Skip to main content
QUICK REVIEW

[Paper Review] A New Window Loss Function for Bone Fracture Detection and Localization in X-ray Images with Point-based Annotation

Xinyu Zhang, Yirui Wang|arXiv (Cornell University)|Dec 7, 2020
COVID-19 diagnosis using AIMedicine32 references7 citations
TL;DR

This paper proposes a novel Window Loss function for bone fracture detection and localization in pelvic X-ray images using point-based annotations, which better handle the ambiguity of fracture boundaries. By converting point annotations into pixel-wise supervision with lower/upper bounds and uncertain regions, the method achieves state-of-the-art performance with an AUROC of 0.983 and FROC score of 89.6% on 4,410 pelvic X-ray images.

ABSTRACT

Object detection methods are widely adopted for computer-aided diagnosis using medical images. Anomalous findings are usually treated as objects that are described by bounding boxes. Yet, many pathological findings, e.g., bone fractures, cannot be clearly defined by bounding boxes, owing to considerable instance, shape and boundary ambiguities. This makes bounding box annotations, and their associated losses, highly ill-suited. In this work, we propose a new bone fracture detection method for X-ray images, based on a labor effective and flexible annotation scheme suitable for abnormal findings with no clear object-level spatial extents or boundaries. Our method employs a simple, intuitive, and informative point-based annotation protocol to mark localized pathology information. To address the uncertainty in the fracture scales annotated via point(s), we convert the annotations into pixel-wise supervision that uses lower and upper bounds with positive, negative, and uncertain regions. A novel Window Loss is subsequently proposed to only penalize the predictions outside of the uncertain regions. Our method has been extensively evaluated on 4410 pelvic X-ray images of unique patients. Experiments demonstrate that our method outperforms previous state-of-the-art image classification and object detection baselines by healthy margins, with an AUROC of 0.983 and FROC score of 89.6%.

Motivation & Objective

  • To address the limitations of bounding box annotations for bone fractures, which are ambiguous due to complex morphology and lack of clear boundaries.
  • To develop a cost-effective and flexible annotation scheme suitable for pathologies with ill-defined spatial extents.
  • To improve both classification and localization performance in bone fracture detection using a new loss function tailored to point-based supervision.
  • To validate the effectiveness of pixel-wise supervision with lower and upper bounds and uncertain regions in improving model robustness and accuracy.

Proposed method

  • Uses point-based annotations to mark localized fracture locations, avoiding the need for precise bounding boxes.
  • Converts point annotations into pixel-wise supervision using lower and upper bounds: positive (within lower radius), uncertain (between lower and upper radius), and negative (beyond upper radius).
  • Proposes a novel Window Loss that only penalizes predictions outside the uncertain regions, reducing false positives in normal areas.
  • Employs a deep learning model with global average pooling and fully convolutional networks for end-to-end training.
  • Uses mean squared error (MSE) and Kullback–Leibler divergence (KLD) as divergence measures in the loss function.
  • Applies feature pyramid networks (FPN) to enhance multi-scale feature learning for improved localization.

Experimental results

Research questions

  • RQ1Can point-based annotations effectively represent bone fractures in X-ray images where bounding boxes are ambiguous?
  • RQ2How does a window loss that penalizes only outside predictions improve localization accuracy compared to standard losses?
  • RQ3What is the optimal configuration of lower bound radius (rℓ), upper bound radius (ru), and smoothing parameter (τ) for the Window Loss?
  • RQ4Does modeling uncertainty through bounded regions lead to better generalization and robustness in fracture detection?

Key findings

  • The proposed method achieves an AUROC of 0.983 and a FROC score of 89.6% on 4,410 pelvic X-ray images, outperforming state-of-the-art image classification and object detection baselines.
  • Ablation studies show that the default setting (rℓ=50, ru=200, τ=2) yields the best balance between classification and localization performance.
  • Increasing rℓ from 50 to 150 reduces FROC by 7.9% (MSE) and 6.8% (KLD), indicating that larger positive regions degrade localization due to inclusion of normal tissue.
  • Higher τ values (e.g., τ=10) significantly degrade localization, reducing Recall@0.1 from 87.4% to 69.6% (MSE), due to overly smoothed supervision.
  • The degenerate case with τ=0 (binary mask) achieves AUROC 0.980 and FROC 85.4%, demonstrating that even simplified supervision outperforms standard methods.
  • The method maintains high AUROC (0.984–0.986) across ablation settings, indicating robustness to parameter variations.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.