[Paper Review] A Bioimpedance Measurement System for Pulse Wave Analysis
This paper presents a non-invasive, 24-bit, 1000-sample-per-second bioimpedance measurement system using a 50 kHz sinusoidal current injection and synchronized photoplethysmography (PPG) for pulse wave detection. The system successfully captured pulse wave morphology on the forearm with a 40 mΩ impedance change per cardiac cycle, demonstrating feasibility for arterial stiffness assessment without discomfort.
The morphology and velocity of the pulse wave in the arteries provide meaningful information about the cardiovascular system. Nowadays, the pulse wave is usually acquired using common blood pressure cuffs at the extremities. This work describes a new measurement device which detects changes in bioimpedance due to the pulse wave. The system is able to measure up to 1000 bioimpedances per second with a resolution of 24 bits. For comparison purposes, an additional synchronized photoplethysmography circuit is implemented. Initial measurements proved that the system is able to acquire the pulse wave at the forearm.
Motivation & Objective
- To develop a non-invasive, painless method for continuous pulse wave monitoring to assess arterial stiffness.
- To overcome limitations of traditional cuff-based blood pressure measurements, which are uncomfortable and unsuitable for long-term use.
- To enable high-resolution bioimpedance measurement (1000 samples/sec, 24-bit resolution) for improved pulse wave morphology analysis.
- To integrate synchronized PPG as a reference signal for validation and signal comparison.
- To create a portable, low-power system suitable for clinical and long-term monitoring applications.
Proposed method
- A 32-bit microcontroller (SAM4S16C) generates a 50 kHz sinusoidal excitation signal via an internal DAC.
- The signal is filtered using a back-to-back 4th-order Butterworth low-pass and 1st-order high-pass filter to remove DC offset and harmonics.
- A Howland-type voltage-controlled current source (VCCS) delivers a 1 mA AC current into the subject’s tissue through two current electrodes.
- Voltage drops across the tissue and a shunt resistor are measured differentially using an instrumentation amplifier (INA128).
- The differential signals are squared using a multiplier IC (MPY634) and then filtered through a 4th-order active low-pass filter (cutoff 30 Hz).
- A 6-channel, 24-bit ADC (ADS131E06) digitizes both the impedance and PPG signals at 1000 samples per second, with data transferred via USB to a PC for real-time GUI and signal processing.
Experimental results
Research questions
- RQ1Can a high-resolution, non-invasive bioimpedance system detect pulse wave morphology at 1000 samples per second with 24-bit resolution?
- RQ2How does the bioimpedance signal compare to PPG in terms of morphology and timing for pulse wave detection?
- RQ3Can the system reliably capture beat-to-beat changes in tissue impedance during cardiac pulsation?
- RQ4What is the magnitude of impedance variation per cardiac cycle in the forearm using this setup?
- RQ5How do motion artifacts and signal stability affect the measurement in real-world conditions?
Key findings
- The system successfully acquired pulse wave morphology on the forearm of a young, healthy male subject with a sampling rate of 1000 samples per second.
- A consistent impedance change of approximately 40 mΩ was observed per cardiac cycle, indicating detectable pulsatile variation in tissue impedance.
- The bioimpedance signal morphology closely resembled the PPG signal, suggesting reliable detection of arterial pulse waves.
- The bioimpedance signal contained higher-frequency components not present in the PPG signal, indicating potential sensitivity to additional hemodynamic or tissue properties.
- The system demonstrated compatibility with IEC60601-1 safety standards, with a maximum current injection of 1 mA.
- The integration of synchronized PPG enabled effective signal validation and improved confidence in pulse wave detection.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.