[Paper Review] A novel and reliable deep learning web-based tool to detect COVID-19 infection form chest CT-scan

Abdolkarim Saeedi, Maryam Saeedi|arXiv (Cornell University)|Jun 24, 2020
COVID-19 diagnosis using AIMedicine5 references13 citations
TL;DR

This paper presents a reliable web-based deep learning tool for detecting COVID-19 from chest CT scans using a hybrid model combining DenseNet for feature extraction and Nu-SVM for classification. The system achieves 90.61% accuracy, 90.80% recall, 89.76% precision, and an AUC of 95.05%, with inference taking only 39 milliseconds per image.

ABSTRACT

The corona virus is already spread around the world in many countries, and it has taken many lives. Furthermore, the world health organization (WHO) has announced that COVID-19 has reached the global epidemic stage. Early and reliable diagnosis using chest CT-scan can assist medical specialists in vital circumstances. In this work, we introduce a computer aided diagnosis (CAD) web service to detect COVID- 19 online. One of the largest public chest CT-scan databases, containing 746 participants was used in this experiment. A number of well-known deep neural network architectures consisting of ResNet, Inception and MobileNet were inspected to find the most efficient model for the hybrid system. A combination of the Densely connected convolutional network (DenseNet) in order to reduce image dimensions and Nu-SVM as an anti-overfitting bottleneck was chosen to distinguish between COVID-19 and healthy controls. The proposed methodology achieved 90.80% recall, 89.76% precision and 90.61% accuracy. The method also yields an AUC of 95.05%. Ultimately a flask web service is made public through ngrok using the trained models to provide a RESTful COVID-19 detector, which takes only 39 milliseconds to process one image. The source code is also available at this https URL. Based on the findings, it can be inferred that it is feasible to use the proposed technique as an automated tool for diagnosis of COVID-19.

Motivation & Objective

  • To develop an automated, reliable, and accessible web-based tool for early detection of COVID-19 using chest CT-scan images.
  • To address the challenge of timely and accurate diagnosis during the global COVID-19 pandemic by leveraging deep learning.
  • To improve diagnostic efficiency for medical specialists by reducing reliance on manual interpretation of CT scans.
  • To create a publicly available, low-latency, RESTful web service for real-time COVID-19 detection.

Proposed method

  • A hybrid deep learning model was developed using DenseNet to extract hierarchical features from chest CT scans and reduce image dimensions.
  • Nu-SVM was employed as a classifier to act as an anti-overfitting bottleneck, enhancing generalization.
  • The model was trained and validated on a public dataset of 746 participants, including both COVID-19 positive and healthy control cases.
  • Multiple deep neural networks (ResNet, Inception, MobileNet) were evaluated to select the most efficient architecture for the hybrid system.
  • A Flask-based web service was deployed using ngrok to host the trained model, enabling public access via REST API.
  • The system processes a single CT image in just 39 milliseconds, ensuring real-time performance.

Experimental results

Research questions

  • RQ1Can a deep learning-based web service achieve high accuracy and low latency in detecting COVID-19 from chest CT scans?
  • RQ2Which deep neural network architecture performs best when combined with a Nu-SVM classifier for this diagnostic task?
  • RQ3Is it feasible to deploy a reliable, publicly accessible web-based CAD system for COVID-19 detection using CT imaging?
  • RQ4How effective is the hybrid DenseNet-Nu-SVM model in minimizing overfitting while maintaining high diagnostic performance?

Key findings

  • The proposed web-based CAD system achieved 90.61% accuracy in distinguishing between COVID-19 and healthy controls on the test set.
  • The model demonstrated a high recall of 90.80%, indicating strong sensitivity in detecting positive cases.
  • Precision was recorded at 89.76%, showing reliable positive predictions with minimal false positives.
  • The area under the ROC curve (AUC) reached 95.05%, indicating excellent overall diagnostic discrimination.
  • The system processes a single CT image in only 39 milliseconds, enabling real-time deployment in clinical settings.
  • The source code and trained models are publicly available, supporting transparency and reproducibility.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.