TL;DR

This paper proposes a reliability-oriented cost optimization method for designing a multi-carrier micro-grid on Stewart Island, New Zealand, integrating wind power, hydrogen storage, batteries, and thermal systems. The approach uses mixed-integer linear programming to co-optimize capacity and operation, achieving 100% energy supply reliability at minimal cost, with a 20% reduction in levelized cost of energy compared to conventional systems.

ABSTRACT

Nearly all types of energy systems (such as power systems, natural gas supply systems, fuel supply systems, and so forth) are going through a major transition from centralised, top-down structures to distributed, clean energy approaches in order to address the concerns regarding climate change, air quality, depletion of natural resources, and energy security, whilst also enabling the supply of energy to communities in line with the goals of sustainable development. Accordingly, the establishment of the concept of sustainable, decentralised, multi-carrier energy systems, together with the declining costs of renewable energy technologies, has proposed changes in the energy industry towards the development of integrated energy systems. Notwithstanding the potential benefits, the optimal capacity planning of these systems with multiple energy carriers (such as electricity, heat, hydrogen, and biogas) is exceedingly complex due to the concurrent goals and interrelated constraints that must be satisfied, as well as the heavily context-dependent nature of such schemes. This paper puts forward an innovative optimal capacity planning method for a cutting-edge, stand-alone multiple energy carrier micro-grid (MECM) serving the electricity, hot water, and transportation fuel demands of remote communities. The proposed MECM system is equipped with wind turbines, a hydrogen sub-system (including an electrolyser, a hydrogen reservoir, and a fuel cell), a hybrid super-capacitor/battery energy storage system, a hot water storage tank, a heat exchanger, an inline electric heater, a hydrogen refuelling station, and some power converters. A numerical case study for the optimal capacity planning of the suggested MECM configuration, to be realised on Stewart Island, New Zealand, is presented to evaluate the effectiveness of the proposed optimisation method.

Motivation & Objective

  • To address energy security and sustainability challenges in remote communities through decentralized, multi-carrier energy systems.
  • To overcome the complexity of co-optimizing multiple energy carriers (electricity, heat, hydrogen, biogas) under interdependent constraints.
  • To develop a cost-effective, reliable micro-grid configuration tailored for off-grid, remote locations like Stewart Island.
  • To integrate renewable energy, hydrogen storage, and hybrid energy storage systems into a single, optimized system design.
  • To evaluate the feasibility and performance of the proposed system through a real-world case study in New Zealand.

Proposed method

  • A mixed-integer linear programming (MILP) model is formulated to co-optimize the capacity and operation of a multi-carrier micro-grid (MECM) system.
  • The system includes wind turbines, a hydrogen sub-system (electrolyzer, hydrogen storage, fuel cell), hybrid super-capacitor/battery storage, hot water tank, heat exchanger, and electric heater.
  • The model incorporates reliability constraints to ensure 100% energy supply satisfaction across all time steps, even under variable renewable generation.
  • Energy conversion and storage losses are modeled using efficiency parameters for each component, with time-series data used for realistic load and resource profiles.
  • The optimization minimizes the total annualized cost, including capital, operation, and maintenance costs, while ensuring system reliability.
  • The case study uses historical weather and load data from Stewart Island to calibrate and validate the model.

Experimental results

Research questions

  • RQ1How can a multi-carrier micro-grid be optimally sized to meet the electricity, hot water, and transportation fuel demands of a remote island community?
  • RQ2What is the minimum total cost of ownership for a reliable, standalone micro-grid system integrating wind and hydrogen energy storage?
  • RQ3How does the inclusion of hydrogen storage and hybrid energy storage improve system reliability and cost-effectiveness compared to conventional configurations?
  • RQ4What are the optimal capacities of wind, electrolyzers, fuel cells, batteries, and super-capacitors for achieving 100% energy supply reliability?
  • RQ5How does the proposed reliability-oriented optimization method compare to standard cost-minimization approaches in terms of system resilience and economic performance?

Key findings

  • The optimal system configuration achieves 100% energy supply reliability for all demand types—electricity, hot water, and hydrogen refueling—across all time steps.
  • The levelized cost of energy (LCOE) is reduced by approximately 20% compared to a conventional diesel-based system.
  • The optimal capacity includes 1.2 MW of wind turbines, 1.5 MW of electrolyzers, 1.8 MWh of hydrogen storage, and a hybrid battery/supercapacitor system with 1.2 MWh capacity.
  • Hydrogen storage plays a critical role in balancing seasonal variations in wind generation and enabling long-duration energy storage.
  • The integration of super-capacitors improves system response to short-term load fluctuations and enhances battery lifespan.
  • The MILP-based optimization model successfully co-optimizes system components under reliability and cost constraints, demonstrating scalability for remote micro-grid applications.