Skip to main content
QUICK REVIEW

[Paper Review] A Generalized Motion Pattern and FCN based approach for retinal fluid detection and segmentation

Shivin Yadav, Karthik Gopinath|arXiv (Cornell University)|Dec 4, 2017
Retinal Imaging and AnalysisMedicine3 references13 citations
TL;DR

This paper proposes a fully automated, scanner-independent method for retinal fluid detection and segmentation in SD-OCT scans using a cascaded fully convolutional network (FCN) driven by Generalized Motion Pattern (GMP) features. The GMP enhances fluid abnormalities and suppresses noise by applying multi-directional image translations and minimum pooling, enabling robust segmentation across diverse scanners and achieving mean Dice scores of 0.61, 0.70, and 0.73 for IRF, SRF, and PED, respectively, with AUCs of 0.85, 0.84, and 0.87 for detection.

ABSTRACT

SD-OCT is a non-invasive cross-sectional imaging modality used for diagnosis of macular defects. Efficient detection and segmentation of the abnormalities seen as biomarkers in OCT can help in analyzing the progression of the disease and advising effective treatment for the associated disease. In this work, we propose a fully automated Generalized Motion Pattern(GMP) based segmentation method using a cascade of fully convolutional networks for detection and segmentation of retinal fluids from SD-OCT scans. General methods for segmentation depend on domain knowledge-based feature extraction, whereas we propose a method based on Generalized Motion Pattern (GMP) which is derived by inducing motion to an image to suppress the background.The proposed method is parallelizable and handles inter-scanner variability efficiently. Our method achieves a mean Dice score of 0.61,0.70 and 0.73 during segmentation and a mean AUC of 0.85,0.84 and 0.87 during detection for the 3 types of fluids IRF, SRF and PDE respectively.

Motivation & Objective

  • To develop a fully automated, scanner-independent method for detecting and segmenting retinal fluid abnormalities in SD-OCT scans.
  • To overcome limitations of domain-specific feature engineering by introducing a generalized, motion-based feature enhancement technique.
  • To improve segmentation accuracy across diverse OCT scanners and reduce sensitivity to inter-scanner intensity and resolution variability.
  • To enable joint detection and segmentation using a cascaded FCN architecture trained on GMP-enhanced features.
  • To minimize false positives through multi-scale post-processing and volume-level consistency modeling.

Proposed method

  • Preprocess SD-OCT volumes by resizing to 512×256, denoising with spectral total variation, and extracting a 256×256 ROI around the brightest column-wise pixel.
  • Generate Generalized Motion Pattern (GMP) images by applying rigid translations (step size δ=1, range D=5) at multiple angles (θ), then combining results via minimum pooling to enhance darker fluid regions.
  • Construct an ensemble of GMP images across multiple directions to improve robustness to variable fluid orientation and size.
  • Train a cascaded FCN with two stages: first for slice-wise segmentation, second for refinement, using negative Dice coefficient as loss.
  • Apply post-processing: threshold predictions, remove small connected components, and cluster fluid regions in intensity space to eliminate false positives.
  • Use k-nearest neighbor slice analysis (k=3) to detect fluid presence across volumes, leveraging 3D persistence to reduce false positives in detection.

Experimental results

Research questions

  • RQ1Can a generalized motion pattern (GMP) effectively enhance retinal fluid abnormalities in SD-OCT scans while suppressing noise and background structures?
  • RQ2How does the cascaded FCN architecture with GMP input compare to traditional domain-specific feature-based segmentation methods in terms of accuracy and robustness?
  • RQ3To what extent does the proposed method generalize across different OCT scanner vendors with varying intensity profiles and resolutions?
  • RQ4Why does the method perform less accurately on IRF compared to SRF and PED, and can this be mitigated through post-processing or model adaptation?
  • RQ5Can volume-level consistency in fluid presence across adjacent slices improve detection reliability compared to slice-wise segmentation alone?

Key findings

  • The proposed method achieves a mean Dice score of 0.61, 0.70, and 0.73 for IRF, SRF, and PDE segmentation, respectively, across all scanners.
  • The detection task yields mean AUC scores of 0.85, 0.84, and 0.87 for IRF, SRF, and PDE, indicating strong performance in identifying fluid presence.
  • The method demonstrates robustness to inter-scanner variability, with high AUC and Dice scores maintained across Cirrus, Spectralis, and Topcon OCT devices.
  • Performance is lower for IRF compared to SRF and PED, likely due to IRF's noise-like appearance that gets enhanced during GMP construction.
  • Post-processing significantly reduces false positives by filtering small connected components and clustering based on intensity, improving segmentation fidelity.
  • Volume-level analysis (k=3 neighboring slices) enhances detection reliability by leveraging the 3D persistence of fluid structures, reducing false positives in detection.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint