[Paper Review] Trapped magnetic flux in hydrogen-rich high-temperature superconductors
This paper introduces a novel trapped flux magnetic measurement technique to detect superconductivity in hydrogen-rich hydrides under high pressure, overcoming limitations of conventional electrical transport and magnetic susceptibility methods. The method enables precise determination of Tc ~195 K, critical fields, London penetration depth (~37 nm), and critical current density in H3S at ~155 GPa, with enhanced sensitivity and reduced background noise compared to standard approaches.
Recent discoveries of superconductivity in hydrogen-rich compounds stabilized by high pressures have shown that a critical temperature of superconductivity Tc can reach near room temperature values. The current studies focus on the search for new superconductors with higher Tcs to understand the ultimate limit of conventional superconductivity, and high-Tc superconductors at lower pressures. However, high pressure conditions put serious limitations on experimental studies. Electrical transport measurements have long been the primary experimental technique for reliable detection of superconductivity at high pressures, whereas magnetic susceptibility measurements continue to be a challenge. Here, we dramatically changed the protocol of magnetic measurements to probe the trapped magnetic flux. We tested this technique on samples of H3S and LaH10 and propose it for a routine examination of superconductivity at high pressures. Using the temperature- and magnetic field dependences of the trapped flux we estimated Tc ~195 K, a lower critical field ~0.36 T, an irreversibility field ~1.7 T, a full penetration field ~8.8 T, the London penetration depth ~37 nm, and critical current densities jc(T) in H3S at ~155 GPa in a wide temperature range. The trapped flux method is found to be sensitive to a particular phase in a mixture of superconducting phases: concomitant phases of sulfur and hydrogen-depleted LaHx were detected. In contrast to the Meissner state occurring at low external magnetic fields, a magnetic response from the trapped flux at zero applied magnetic field is in tens times stronger and is not contaminated by the magnetic background of a bulky diamond anvil cell. This technique can be a powerful tool for the screening of new superconducting materials, the study of multiphase, contaminated samples, or samples with a low superconducting fraction at ambient pressure too.
Motivation & Objective
- To address the challenge of detecting superconductivity in high-pressure hydrogen-rich hydrides using conventional magnetic susceptibility measurements, which are limited by experimental complexity and background interference.
- To develop a robust, routine method for identifying superconducting phases in complex, multiphase, or low-fraction samples under high pressure.
- To enable accurate determination of key superconducting parameters such as Tc, critical fields, penetration depth, and critical current density in hydrogen-rich superconductors.
- To demonstrate the method's sensitivity to individual superconducting phases even in mixtures, such as sulfur and hydrogen-depleted LaHx in LaH10.
Proposed method
- The technique involves applying a magnetic field to align flux lines in a superconductor, then removing the field to trap magnetic flux, which is subsequently probed at zero external field.
- Magnetic response from the trapped flux is measured using a SQUID-based magnetometer, providing a signal that is tens of times stronger than the Meissner effect at low fields.
- The method is applied to high-pressure samples of H3S and LaH10 using a cubic anvil press with a diamond anvil cell, enabling in-situ measurements at high pressures.
- Temperature- and field-dependent trapped flux measurements are used to extract superconducting parameters via fitting to Ginzburg-Landau and London theories.
- The technique is validated by detecting distinct magnetic responses from different superconducting phases in multiphase samples, such as H3S and LaHx.
Experimental results
Research questions
- RQ1Can trapped magnetic flux measurements provide a more sensitive and background-free alternative to conventional magnetic susceptibility for detecting superconductivity in high-pressure hydrides?
- RQ2To what extent can the trapped flux method resolve individual superconducting phases in a mixture of phases, such as in hydrogen-depleted LaHx and H3S?
- RQ3What are the quantitative values of key superconducting parameters—Tc, lower critical field, irreversibility field, penetration depth, and critical current density—in H3S under high pressure?
- RQ4How does the trapped flux signal compare in magnitude and reliability to the Meissner effect in standard magnetic measurements?
Key findings
- The critical temperature Tc of H3S was determined to be approximately 195 K under ~155 GPa pressure, consistent with high-temperature superconductivity.
- The lower critical field Hc1 was estimated at ~0.36 T, and the irreversibility field Hinvar was found to be ~1.7 T, indicating strong vortex pinning.
- The full penetration field Hc2 was measured at ~8.8 T, consistent with a type-II superconductor with a London penetration depth of ~37 nm.
- The critical current density jc(T) in H3S was estimated to be on the order of ~10^6 A/cm² at 10 K, indicating high current-carrying capacity.
- The trapped flux method detected concomitant superconducting phases such as sulfur and hydrogen-depleted LaHx, demonstrating phase-specific sensitivity in multiphase samples.
- The trapped flux signal was tens of times stronger than the Meissner effect and exhibited minimal background from the diamond anvil cell, enhancing measurement sensitivity.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.