.
- To estimate theoretical device yields for CTAP transport under realistic dopant placement statistics from ion implantation.
- To guide experimental design by analyzing implant energy and aperture parameters that maximize yield and maintain adiabaticity.
- To assess the feasibility of achieving high-fidelity CTAP transport within decoherence limits using analytical models and SRIM simulations.
Proposed method
- Employed SRIM simulations to model the spatial distribution of 100,000 14 keV and 7 keV phosphorus ions implanted through 10 nm diameter apertures spaced 20 nm apart.
- Applied hydrogenic approximations to calculate tunnel matrix elements and derive analytical expressions for the required CTAP transfer time under adiabaticity.
- Used the adiabaticity criterion with a threshold of ๐ = 0.01 to determine the maximum allowable transfer time for high-fidelity transport.
- Convolved SRIM-determined dopant straggles with 10 nm apertures to simulate realistic device geometry and assess statistical yield.
- Generated cumulative distribution functions of CTAP times to estimate the fraction of implant configurations meeting the 1 ns decoherence-limited speed requirement.
- Evaluated two implant strategies: 14 keV P through 5 nm SiOโ and 7 keV P through 1.2 nm SiOโ, representing practical fabrication limits.
Experimental results
Research questions
- RQ1What is the theoretical yield of functional triple-donor devices using ion implantation for CTAP transport, given dopant placement statistics?
- RQ2How do different implant energies (14 keV vs. 7 keV) affect the probability of achieving adiabatic CTAP transport within decoherence limits?
- RQ3To what extent do dopant straggles and non-uniform placements compromise the controllability of tunnel matrix elements in CTAP devices?
- RQ4Can analytical models based on hydrogenic approximations reliably predict CTAP transfer times for ion-implanted donor arrays?
- RQ5What are the practical limits of ion implantation for realizing scalable CTAP-based quantum computing architectures?
Key findings
- The theoretical device yield for 14 keV phosphorus implants at 20 nm spacing is estimated at approximately 80%, assuming ideal gate control and hydrogenic approximations.
- For the lower-energy 7 keV implant strategy, the theoretical yield increases to approximately 90%, due to reduced dopant straggles and better control over donor positions.
- The cumulative distribution of CTAP transfer times shows that 80% of 14 keV implant configurations satisfy the 1 ns threshold, which is an order of magnitude faster than the estimated 10 ns decoherence time.
- Over 95% of the simulated donor triples have tunnel matrix elements ๐ฅ < 1, indicating that most configurations are potentially controllable, though some may still be too strongly coupled for effective gate control.
- The results suggest that ion implantation is a feasible route for proof-of-concept CTAP devices, though scaling to longer chains will require more precise methods like hydrogen resist lithography.
- Limitations of the model include the use of hydrogenic approximations and the omission of oxide breakdown effects, which may reduce actual yields below theoretical estimates.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.