[Paper Review] A tweezer clock with half-minute atomic coherence at optical frequencies and high relative stability
This paper presents a 2D optical tweezer array clock using 88Sr atoms, achieving atomic coherence times exceeding 40 seconds and a relative fractional frequency stability of 5.2(3)×10⁻¹⁷ (τ/s)⁻¹/². By combining a shallow clock-magic potential at 813 nm with a tightly confining auxiliary potential at 515 nm, the system enables high-fidelity state preparation, site-resolved readout, and suppressed decoherence, leading to quality factors exceeding 10¹⁶ and enabling long-lived quantum coherence in ensembles of ~150 atoms.
The preparation of large, low-entropy, highly coherent ensembles of identical quantum systems is foundational for many studies in quantum metrology, simulation, and information. Here, we realize these features by leveraging the favorable properties of tweezer-trapped alkaline-earth atoms while introducing a new, hybrid approach to tailoring optical potentials that balances scalability, high-fidelity state preparation, site-resolved readout, and preservation of atomic coherence. With this approach, we achieve trapping and optical clock excited-state lifetimes exceeding $ 40 $ seconds in ensembles of approximately $ 150 $ atoms. This leads to half-minute-scale atomic coherence on an optical clock transition, corresponding to quality factors well in excess of $10^{16}$. These coherence times and atom numbers reduce the effect of quantum projection noise to a level that is on par with leading atomic systems, yielding a relative fractional frequency stability of $5.2(3) imes10^{-17}~( au/s)^{-1/2}$ for synchronous clock comparisons between sub-ensembles within the tweezer array. When further combined with the microscopic control and readout available in this system, these results pave the way towards long-lived engineered entanglement on an optical clock transition in tailored atom arrays.
Motivation & Objective
- To achieve long-lived, high-coherence atomic ensembles in a scalable optical tweezer array for quantum metrology.
- To reduce quantum projection noise by increasing atom number while preserving coherence.
- To enable microscopic control and site-resolved readout in a large, coherent atomic array.
- To demonstrate high stability in a tweezer-based optical clock by independently controlling tunneling and scattering.
- To pave the way for engineered entanglement and long-coherence quantum information processing on optical clock transitions.
Proposed method
- Utilizes a hybrid optical potential: a shallow 813 nm 'science' potential for clock operation and a 515 nm 'auxiliary' potential for tight confinement.
- Employs a 320-site tweezer array with 1.2–1.5 µm spacing, enabling high-density, site-resolved trapping of 88Sr atoms.
- Applies sideband cooling via a crossed-beam optical lattice to achieve sub-0.1 phonon occupation in all directions.
- Performs adiabatic transfer from auxiliary to science potential to preserve coherence and enable long-lived clock-state populations.
- Uses Ramsey spectroscopy with synchronous comparisons across sub-ensembles to measure stability.
- Models decoherence using a master equation including spontaneous emission, blackbody radiation, and Rayleigh scattering, with numerical simulation over 10 phase shifts to account for laser noise.
Experimental results
Research questions
- RQ1Can atomic coherence times exceeding 40 seconds be achieved in a large, site-resolved tweezer array of 88Sr atoms?
- RQ2What is the maximum achievable relative fractional frequency stability in a tweezer-based optical clock with ~150 atoms?
- RQ3Can independent control of tunneling and Raman scattering be leveraged to extend coherence beyond limits in fixed-lattice systems?
- RQ4To what extent does finite-temperature motional excitation limit clock pulse fidelity in tightly confined traps?
- RQ5Can the combination of high-fidelity state preparation, long coherence, and site-resolved control enable future entanglement-based quantum metrology?
Key findings
- The system achieves an excited-state lifetime of 46(5) seconds in the 3P0 → 3P1 clock transition, with coherence times up to 48(8) seconds for select atoms.
- A half-minute-scale atomic coherence is observed, corresponding to a quality factor Q = 6.5(1.1)×10¹⁶.
- The relative fractional frequency stability reaches 5.2(3)×10⁻¹⁷ (τ/s)⁻¹/² for synchronous comparisons between sub-ensembles.
- The average phonon occupation after sideband cooling is 0.07±0.06 in axial and radial directions, indicating sub-0.1 phonon state preparation.
- Modeling shows that π-pulse fidelity is limited to 0.90 at current conditions, but could reach 99.94% with improved confinement.
- The system demonstrates a 100-nm precision in atomic positioning and site-resolved readout, enabling future control of many-body entanglement.