[Paper Review] A Comprehensive Study of Alzheimer's Disease Classification Using Convolutional Neural Networks
This study evaluates deep learning models for Alzheimer’s disease classification using full ADNI MRI data, comparing 2D vs. 3D CNNs, pre-training, and model architectures. It finds a 1% accuracy gain with 3D models at high computational cost, minimal benefit from pre-training (<0.5%), and similar performance across popular CNNs, while Clinica preprocessing significantly outperforms FreeSurfer (89% vs. 63% accuracy).
A plethora of deep learning models have been developed for the task of Alzheimer's disease classification from brain MRI scans. Many of these models report high performance, achieving three-class classification accuracy of up to 95%. However, it is common for these studies to draw performance comparisons between models that are trained on different subsets of a dataset or use varying imaging preprocessing techniques, making it difficult to objectively assess model performance. Furthermore, many of these works do not provide details such as hyperparameters, the specific MRI scans used, or their source code, making it difficult to replicate their experiments. To address these concerns, we present a comprehensive study of some of the deep learning methods and architectures on the full set of images available from ADNI. We find that, (1) classification using 3D models gives an improvement of 1% in our setup, at the cost of significantly longer training time and more computation power, (2) with our dataset, pre-training yields minimal ($<0.5\%$) improvement in model performance, (3) most popular convolutional neural network models yield similar performance when compared to each other. Lastly, we briefly compare the effects of two image preprocessing programs: FreeSurfer and Clinica, and find that the spatially normalized and segmented outputs from Clinica increased the accuracy of model prediction from 63% to 89% when compared to FreeSurfer images.
Motivation & Objective
- To objectively compare deep learning models for Alzheimer’s disease classification using consistent data and preprocessing.
- To evaluate the impact of 3D vs. 2D convolutional neural networks on classification accuracy.
- To assess whether pre-training on reconstruction tasks improves classification performance on ADNI MRI data.
- To compare the performance of widely used CNN architectures (e.g., ResNet, DenseNet, InceptionNet) in the context of AD classification.
- To investigate the effect of different MRI preprocessing pipelines—FreeSurfer vs. Clinica—on downstream model accuracy.
Proposed method
- Trained 2D and 3D ResNet architectures on T1-weighted MRI scans from the ADNI dataset, using coronal slices and full 3D volumes.
- Applied data augmentation and class balancing to handle class imbalances in the three-class classification task (CN, MCI, AD).
- Used transfer learning with ImageNet-pretrained weights for 2D models and fine-tuned on MRI data.
- Evaluated pre-training on MRI scans via autoencoder reconstruction before end-to-end classification fine-tuning.
- Compared model performance using the same 3D 16-layer ResNet on two preprocessing pipelines: FreeSurfer (non-normalized) and Clinica (spatially normalized, tissue-segmented).
- Reported validation and test accuracy with standard deviation across multiple random seeds to ensure robustness.
Experimental results
Research questions
- RQ1Does using 3D convolutional neural networks improve classification accuracy compared to 2D models on ADNI MRI scans, and what is the trade-off in training time and computational cost?
- RQ2To what extent does pre-training a CNN on MRI reconstruction tasks improve final classification performance on Alzheimer’s disease?
- RQ3How do popular 2D CNN architectures (e.g., ResNet, DenseNet, InceptionNet, VGG) compare in performance when applied to AD classification on the same dataset?
- RQ4How does the choice of MRI preprocessing pipeline—FreeSurfer vs. Clinica—affect the accuracy of downstream deep learning models?
- RQ5Are architectural innovations like Inception modules or dense connections more impactful than simpler architectures in this specific medical imaging task?
Key findings
- Using 3D ResNet-18 on full 3D gray matter maps improved test accuracy by 1.1% (from 87.4% to 88.5%) compared to 2D ResNet-18 on coronal slices, though training time and GPU memory usage increased significantly.
- Pre-training on MRI reconstruction tasks yielded less than 0.5% improvement in mean test accuracy, indicating minimal benefit in this data regime.
- All major 2D CNN architectures (ResNet-18, DenseNet121, InceptionNet_V3, VGG19_bn) achieved similar performance, with test accuracies ranging from 87.5% to 88.8%.
- Clinica’s spatially normalized and tissue-segmented outputs increased model accuracy to 89.2% on test data, compared to only 63.5% when using FreeSurfer’s non-normalized, skull-stripped outputs.
- The performance gap between Clinica and FreeSurfer was substantial and statistically significant, highlighting the critical role of preprocessing in MRI-based deep learning.
- Despite claims in prior work, architectural complexity (e.g., Inception modules, dense connections) did not yield meaningful performance gains over simpler models in this AD classification task.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.