Skip to main content
QUICK REVIEW

[Paper Review] A Robot for Nondestructive Assay of Holdup Deposits in Gaseous Diffusion Piping

Heather Jones, Siri Maley|arXiv (Cornell University)|Jan 29, 2019
Geophysical Methods and ApplicationsEngineering1 references4 citations
TL;DR

This paper presents the RadPiper robot, an autonomous in-pipe system that enables nondestructive assay of uranium-235 holdup deposits in gaseous diffusion enrichment facilities. Equipped with a disc-collimated NaI scintillation detector, it measures radiation from inside pipes, significantly increasing count rates and measurement accuracy while enhancing operator safety and reducing decommissioning time compared to traditional external methods.

ABSTRACT

Miles of contaminated pipe must be measured, foot by foot, as part of the decommissioning effort at deactivated gaseous diffusion enrichment facilities. The current method requires cutting away asbestos-lined thermal enclosures and performing repeated, elevated operations to manually measure pipe from the outside. The RadPiper robot, part of the Pipe Crawling Activity Measurement System (PCAMS) developed by Carnegie Mellon University and commissioned for use at the DOE Portsmouth Gaseous Diffusion Enrichment Facility, automatically measures U-235 in pipes from the inside. This improves certainty, increases safety, and greatly reduces measurement time. The heart of the RadPiper robot is a sodium iodide scintillation detector in an innovative disc-collimated assembly. By measuring from inside pipes, the robot significantly increases its count rate relative to external through-pipe measurements. The robot also provides imagery, models interior pipe geometry, and precisely measures distance in order to localize radiation measurements. Data collected by this system provides insight into pipe interiors that is simply not possible from exterior measurements, all while keeping operators safer. This paper describes the technical details of the PCAMS RadPiper robot. Key features for this robot include precision distance measurement, in-pipe obstacle detection, ability to transform for two pipe sizes, and robustness in autonomous operation. Test results demonstrating the robot's functionality are presented, including deployment tolerance tests, safeguarding tests, and localization tests. Integrated robot tests are also shown.

Motivation & Objective

  • To develop a safer and more efficient method for measuring uranium-235 holdup deposits in contaminated gaseous diffusion piping during decommissioning.
  • To reduce reliance on manual, elevated, and hazardous external measurements that require cutting away thermal insulation.
  • To improve measurement certainty and spatial localization by enabling internal pipe radiation detection.
  • To design a robot capable of autonomous operation in complex pipe geometries with obstacle detection and dual-pipe-size adaptability.
  • To provide high-resolution, in-pipe radiation data that are unattainable through external measurements alone.

Proposed method

  • The RadPiper robot employs a sodium iodide scintillation detector in a disc-collimated assembly to maximize detection efficiency from inside the pipe.
  • It uses precision distance measurement systems to accurately localize radiation readings along the pipe axis.
  • The robot integrates onboard imaging and 3D modeling to reconstruct internal pipe geometry and detect obstacles in real time.
  • It features a mechanical design that allows transformation between two standard pipe diameters, enhancing deployment versatility.
  • Autonomous navigation is achieved through embedded control systems that support self-localization and obstacle avoidance.
  • Data fusion techniques combine radiation counts, distance traveled, and visual data to generate spatially accurate holdup assessments.

Experimental results

Research questions

  • RQ1Can an in-pipe robot achieve significantly higher radiation count rates than external through-pipe measurements?
  • RQ2How accurately can the robot localize radiation measurements within complex pipe networks?
  • RQ3To what extent can the robot autonomously navigate and detect obstacles in real-world gaseous diffusion piping?
  • RQ4How does the robot’s internal measurement approach improve measurement certainty compared to external methods?
  • RQ5What is the system’s performance in terms of deployment tolerance and safeguarding during field operations?

Key findings

  • The RadPiper robot achieved a count rate increase of up to 10 times higher than external measurements due to proximity to the radiation source.
  • Localization accuracy was demonstrated to be within ±10 cm over extended pipe runs, enabling precise mapping of holdup deposits.
  • The robot successfully navigated and detected obstacles in real-world pipe configurations during field testing.
  • Deployment tolerance tests confirmed reliable operation across varying pipe diameters and surface conditions.
  • Safeguarding tests confirmed that the robot maintains data integrity and operational consistency under field conditions.
  • Integrated system tests demonstrated successful data fusion of radiation, distance, and visual data for comprehensive pipe interior characterization.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.