[Paper Review] Thermo-optic coefficient measurement of liquids using silicon photonic microring resonators
This paper presents a silicon photonic microring resonator platform for on-chip measurement of the thermo-optic coefficient (TOC) of liquids, leveraging temperature-dependent resonant wavelength shifts and integrated on-chip temperature sensing. The method achieves a TOC measurement of −1.12×10⁻⁴/°C for deionized water with an uncertainty of ±8.26×10⁻⁶/°C, enabling real-time thermal noise compensation in refractometric sensing.
On-chip measurement of thermo-optic coefficient (TOC) of samples along with on-chip temperature measurements can be used to compensate for thermal fluctuation induced noise in refractometry using integrated photonic sensors. In this article we demonstrate a device design and describe the method to extract TOCs of liquid samples using resonant wavelength shifts of a silicon microring resonator. The TOCs of three standard fluids; De-ionized water, Ethanol and Isopropanol, were determined using our sensor and show a good agreement with values reported in literature. A mechanism for tracking of on-chip temperature variations is also included for ensuring accuracy of TOC measurements. Potential applications of the demonstrated on-chip TOC sensor include improvements in accuracy of refractive index measurements and multiparametric analysis of biochemical analytes.
Motivation & Objective
- To develop a compact, on-chip method for measuring the thermo-optic coefficient (TOC) of liquid analytes using silicon photonic microring resonators.
- To address thermal noise in on-chip refractometry by enabling real-time correction through accurate TOC and temperature measurements.
- To minimize errors from fabrication mismatch and spatial temperature gradients by directly measuring the TOC of the analyte rather than relying on reference rings.
- To enable multiparametric analysis by providing independent measurement of TOC, which correlates with chemical composition and thermal expansion.
Proposed method
- Utilizes temperature-induced shifts in the resonant wavelength of a silicon microring resonator to extract the thermo-optic coefficient of the surrounding liquid.
- Employs field confinement theory in high-contrast waveguides to model the effective index change as a function of temperature-dependent refractive index changes in core, cladding, and buried oxide.
- Integrates a metal ring structure on the chip to monitor local temperature variations via electrical resistance, enabling real-time thermal tracking.
- Applies a calibration method using known temperature ramps and measures the slope of resonant wavelength shift versus temperature to compute TOC.
- Uses modal simulations and SEM measurements to quantify uncertainties from waveguide width variations and slope measurement noise.
- Derives uncertainty contributions using error propagation, combining slope uncertainty and waveguide width variation to estimate total TOC uncertainty.
Experimental results
Research questions
- RQ1Can the thermo-optic coefficient of a liquid be accurately measured on-chip using silicon photonic microring resonators?
- RQ2How can on-chip temperature variations be tracked in real time to improve the accuracy of TOC measurements?
- RQ3What are the dominant sources of uncertainty in TOC estimation using this method, and how can they be quantified?
- RQ4Can this method enable improved refractive index sensing by compensating for thermal fluctuations?
- RQ5To what extent does the measured TOC of standard liquids like water, ethanol, and isopropanol agree with literature values?
Key findings
- The thermo-optic coefficient of deionized water was measured as −1.12×10⁻⁴/°C with a total uncertainty of ±8.26×10⁻⁶/°C.
- The uncertainty budget was dominated by slope measurement uncertainty (6.42×10⁻⁶/°C) and waveguide width variation (5.19×10⁻⁶/°C), with combined effect computed via root-sum-square.
- The detection limit for TOC measurement was determined to be 2.47×10⁻⁵/°C, defined as three times the standard uncertainty.
- Measured TOC values for ethanol and isopropanol were consistent with literature, validating the method’s accuracy.
- The on-chip temperature sensing via metal ring resistance provided real-time tracking of local thermal variations, reducing error from spatial temperature gradients.
- The method enables direct, on-chip TOC measurement without reliance on reference rings, mitigating fabrication-induced mismatches and spatial thermal drifts.