This paper proposes a novel classification framework for recognizing three fundamental robotic surgical tasks—suturing, knot tying, and needle passing—using only 3D Cartesian motion trajectories from the da Vinci surgical system. By combining derivative dynamic time warping (DDTW) and distance-weighted k-nearest neighbors (k-NN), the method achieves 99.4% accuracy in task recognition, demonstrating that temporal motion patterns are highly discriminative for surgical task classification.
Automatic recognition and classification of tasks in robotic surgery is an important stepping stone toward automated surgery and surgical training. Recently, technical breakthroughs in gathering data make data-driven model development possible. In this paper, we propose a framework for high-level robotic surgery task recognition using motion data. We present a novel classification technique that is used to classify three important surgical tasks through quantitative analyses of motion: knot tying, needle passing and suturing. The proposed technique integrates state-of-the-art data mining and time series analysis methods. The first step of this framework consists of developing a time series distance-based similarity measure using derivative dynamic time warping (DDTW). The distance-weighted k-nearest neighbor algorithm was then used to classify task instances. The framework was validated using an extensive dataset. Our results demonstrate the strength of the proposed framework in recognizing fundamental robotic surgery tasks.
Motivation & Objective
- To develop a data-driven framework for automatic recognition of high-level robotic surgical tasks using motion data.
- To address the challenge of classifying fundamental surgical tasks such as suturing, knot tying, and needle passing with minimal human intervention.
- To evaluate the effectiveness of time series similarity measures—specifically DTW and DDTW—in capturing discriminative features of surgical motion.
- To establish a simple yet accurate method for surgical task recognition using only tool tip position data, avoiding reliance on video or complex preprocessing.
Proposed method
- The framework uses 3D Cartesian motion trajectories from both the right and left surgical instruments as input data.
- A time series distance-based similarity measure is constructed using Derivative Dynamic Time Warping (DDTW) to align and compare motion sequences.
- The DDTW method enhances alignment robustness by focusing on the derivative of the motion signal, reducing sensitivity to local peaks and valleys.
- Distance-weighted k-Nearest Neighbors (k-NN) is employed for classification, where each test instance is classified based on the weighted votes of its k most similar training instances.
- Cross-validation techniques (10-fold and leave-one-out) are used to evaluate model performance and ensure generalization.
- The method is trained and tested on a real-world dataset collected from da Vinci surgical systems, focusing on kinematic data only.
Experimental results
Research questions
- RQ1Can motion trajectory data from robotic surgical systems be effectively used to classify high-level surgical tasks without video or visual cues?
- RQ2How do DTW and DDTW compare in capturing discriminative features of surgical tasks like suturing, knot tying, and needle passing?
- RQ3Does the inclusion of derivative information in DDTW improve classification accuracy compared to standard DTW in this domain?
- RQ4To what extent can a simple k-NN classifier with time series similarity measures achieve high accuracy in surgical task recognition?
- RQ5Are the temporal motion patterns of fundamental robotic surgery tasks sufficiently distinct to allow reliable classification across different surgeons and skill levels?
Key findings
- The proposed framework achieved a highest classification accuracy of 99.4% using DTW with leave-one-out cross-validation on both-hand motion data.
- DTW outperformed DDTW consistently across all evaluation settings, indicating that local peaks and valleys in tool tip trajectories are meaningful discriminative features for surgical tasks.
- For both-hand motion data, DTW-k-NN achieved 99.28% accuracy with 10-fold cross-validation and 99.40% with leave-one-out validation, with low standard deviation (0.00% in LOO), indicating high stability.
- The method demonstrated robustness across different surgeons, as all tasks showed high specificity and only one knot tying instance was misclassified as needle passing.
- Despite DDTW’s theoretical advantage in handling noise, it underperformed DTW, suggesting that the raw motion dynamics contain critical information for task differentiation.
- The results confirm that time series features of suturing, knot tying, and needle passing are sufficiently distinct to enable accurate, data-driven classification using only kinematic trajectories.