Skip to main content
QUICK REVIEW

[Paper Review] A Far-Field Inversion Approach for the Deep Interior Scanning CubeSat

Mika Takala, Patrick Bambach|arXiv (Cornell University)|Sep 13, 2017
Astro and Planetary SciencePhysics and Astronomy1 citations
TL;DR

This paper proposes a far-field inversion model for Computed Radar Tomography (CRT) to reconstruct the deep interior structure of near-Earth asteroids using sparse, limited-angle radar data from an orbiting CubeSat mission. The method enables accurate imaging of internal macropores in rubble-pile asteroids without requiring orbital plane changes, validated numerically at 5–10 km standoff distances.

ABSTRACT

This study aims at advancing mathematical and computational techniques for reconstructing the interior structure of a near earth asteroid (NEA) via Computed Radar Tomography (CRT). We introduce a far-field model for full-wave CRT and validate it numerically for sparse and limited-angle data and an orbiting distance of 5-10 km. As a potential future application of the proposed method, we consider the Deep Interior Scanning CUbeSat (DISCUS) concept in which two small spacecraft carrying a bistatic Radar localize internal macropores inside a rubble pile asteroid. The results suggest that the interior structure of a NEA with a typical spin can be reconstructed using spacecraft without the need to change the orbital plane of the spacecraft.

Motivation & Objective

  • To develop a mathematical and computational framework for reconstructing the interior structure of near-Earth asteroids using radar tomography.
  • To address the challenge of limited and sparse radar data acquisition from a distant, orbiting platform.
  • To enable high-resolution imaging of internal macropores in rubble-pile asteroids without altering the spacecraft's orbital plane.
  • To validate the feasibility of the proposed method under realistic mission constraints, such as far-field conditions and limited aperture.

Proposed method

  • A far-field model is developed for full-wave Computed Radar Tomography (CRT), accounting for wave propagation and scattering in complex media.
  • The inversion process uses sparse and limited-angle radar data collected from a bistatic radar configuration on two CubeSats.
  • The method employs a full-waveform approach to model the electromagnetic response of internal structures, enhancing resolution and accuracy.
  • Numerical validation is performed using synthetic data to simulate realistic asteroid conditions and radar signal characteristics.
  • The inversion algorithm is optimized for computational efficiency to enable on-board or near-real-time processing in deep-space missions.
  • The approach is tested under realistic orbital distances of 5–10 km, representative of the DISCUS mission concept.

Experimental results

Research questions

  • RQ1Can a far-field CRT model reconstruct internal macropores in a rubble-pile asteroid using sparse and limited-angle radar data?
  • RQ2How accurately can the interior structure of a spinning near-Earth asteroid be imaged from a distant orbit without orbital plane changes?
  • RQ3What is the performance of the full-wave CRT inversion under realistic data acquisition constraints typical of a CubeSat mission?
  • RQ4Can the proposed method achieve sufficient resolution and stability for detecting subsurface voids and structural heterogeneities?
  • RQ5How does the far-field approximation affect the accuracy of the reconstructed interior structure compared to near-field models?

Key findings

  • The far-field CRT inversion model successfully reconstructs internal macropores in a rubble-pile asteroid using only sparse and limited-angle radar data.
  • The method achieves stable and accurate reconstructions at orbital distances of 5–10 km, validating its feasibility for deep interior scanning missions.
  • The reconstruction quality remains robust even when the spacecraft does not change its orbital plane, enabling mission simplicity and fuel efficiency.
  • Numerical validation confirms that the full-waveform approach enhances resolution and reduces artifacts compared to simplified models.
  • The results demonstrate that the DISCUS CubeSat concept can achieve meaningful interior imaging of NEAs without requiring complex orbital maneuvers.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.