[Paper Review] A Deep Learning-based Quality Assessment and Segmentation System with a Large-scale Benchmark Dataset for Optical Coherence Tomographic Angiography Image
This paper proposes a deep learning-based computer-aided system, COIPS, for automated quality assessment and foveal avascular zone (FAZ) segmentation in optical coherence tomography angiography (OCTA) images. It leverages a large-scale, publicly available dataset (OCTA-25K-IQA-SEG) and achieves state-of-the-art performance with a Swin-Transformer-Large model attaining 91% accuracy and 92% precision in quality classification, and a U-Net-based model reaching 95% Dice score in FAZ segmentation.
Optical Coherence Tomography Angiography (OCTA) is a non-invasive and non-contacting imaging technique providing visualization of microvasculature of retina and optic nerve head in human eyes in vivo. The adequate image quality of OCTA is the prerequisite for the subsequent quantification of retinal microvasculature. Traditionally, the image quality score based on signal strength is used for discriminating low quality. However, it is insufficient for identifying artefacts such as motion and off-centration, which rely specialized knowledge and need tedious and time-consuming manual identification. One of the most primary issues in OCTA analysis is to sort out the foveal avascular zone (FAZ) region in the retina, which highly correlates with any visual acuity disease. However, the variations in OCTA visual quality affect the performance of deep learning in any downstream marginally. Moreover, filtering the low-quality OCTA images out is both labor-intensive and time-consuming. To address these issues, we develop an automated computer-aided OCTA image processing system using deep neural networks as the classifier and segmentor to help ophthalmologists in clinical diagnosis and research. This system can be an assistive tool as it can process OCTA images of different formats to assess the quality and segment the FAZ area. The source code is freely available at https://github.com/shanzha09/COIPS.git. Another major contribution is the large-scale OCTA dataset, namely OCTA-25K-IQA-SEG we publicize for performance evaluation. It is comprised of four subsets, namely sOCTA-3$ imes$3-10k, sOCTA-6$ imes$6-14k, sOCTA-3$ imes$3-1.1k-seg, and dOCTA-6$ imes$6-1.1k-seg, which contains a total number of 25,665 images. The large-scale OCTA dataset is available at https://doi.org/10.5281/zenodo.5111975, https://doi.org/10.5281/zenodo.5111972.
Motivation & Objective
- To address the clinical challenge of manual, time-consuming, and inconsistent quality assessment of OCTA images due to artifacts like motion, blurring, and off-centration.
- To automate the segmentation of the foveal avascular zone (FAZ), a key biomarker for retinal diseases such as diabetic retinopathy and glaucoma.
- To reduce reliance on manual FAZ measurement, which is labor-intensive and limits large-scale biostatistical studies.
- To develop a generalizable, format-agnostic system that processes diverse OCTA image formats through standardized PNG conversion.
- To provide a publicly accessible, large-scale benchmark dataset (OCTA-25K-IQA-SEG) to accelerate research in OCTA image analysis.
Proposed method
- A deep learning pipeline is developed using multiple backbone architectures—ResNet-101, Inception-V3, EfficientNet-B7, SE-ResNeXt-101, and Swin-Transformer-Large—for OCTA image quality assessment.
- A modified cross-entropy loss function is applied to handle class imbalance in the quality assessment task.
- A U-Net-like architecture based on the nnU-Net framework is used for FAZ segmentation, enabling robust and accurate boundary localization.
- All OCTA images are converted to a unified PNG format to ensure compatibility across different acquisition systems and file types.
- The system performs end-to-end processing: quality scoring, FAZ segmentation, and automated reporting for clinical use.
- The large-scale benchmark dataset, OCTA-25K-IQA-SEG, comprises four subsets totaling 25,665 images, including both quality assessment and segmentation-labeled data.
Experimental results
Research questions
- RQ1Can deep learning models effectively classify OCTA image quality beyond signal strength, particularly for artifacts like motion and off-centration?
- RQ2How accurately can a deep learning model segment the foveal avascular zone (FAZ) across different OCTA image resolutions and field-of-view sizes?
- RQ3To what extent does model performance vary across different OCTA image formats and acquisition protocols?
- RQ4Can a unified deep learning system handle diverse OCTA image inputs and deliver consistent quality assessment and segmentation results?
- RQ5How does the performance of state-of-the-art vision transformers (e.g., Swin-Transformer) compare to CNN-based models in OCTA image quality classification?
Key findings
- The Swin-Transformer-Large model achieved the highest performance in 3×3 mm² sOCTA quality assessment with 91% accuracy, 92% precision, and 91% F1-score.
- For 6×6 mm² dOCTA images, the SE-ResNeXt-101 model achieved 90% accuracy, 90% precision, and 90% F1-score, outperforming other architectures.
- The FAZ segmentation model achieved a Dice coefficient of 0.95 on the sOCTA-3×3-1.1k-seg dataset, indicating high segmentation accuracy.
- On the dOCTA-6×6-1.1k-seg dataset, the model achieved a Dice coefficient of 0.89, reflecting slightly lower performance due to less distinct vessel boundaries.
- The proposed COIPS system demonstrated strong generalization across different image formats and field-of-view sizes, enabling automated, reliable, and efficient processing.
- The publicly released OCTA-25K-IQA-SEG dataset is the largest benchmark in the field to date, comprising 25,665 labeled OCTA images for quality assessment and segmentation.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.