[Paper Review] A Review on Deep-Learning Algorithms for Fetal Ultrasound-Image Analysis
This paper provides a comprehensive, up-to-date review of deep learning (DL) applications in fetal ultrasound image analysis, covering 145 recent studies (2017–2023). It systematically categorizes methods into standard-plane detection, anatomical-structure analysis, and biometry estimation, evaluates performance metrics and public datasets, and identifies key challenges such as data scarcity, lack of federated learning adoption, and insufficient ethical compliance in DL research for fetal US.
Deep-learning (DL) algorithms are becoming the standard for processing ultrasound (US) fetal images. Despite a large number of survey papers already present in this field, most of them are focusing on a broader area of medical-image analysis or not covering all fetal US DL applications. This paper surveys the most recent work in the field, with a total of 145 research papers published after 2017. Each paper is analyzed and commented on from both the methodology and application perspective. We categorized the papers in (i) fetal standard-plane detection, (ii) anatomical-structure analysis, and (iii) biometry parameter estimation. For each category, main limitations and open issues are presented. Summary tables are included to facilitate the comparison among the different approaches. Publicly-available datasets and performance metrics commonly used to assess algorithm performance are summarized, too. This paper ends with a critical summary of the current state of the art on DL algorithms for fetal US image analysis and a discussion on current challenges that have to be tackled by researchers working in the field to translate the research methodology into the actual clinical practice.
Motivation & Objective
- To provide a focused, up-to-date review of deep learning applications specifically in fetal ultrasound image analysis, addressing gaps in existing broader surveys.
- To categorize and analyze recent DL methods in three core clinical tasks: standard-plane detection, anatomical-structure analysis, and biometry parameter estimation.
- To evaluate publicly available datasets and performance metrics used in the field, supporting reproducibility and benchmarking.
- To identify persistent limitations and open challenges—such as data privacy, lack of federated learning, and ethical compliance—in translating DL research into clinical practice.
- To guide researchers by summarizing methodological pros and cons, performance outcomes, and future research directions in fetal US DL.
Proposed method
- The review systematically analyzed 145 peer-reviewed journal and conference papers published from 2017 onward, selected via keyword-based searches across IEEEXplore, Scopus, SpringerLink, ScienceDirect, and PubMed.
- Papers were categorized into three main clinical tasks: (i) fetal standard-plane detection, (ii) anatomical-structure analysis, and (iii) biometry parameter estimation, with additional coverage of emerging tasks in a miscellaneous section.
- For each category, methods were evaluated based on their technical approach (e.g., CNNs, YOLO, U-Net, GANs, transformers), performance metrics (e.g., Dice, IoU, AUC, RMSE), and dataset characteristics.
- Summary tables were constructed to compare training/test set sizes, number of annotators, and reported performance across studies, enabling cross-method benchmarking.
- The review assessed publicly available datasets (e.g., from Grand Challenge, ISBI, or institutional collections) and standard performance metrics (e.g., accuracy, F1-score, RMSE) used in the literature.
- Ethical and methodological challenges—such as lack of adherence to the EU’s Ethics Guidelines for Trustworthy AI and absence of federated learning—were critically discussed based on survey findings.
Experimental results
Research questions
- RQ1What are the most actively researched tasks in fetal ultrasound image analysis using deep learning, and how have they evolved since 2017?
- RQ2Which deep learning architectures and performance metrics are most commonly used across different tasks (e.g., detection, segmentation, biometry)?
- RQ3To what extent are publicly available datasets sufficient and representative for training robust and generalizable DL models in fetal US?
- RQ4What are the key limitations and open challenges—especially in data privacy, model generalization, and ethical AI—preventing clinical translation of DL methods in fetal ultrasound?
- RQ5Why is federated learning underutilized in fetal US DL research despite its potential to address data-sharing and privacy concerns?
Key findings
- The majority of recent DL research in fetal ultrasound focuses on standard-plane detection (e.g., 4CH, 3VV, FLVSP), with YOLO-based models achieving high mAP values (e.g., >0.90) on benchmark datasets.
- U-Net and its variants remain dominant in anatomical-structure segmentation tasks, with Dice scores often exceeding 0.85 for structures like the fetal brain and ventricles.
- Biometry parameter estimation (e.g., BPD, HC, AC) using CNNs and regression heads achieves low RMSE values (e.g., <2 mm for BPD and AC), indicating high accuracy for clinical use.
- Despite strong performance in controlled settings, most models show limited generalization across different scanners, protocols, and patient populations due to dataset bias and lack of diversity.
- Only 18% of reviewed papers reported using datasets with more than 100 scans, and no study employed federated learning, despite its potential for privacy-preserving multi-center collaboration.
- No paper in the survey explicitly addressed ethical compliance with the EU’s Ethics Guidelines for Trustworthy AI, including missing assessment checklists or transparency reports.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.