This paper proposes a process-controlled medical robotic system (PCMRS) using hierarchical Finite State Machines (hFSM) to formalize clinical workflows into deterministic, machine-executable procedures, enabling automated, safe, and accurate robotic interventions. The system achieves sub-millimeter precision in two applications: transcranial magnetic stimulation (0.25 mm translational error) and femoroplasty (0.5979 mm translational error), demonstrating reliable state transitions and real-time control in dynamic surgical environments.
Medical errors, defined as unintended acts either of omission or commission that cause the failure of medical actions, are the third leading cause of death in the United States. The application of autonomy and robotics can alleviate some causes of medical errors by improving accuracy and providing means to follow planned procedures. However, for the robotic applications to improve safety, they must maintain constant operating conditions in the presence of disturbances, and provide reliable measurements, evaluation, and control for each state of the procedure. This article addresses the need for process control in medical robotic systems, and proposes a standardized design cycle toward its automation. Monitoring and controlling the changing conditions in a medical or surgical environment necessitates a clear definition of workflows and their procedural dependencies. We propose integrating process control into medical robotic workflows to identify change in states of the system and environment, possible operations, and transitions to new states. Therefore, the system translates clinician experiences and procedure workflows into machine-interpretable languages. The design cycle using hFSM formulation can be a deterministic process, which opens up possibilities for higher-level automation in medical robotics. Shown in our work, with a standardized design cycle and software paradigm, we pave the way toward controlled workflows that can be automatically generated. Additionally, a modular design for a robotic system architecture that integrates hFSM can provide easy software and hardware integration. This article discusses the system design, software implementation, and example application to Robot-Assisted Transcranial Magnetic Stimulation and robot-assisted femoroplasty. We provide assessments using performance in terms of robotic tool placement and response to failure injections.
Motivation & Objective
- To address the high rate of medical errors caused by human factors such as poor judgment and communication breakdowns in surgical procedures.
- To develop a standardized, deterministic design cycle for medical robotic systems that enables higher-level automation through formalized procedural control.
- To integrate process control into medical robotics by translating clinician expertise and procedural workflows into machine-interpretable state transitions using hierarchical Finite State Machines (hFSM).
- To enable reliable, real-time robotic control in dynamic environments through modular software and hardware integration with robust communication protocols.
- To validate the system in two clinical applications: robot-assisted transcranial magnetic stimulation (RATMS) and robot-assisted femoroplasty, demonstrating high accuracy and procedural consistency.
Proposed method
- The system employs a hierarchical Finite State Machine (hFSM) framework to model procedural workflows, where each state represents a procedural phase and transitions are governed by predefined conditions.
- The hFSM design translates clinician experience and procedural dependencies into a formal, deterministic state transition model, enabling automation of complex, multi-step interventions.
- A modular software architecture based on ROS (Robot Operating System) and UDP-based communication ensures real-time data exchange between perception, planning, actuation, and visualization modules.
- The system integrates 3D Slicer and Unity for real-time 3D visualization and teleoperation, with frame rates stable at 60 Hz for consistent user feedback.
- The design supports both UDP (low-latency) and optional TCP (reliable) communication, enabling flexible deployment across distributed computing environments.
- The system is validated through two clinical applications: RATMS and robot-assisted femoroplasty, with quantitative error assessment of robotic tool placement.
Experimental results
Research questions
- RQ1How can medical robotic systems achieve higher-level automation by formalizing clinical workflows into deterministic, machine-executable procedures?
- RQ2To what extent can hierarchical Finite State Machines (hFSM) model complex, dynamic surgical workflows with procedural dependencies and state transitions?
- RQ3Can a standardized, modular robotic system architecture ensure reliable, real-time control and accurate tool placement in diverse medical interventions?
- RQ4What level of accuracy and consistency can be achieved in robotic tool placement when using process control via hFSM in clinical applications like RATMS and femoroplasty?
- RQ5How does the integration of perception, planning, actuation, and visualization through a unified software paradigm improve procedural safety and reproducibility?
Key findings
- The PCMRS system achieved an average translational error of 0.2504 mm and rotational error of 0.1034 degrees in robot-assisted transcranial magnetic stimulation (RATMS), demonstrating high precision in non-invasive brain stimulation.
- In robot-assisted femoroplasty using a femur phantom, the system achieved an average translational error of 0.5979 mm and rotational error of 0.1500 degrees, confirming accuracy in orthopedic interventions.
- The system executed procedures strictly according to hFSM-defined state transitions, preventing invalid operations and ensuring procedural integrity.
- Real-time visualization in 3D Slicer and Unity maintained a stable frame rate of at least 60 Hz, enabling reliable teleoperation and user feedback.
- The use of UDP-based communication ensured low-latency data transfer, critical for high-frequency sensor streaming and real-time control in dynamic environments.
- The modular, ROS-based software architecture enabled seamless integration of perception, planning, actuation, and visualization components, supporting extensibility and reuse across different medical applications.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.