Skip to main content
QUICK REVIEW

[Paper Review] A Cloud-Fog Computing Architecture for Real-Time Digital Twins

Francisco Paiva Knebel, Juliano Araújo Wickboldt|arXiv (Cornell University)|Dec 11, 2020
IoT and Edge/Fog ComputingComputer Science31 references6 citations
TL;DR

This paper proposes a cloud-fog computing architecture to reduce latency in real-time Digital Twin systems by distributing processing closer to edge devices. By deploying the MQTT broker and Digital Twin instance on fog nodes, the architecture reduces average message response time by 64% compared to a pure cloud deployment, enabling timely system responses critical for real-time operation.

ABSTRACT

Digital Twin systems are designed as two interconnected mirrored spaces, one real and one virtual, each reflecting the other, sharing information, and making predictions based on analysis and simulations. The correct behavior of a real-time Digital Twin depends not only on the logical results of computation but also on the timing constraints. To cope with the large amounts of data that need to be stored and analyzed, modern large scale Digital Twin deployments often rely on cloud-based architectures. A significant portion of the overall response time of a Digital Twin is spent on moving data from the edge to the cloud. Therefore, implementing Digital Twins using cloud-fog architectures emerges as an alternative to bring computing power closer to the edge, reducing latency and allowing faster response times. This paper studies how suitable the use of a cloud-fog architecture is to handle the real-time requirements of Digital Twins. Based on a realistic implementation and deployment of Digital Twin software components, it is possible to conclude that the distribution of Digital Twins in a fog computing setup can reduce response times, meeting its real-time application requirements.

Motivation & Objective

  • To address the high latency caused by centralized cloud processing in large-scale Digital Twin systems.
  • To evaluate whether fog computing can reduce end-to-end response times in real-time Digital Twin applications.
  • To design and implement a distributed architecture that meets strict real-time timing constraints.
  • To compare performance across three deployment scenarios: cloud-only, cloud-fog hybrid, and fog-only.
  • To demonstrate the feasibility of fog computing in supporting real-time data flow and processing for Digital Twins.

Proposed method

  • The architecture uses MQTT as the messaging protocol for reliable, lightweight communication between sensors and Digital Twin instances.
  • Three deployment scenarios were implemented: (1) all components in the cloud, (2) MQTT broker in fog, Digital Twin in cloud, and (3) both broker and Digital Twin in the same fog node.
  • A client device published sensor data at 80ms intervals, simulating real-time IoT data streams.
  • The system measured end-to-end latency from message publication to twin instance reception across all scenarios.
  • Performance was evaluated based on average, minimum, maximum, and standard deviation of response times per message.
  • Experiments varied message frequency and payload size to assess scalability and real-time responsiveness.

Experimental results

Research questions

  • RQ1Can a cloud-fog architecture reduce end-to-end latency in real-time Digital Twin systems compared to a pure cloud deployment?
  • RQ2How does distributing the MQTT broker and Digital Twin instance across fog nodes affect response time and real-time compliance?
  • RQ3What performance improvements are achievable by processing data closer to the edge in a Digital Twin pipeline?
  • RQ4To what extent does fog computing mitigate the latency bottleneck caused by long-distance data transmission to the cloud?
  • RQ5How do different deployment configurations (cloud-only, cloud-fog, fog-only) impact the timing constraints of real-time Digital Twin applications?

Key findings

  • The fog-only deployment reduced average message response time by 64% compared to the cloud-only scenario, from 182.45ms to 66.08ms.
  • Maximum response time was reduced by 41% in both fog-based scenarios compared to the cloud-only setup.
  • Minimum response time was reduced by 69% in the fog-only scenario, from 111.82ms to 35.13ms.
  • The cloud-fog hybrid scenario reduced average latency by 54% compared to the cloud-only deployment.
  • All fog-based deployments showed significant improvements in standard deviation, indicating more consistent performance.
  • The results confirm that distributing processing closer to the edge is essential for meeting real-time requirements in large-scale Digital Twin systems.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.