[Paper Review] Accuracy Improvement for Fully Convolutional Networks via Selective Augmentation with Applications to Electrocardiogram Data
This paper proposes a selective data augmentation method for Fully Convolutional Networks (FCNs) that targets only low-confidence predictions from a validation set for augmentation, improving ECG-based myocardial infarction classification. By retraining the model with resampled segments from these low-confidence samples, the approach achieves 90% accuracy—significantly outperforming the baseline FCN's 82%—with optimal performance at a confidence threshold of α = 0.5.
Deep learning methods have shown suitability for time series classification in the health and medical domain, with promising results for electrocardiogram data classification. Successful identification of myocardial infarction holds life saving potential and any meaningful improvement upon deep learning models in this area is of great interest. Conventionally, data augmentation methods are applied universally to the training set when data are limited in order to ameliorate data resolution or sample size. In the method proposed in this study, data augmentation was not applied in the context of data scarcity. Instead, samples that yield low confidence predictions were selectively augmented in order to bolster the model's sensitivity to features or patterns less strongly associated with a given class. This approach was tested for improving the performance of a Fully Convolutional Network. The proposed approach achieved 90 percent accuracy for classifying myocardial infarction as opposed to 82 percent accuracy for the baseline, a marked improvement. Further, the accuracy of the proposed approach was optimal near a defined upper threshold for qualifying low confidence samples and decreased as this threshold was raised to include higher confidence samples. This suggests exclusively selecting lower confidence samples for data augmentation comes with distinct benefits for electrocardiogram data classification with Fully Convolutional Networks.
Motivation & Objective
- To improve the classification accuracy of Fully Convolutional Networks (FCNs) for electrocardiogram (ECG) data, particularly in detecting myocardial infarction.
- To address the limitation of conventional data augmentation, which uniformly applies transformations regardless of prediction confidence.
- To investigate whether selectively augmenting only low-confidence samples—those with weaker feature associations—can enhance model sensitivity to subtle or rare patterns.
- To identify an optimal threshold for selecting low-confidence samples that maximizes performance improvement.
Proposed method
- The method identifies low-confidence predictions from a validation set using a confidence threshold α, defined as the absolute difference between predicted class probabilities.
- Segments of time series data corresponding to low-confidence predictions are resampled and reintroduced into the training set.
- The model is retrained on the augmented training set and re-evaluated on a separate test set to measure performance.
- The approach uses a fixed window size of 70% of the original time series length for segmentation of resampled segments.
- The confidence threshold α is varied from 0.1 to 0.8 to evaluate its impact on model accuracy and loss.
- A baseline FCN model is trained without any selective augmentation for comparison.
Experimental results
Research questions
- RQ1Does selectively augmenting only low-confidence predictions improve FCN performance in ECG time series classification compared to conventional universal augmentation?
- RQ2What is the optimal confidence threshold α for selecting low-confidence samples for augmentation in this context?
- RQ3How does increasing the confidence threshold α affect model accuracy and loss, and does performance degrade when higher-confidence samples are included?
- RQ4Can this method improve model sensitivity to subtle or weakly correlated features in ECG data without overfitting?
- RQ5Is the performance improvement robust across multiple model iterations and hyperparameter settings?
Key findings
- The proposed method achieved 90% accuracy on the test set, a significant improvement over the baseline FCN's 82% accuracy.
- The highest-performing model used a confidence threshold α = 0.5, achieving 90% accuracy and a loss of 0.3172.
- Performance declined when the confidence threshold was increased beyond α = 0.5, with the worst-performing model (α = 0.7) achieving only 78% accuracy.
- All models trained with the new method except one (α = 0.7) outperformed the baseline in both accuracy and loss.
- The results support the hypothesis that selectively augmenting low-confidence samples enhances model sensitivity to less prominent features.
- The optimal threshold for selection was found to be near α = 0.5, indicating that including higher-confidence samples diminishes the benefit of selective augmentation.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.