TL;DR

This study presents a rigorous method to unambiguously determine spin dephasing times (T₂*) in ZnO using time-resolved magneto-optical pump-probe experiments and resonant spin amplification (RSA), revealing that misleading T₂* values arise from overlapping spin components and pump-pulse crosstalk. The authors demonstrate that conventional analyses can produce erroneous temperature-dependent T₂* trends due to misinterpretation of multiple spin species with distinct dephasing times, and that RSA results are compromised at high laser powers due to spin replacement by consecutive pulses.

ABSTRACT

Time-resolved magneto-optics is a well-established optical pump probe technique to generate and to probe spin coherence in semiconductors. By this method, spin dephasing times T_2^* can easily be determined if their values are comparable to the available pump-probe-delays. If T_2^* exceeds the laser repetition time, however, resonant spin amplification (RSA) can equally be used to extract T_2^*. We demonstrate that in ZnO these techniques have several tripping hazards resulting in deceptive values for T_2^* and show how to avoid them. We show that the temperature dependence of the amplitude ratio of two separate spin species can easily be misinterpreted as a strongly temperature dependent T_2^* of a single spin ensemble, while the two spin species have T_2^* values which are nearly independent of temperature. Additionally, consecutive pump pulses can significantly diminish the spin polarization, which remains from previous pump pulses. While this barely affects T_2^* values extracted from delay line scans, it results in seemingly shorter T_2^* values in RSA.

Motivation & Objective

  • To resolve persistent ambiguities in measuring spin dephasing times (T₂*) in ZnO using standard pump-probe and RSA techniques.
  • To identify and correct systematic errors in T₂* extraction that arise from overlapping spin components with different dephasing times.
  • To demonstrate that apparent temperature dependence of T₂* in ZnO is an artifact of misinterpreting amplitude ratios between two distinct spin species.
  • To show that RSA yields falsely shortened T₂* values at high laser powers due to spin replacement by consecutive pump pulses.
  • To establish a reliable protocol for unambiguous T₂* determination using extended pump-probe delay scans and independent laser control.

Proposed method

  • Employed two independently tunable Ti:Sapphire lasers with sub-1 ps timing jitter to enable electronic delay control over the full 12.5 ns laser repetition period.
  • Used circularly polarized pump pulses at 369.4 nm (3.3567 eV) to selectively excite donor-bound excitons on indium and aluminum sites via DIn⁰XA and DAl⁰XB transitions.
  • Performed time-resolved Faraday ellipticity measurements to detect spin precession and extract T₂* from exponential decay of the signal in pump-probe delay scans.
  • Applied resonant spin amplification (RSA) by sweeping the magnetic field at fixed delays to extract T₂* from resonance linewidths.
  • Conducted pump-pump-probe experiments to isolate and quantify spin replacement effects from consecutive pump pulses.
  • Used a two-step demodulation technique to disentangle contributions from multiple spin components with distinct T₂* values.

Experimental results

Research questions

  • RQ1Why do conventional pump-probe delay scans in ZnO yield misleadingly temperature-dependent T₂* values despite the actual T₂* being nearly temperature-independent?
  • RQ2How does the presence of multiple spin species with different dephasing times affect the interpretation of time-resolved magneto-optical signals?
  • RQ3To what extent does pump-pulse crosstalk in RSA experiments distort the measured T₂* values in ZnO?
  • RQ4Can the unambiguous determination of T₂* be achieved in systems with overlapping spin components and long dephasing times?
  • RQ5What experimental conditions are necessary to avoid artifacts in RSA-based T₂* measurements due to non-linear spin polarization accumulation?

Key findings

  • The apparent temperature dependence of T₂* in ZnO is an artifact of misinterpreting the amplitude ratio between two spin components (In and Al donors), each with nearly temperature-independent T₂*.
  • Spin dephasing times for donor electrons on indium and aluminum sites in ZnO are approximately 1.2 ns and 0.8 ns, respectively, and show weak temperature dependence.
  • Standard pump-probe delay scans fail to resolve multiple spin components when T₂* exceeds the available delay range, leading to erroneous extraction of a single effective T₂*.
  • Resonant spin amplification (RSA) yields falsely shortened T₂* values at high laser powers due to spin replacement by subsequent pump pulses, which diminish residual spin polarization.
  • The use of two independently tunable lasers enables full delay scanning up to 12.5 ns and allows unambiguous identification of three distinct spin components with different T₂* values.
  • Even without dual lasers, reliable T₂* determination can be achieved by analyzing data at negative delays (Δt < 0) or using path-length delays to extend the effective delay range.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint