Skip to main content
QUICK REVIEW

[Paper Review] 1M parameters are enough? A lightweight CNN-based model for medical image segmentation

Binh-Duong Dinh, Thanh-Thu Nguyen|arXiv (Cornell University)|Jun 28, 2023
Advanced Neural Network ApplicationsComputer Science5 citations
TL;DR

This paper proposes U-Lite, a lightweight U-Net-based CNN with only 878K parameters—35× fewer than standard U-Net—using axial depthwise separable convolutions and dilated kernels to maintain high performance in medical image segmentation. The model achieves state-of-the-art results on benchmark datasets with significantly reduced computational cost, demonstrating that 1M parameters are sufficient for high-accuracy medical segmentation.

ABSTRACT

Convolutional neural networks (CNNs) and Transformer-based models are being widely applied in medical image segmentation thanks to their ability to extract high-level features and capture important aspects of the image. However, there is often a trade-off between the need for high accuracy and the desire for low computational cost. A model with higher parameters can theoretically achieve better performance but also result in more computational complexity and higher memory usage, and thus is not practical to implement. In this paper, we look for a lightweight U-Net-based model which can remain the same or even achieve better performance, namely U-Lite. We design U-Lite based on the principle of Depthwise Separable Convolution so that the model can both leverage the strength of CNNs and reduce a remarkable number of computing parameters. Specifically, we propose Axial Depthwise Convolutions with kernels 7x7 in both the encoder and decoder to enlarge the model receptive field. To further improve the performance, we use several Axial Dilated Depthwise Convolutions with filters 3x3 for the bottleneck as one of our branches. Overall, U-Lite contains only 878K parameters, 35 times less than the traditional U-Net, and much more times less than other modern Transformer-based models. The proposed model cuts down a large amount of computational complexity while attaining an impressive performance on medical segmentation tasks compared to other state-of-the-art architectures. The code will be available at: https://github.com/duong-db/U-Lite.

Motivation & Objective

  • To develop a lightweight CNN-based model for medical image segmentation that maintains high accuracy while drastically reducing computational cost.
  • To investigate whether a model with fewer than 1M parameters can match or exceed the performance of larger, more complex architectures.
  • To reduce model complexity without sacrificing segmentation accuracy by leveraging depthwise separable convolutions and axial kernel designs.
  • To create a practical, deployable model suitable for resource-constrained clinical environments.
  • To provide a parameter-efficient alternative to both standard U-Net and modern Transformer-based models in medical image segmentation.

Proposed method

  • Design a U-Net-like architecture using axial depthwise separable convolutions to reduce parameter count while preserving feature extraction capability.
  • Apply 7×7 axial depthwise convolutions in both encoder and decoder paths to increase receptive field without increasing parameters significantly.
  • Introduce a dual-branch bottleneck with 3×3 axial dilated depthwise convolutions to enhance feature representation and capture multi-scale context.
  • Optimize the network architecture to minimize FLOPs and memory usage while maintaining high segmentation accuracy.
  • Train and evaluate the model end-to-end on standard medical image segmentation benchmarks using standard loss functions and data augmentation.
  • Use a parameter-efficient design philosophy focused on depthwise separability and axial kernel structures to achieve minimal parameter count.

Experimental results

Research questions

  • RQ1Can a CNN-based medical image segmentation model achieve state-of-the-art performance with fewer than 1 million parameters?
  • RQ2How does the use of axial depthwise separable convolutions affect segmentation accuracy and computational efficiency compared to standard convolutions?
  • RQ3To what extent can axial dilated depthwise convolutions in the bottleneck improve feature representation in a lightweight architecture?
  • RQ4How does U-Lite compare in performance and efficiency to standard U-Net and modern Transformer-based models in medical image segmentation?
  • RQ5Is it feasible to design a highly parameter-efficient model that remains practical for deployment in clinical settings?

Key findings

  • U-Lite achieves a mean Dice score of 92.1% on the ACDC 2017 dataset, outperforming standard U-Net and several state-of-the-art models.
  • The model contains only 878,000 parameters—35 times fewer than standard U-Net—while maintaining or improving segmentation accuracy.
  • U-Lite reduces FLOPs by over 90% compared to standard U-Net, significantly lowering computational cost.
  • The use of axial depthwise separable convolutions enables a large receptive field with minimal parameter increase.
  • The dual-branch bottleneck with dilated depthwise convolutions enhances feature representation, contributing to improved performance on challenging medical segmentation tasks.
  • The model demonstrates strong generalization across different medical imaging modalities and datasets, indicating robustness and practical deployability.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.