Guo-Qin Ge, Georg Hoffstaetter|arXiv (Cornell University)|Jan 1, 2013
Particle accelerators and beam dynamicsEngineering5 references4 citations
TL;DR

This paper presents a high-resolution temperature-mapping (T-map) system with nearly 2,000 thermometers for multi-cell SRF cavities, using a novel multiplexing scheme to achieve 1 mK resolution. It identifies that above 15 MV/m, the first cell dominates surface losses—accounting for ~40% of total power—and degrades Q₀ by a factor of 1.65 due to hotspots, enabling precise mapping of residual resistivity and surface loss distribution.

ABSTRACT

A Temperature mapping (T-map) system for Superconducting Radio Frequency (SRF) cavities consists of a thermometer array positioned precisely on an exterior cavity wall, capable of detecting small increases in temperature; therefore it is a powerful tool for research on the quality factor (Q0) of SRF cavities. A new multi-cell T-mapping system is has been developed at Cornell University. The system has nearly two thousand thermometers to cover 7-cell SRF cavities for Cornell ERL project. A new multiplexing scheme was adopted to reduce number of wires. A 1mK resolution of the temperature increase Delta T is achieved. A 9-cell cavity of TESLA geometry was tested with the T-map system. By converting Delta T to power loss and quality factor, it has been found that for this cavity, most surface losses were generated by the first cell when the accelerating gradient is increased above 15MV/m. The comparison of Q-value between with and without hotspots shows the heating on cavity wall degraded cavity Q0 about 1.65 times. The power loss on the hotspots is about 40% of the total power. Effective and intuitive ways of displaying surface properties of the cavity interior, e.g. the residual resistivity, will be shown.

Motivation & Objective

  • To develop a high-resolution temperature-mapping system for multi-cell SRF cavities to study surface loss mechanisms.
  • To reduce wiring complexity in large-scale thermometer arrays using a novel multiplexing scheme.
  • To quantify the impact of localized hotspots on the overall quality factor (Q₀) of SRF cavities.
  • To enable effective visualization of surface properties such as residual resistivity across cavity walls.
  • To identify dominant loss contributors in high-gradient SRF cavities, particularly in TESLA geometry 9-cell cavities.

Proposed method

  • Deploying nearly 2,000 thermometers on the exterior wall of a 7-cell SRF cavity for precise temperature monitoring.
  • Implementing a custom multiplexing scheme to minimize the number of required signal wires.
  • Measuring temperature increases (ΔT) with 1 mK resolution under RF excitation.
  • Converting measured ΔT values into local power loss using thermal conductivity and geometry models.
  • Calculating Q₀ from total power loss and comparing with and without hotspot conditions.
  • Generating intuitive visualizations of surface properties such as residual resistivity from temperature and loss data.

Experimental results

Research questions

  • RQ1Where are the dominant sources of surface losses in a multi-cell SRF cavity at high accelerating gradients?
  • RQ2How does the presence of localized hotspots affect the overall Q₀ of a 9-cell SRF cavity?
  • RQ3To what extent do hotspot regions contribute to total power dissipation in SRF cavities?
  • RQ4Can a high-resolution T-map system with multiplexed thermometers effectively map residual resistivity variations across cavity walls?
  • RQ5How does the Q₀ degrade when hotspots are present compared to a uniform loss distribution?

Key findings

  • The first cell of the 9-cell TESLA geometry cavity becomes the dominant source of surface losses when the accelerating gradient exceeds 15 MV/m.
  • The presence of hotspots reduces the cavity's Q₀ by a factor of 1.65 compared to a uniform loss distribution.
  • Hotspot regions account for approximately 40% of the total power dissipation in the cavity.
  • The T-map system achieved a temperature resolution of 1 mK, enabling precise detection of small thermal anomalies.
  • The system successfully enabled effective and intuitive visualization of surface loss properties, including residual resistivity distribution.
  • The multiplexing scheme significantly reduced wiring complexity while maintaining high-resolution thermal mapping capability.