[Paper Review] A liquid nitrogen-cooled Ca^+ optical clock with systematic uncertainty of 3*10^-18
This paper presents a liquid nitrogen-cooled 40Ca+ optical clock achieving a systematic uncertainty of 3×10⁻¹⁸, significantly reducing blackbody radiation (BBR) shift by cooling the BBR shield to 82(5) K. By employing a low-heating-rate ion trap, improved cooling lasers, the hyper-Ramsey method, and a higher-order servo algorithm, the authors suppress motion and laser-related shifts to below 1×10⁻¹⁸ and 4×10⁻¹⁹, respectively, demonstrating a practical, cost-effective alternative to liquid-helium systems.
Here we present a liquid nitrogen-cooled Ca^+ optical clock with an overall systematic uncertainty of 3*10^-18. In contrast with the room-temperature Ca^+ optical clock that we have reported previously, the temperature of the blackbody radiation (BBR) shield in vacuum has been reduced to 82(5) K using liquid nitrogen. An ion trap with a lower heating rate and improved cooling lasers were also introduced. This allows cooling the ion temperature to the Doppler cooling limit during the clock operation, and the systematic uncertainty due to the ion's secular (thermal) motion is reduced to < 1*10^-18. The uncertainty due to the probe laser light shift and the servo error are also reduced to < 1*10^-19 and 4*10^-19 with the hyper-Ramsey method and the higher-order servo algorithm, respectively. By comparing the output frequency of the cryogenic clock to that of a room-temperature clock, the differential BBR shift between the two was measured with a fractional statistical uncertainty of 7*10^-18. The differential BBR shift was used to calculate the static differential polarizability, and it was found in excellent agreement with our previous measurement with a different method. This work suggests that the BBR shift of optical clocks can be well suppressed in a liquid nitrogen environment. This is advantageous because conventional liquid-helium cryogenic systems for optical clocks are more expensive and complicated. Moreover, the proposed system can be used to suppress the BBR shift significantly in other types of optical clocks such as Yb^+, Sr^+, Yb, Sr, etc.
Motivation & Objective
- To reduce the systematic uncertainty of a 40Ca+ optical clock below 10⁻¹⁸ for improved timekeeping precision.
- To suppress blackbody radiation (BBR) shift by cooling the BBR shield to 82(5) K using liquid nitrogen instead of liquid helium.
- To minimize ion motion and laser light shift uncertainties through improved trap design and advanced laser control techniques.
- To validate the BBR shift measurement via differential comparison with a room-temperature clock and determine static differential polarizability.
- To demonstrate the feasibility of using liquid nitrogen cooling as a scalable, low-cost alternative to conventional cryogenic systems in optical clocks.
Proposed method
- Cooling the BBR shield in vacuum to 82(5) K using liquid nitrogen to suppress blackbody radiation shifts.
- Implementing an ion trap with a lower heating rate to reduce thermal motion of the 40Ca+ ion.
- Using improved cooling lasers to achieve Doppler cooling limit, minimizing secular motion-induced frequency shifts.
- Applying the hyper-Ramsey method to reduce probe laser light shift uncertainty to below 1×10⁻¹⁹.
- Employing a higher-order servo algorithm to reduce servo error to 4×10⁻¹⁹.
- Measuring the differential BBR shift between the cryogenic and room-temperature clocks with a fractional statistical uncertainty of 7×10⁻¹⁸.
Experimental results
Research questions
- RQ1Can liquid nitrogen cooling effectively suppress blackbody radiation shifts in a 40Ca+ optical clock?
- RQ2To what extent can ion motion and laser control uncertainties be reduced using improved trap and laser systems?
- RQ3How accurately can the differential BBR shift be measured between a cryogenic and a room-temperature optical clock?
- RQ4Is the static differential polarizability derived from the differential BBR shift consistent with previous measurements?
- RQ5Can liquid nitrogen cooling serve as a practical, cost-effective alternative to liquid helium systems in optical clocks?
Key findings
- The overall systematic uncertainty of the liquid nitrogen-cooled 40Ca+ optical clock is 3×10⁻¹⁸.
- The BBR shift is suppressed by cooling the shield to 82(5) K, significantly reducing thermal radiation effects.
- Ion motion-induced frequency shift is reduced to less than 1×10⁻¹⁸ through Doppler cooling and low-heating-rate trap design.
- Laser light shift uncertainty is reduced to below 1×10⁻¹⁹ using the hyper-Ramsey method.
- Servo error is reduced to 4×10⁻¹⁹ with the higher-order servo algorithm.
- The differential BBR shift is measured with a fractional statistical uncertainty of 7×10⁻¹⁸, enabling precise determination of static differential polarizability consistent with prior results.