[Paper Review] 3He Lung Imaging in an Open Access, Very-Low-Field Human MRI System
This study demonstrates in vivo 3He lung imaging in a low-cost, open-access, very-low-field (less than 5 mT) MRI system using a simple electromagnet with open geometry. The system enables functional lung imaging in multiple subject orientations—such as supine and upright—overcoming gravity-related limitations of conventional high-field MRI, with 4 mm in-plane resolution achieved in two-dimensional images from a single volunteer.
The human lung and its functions are extremely sensitive to gravity, however the conventional high-field magnets used for most laser-polarized 3He MRI of the human lung restrict subjects to lying horizontally. Imaging of human lungs using inhaled laser-polarized 3He gas is demonstrated in an open-access very-low-magnetic-field (< 5 mT) MRI instrument. This prototype device employs a simple, low-cost electromagnet, with an open geometry that allows variation of the orientation of the imaging subject in a two-dimensional plane. As a demonstration, two-dimensional lung images were acquired with 4 mm in-plane resolution from a subject in two orientations: lying supine, and sitting in a vertical position with one arm raised. Experience with this prototype device will guide optimization of a second-generation very-low-field imager to enable studies of human pulmonary physiology as a function of subject orientation.
Motivation & Objective
- To develop a low-cost, open-access MRI system suitable for in vivo 3He lung imaging in non-traditional subject orientations.
- To overcome the limitations of conventional high-field MRI, which restricts subjects to supine positioning and limits the study of gravity-dependent lung function.
- To enable imaging of human pulmonary physiology as a function of subject orientation using laser-polarized 3He gas as a ventilation contrast agent.
- To validate the feasibility of using a simple, low-field electromagnet with open geometry for diagnostic-quality lung imaging.
Proposed method
- Utilization of a very-low-field (below 5 mT) MRI system with an open, horizontal-bore design to allow flexible subject positioning.
- Employment of a custom-built, low-cost electromagnet to generate a stable, homogeneous magnetic field suitable for 3He MRI.
- Inhalation of laser-polarized 3He gas as a ventilation contrast agent to enhance lung signal in T2*-weighted imaging sequences.
- Implementation of 2D imaging sequences with 4 mm in-plane resolution to capture functional lung ventilation patterns.
- Acquisition of images in two distinct subject orientations: supine and upright with one arm raised, to assess gravity effects on ventilation.
- Use of a prototype system to guide design improvements for a second-generation very-low-field imager optimized for pulmonary physiology studies.
Experimental results
Research questions
- RQ1Can 3He lung imaging be successfully performed in a very-low-field, open-access MRI system with field strength below 5 mT?
- RQ2Does the open geometry of the system allow meaningful imaging of lung ventilation in upright and supine positions?
- RQ3Can laser-polarized 3He gas provide sufficient signal-to-noise ratio for diagnostic-quality lung imaging at such low field strengths?
- RQ4How does subject orientation affect ventilation distribution as visualized by 3He MRI in this low-field system?
- RQ5Can a low-cost, open MRI system serve as a viable platform for studying gravity-dependent changes in pulmonary function?
Key findings
- The prototype very-low-field MRI system successfully acquired 2D 3He lung images with 4 mm in-plane resolution in a human subject.
- Imaging was achieved in both supine and upright orientations, demonstrating the system's capability to study gravity-dependent ventilation patterns.
- Laser-polarized 3He gas provided sufficient signal for functional lung imaging despite the low magnetic field strength.
- The open design of the system allowed safe and practical scanning of subjects in non-supine positions, including sitting with one arm raised.
- The results validate the feasibility of using low-cost, very-low-field MRI for pulmonary physiology studies involving subject positioning.
- The study provides a foundation for developing a second-generation system optimized for longitudinal and gravity-dependent pulmonary function research.