[Paper Review] Adaptive Intelligent Secondary Control of Microgrids Using a Biologically-Inspired Reinforcement Learning
This paper proposes a model-free, biologically-inspired adaptive intelligent secondary controller for microgrids using Brain Emotional Learning-Based Intelligent Control (BELBIC) to stabilize voltage and frequency under system uncertainties and disturbances. The controller learns online without requiring detailed system dynamics, demonstrating faster response, lower overshoot, and reduced error compared to PID and neural network-based controllers in simulations.
In this paper, a biologically-inspired adaptive intelligent secondary controller is developed for microgrids to tackle system dynamics uncertainties, faults, and/or disturbances. The developed adaptive biologically-inspired controller adopts a novel computational model of emotional learning in mammalian limbic system. The learning capability of the proposed biologically-inspired intelligent controller makes it a promising approach to deal with the power system non-linear and volatile dynamics without increasing the controller complexity, and maintain the voltage and frequency stabilities by using an efficient reference tracking mechanism. The performance of the proposed intelligent secondary controller is validated in terms of the voltage and frequency absolute errors in the simulated microgrid. Simulation results highlight the efficiency and robustness of the proposed intelligent controller under the fault conditions and different system uncertainties compared to other benchmark controllers.
Motivation & Objective
- Address the challenge of stabilizing microgrids under unknown or time-varying system dynamics and disturbances.
- Develop a model-free secondary controller that adapts in real time without relying on detailed system knowledge.
- Improve robustness and performance of microgrid control under faults, parameter variations, and operational transitions.
- Enable efficient, real-time reference tracking for voltage and frequency restoration in islanded microgrids.
- Demonstrate superiority over conventional PID and neural network-based controllers in dynamic and uncertain environments.
Proposed method
- Utilizes Brain Emotional Learning-Based Intelligent Control (BELBIC), inspired by the mammalian limbic system, to model emotional learning in control systems.
- Employs Sensory Inputs (SI) and Emotional Signals (ES) as dual inputs to the BELBIC model for adaptive control action generation.
- Designs an intelligent reference tracking mechanism that dynamically adjusts control signals based on error feedback and system response.
- Implements the controller in a hierarchical microgrid control framework, operating at the secondary control level to correct deviations from nominal voltage and frequency.
- Uses simulation-based training and validation with real-time parameter adaptation, avoiding offline learning from predefined datasets.
- Applies no additional tuning when system parameters such as turbine gain or AVR constants vary, testing inherent robustness.
Experimental results
Research questions
- RQ1Can a biologically-inspired, model-free controller effectively stabilize voltage and frequency in microgrids with unknown or uncertain dynamics?
- RQ2How does the BELBIC-based controller compare to conventional PID and neural network-based controllers in terms of response speed and error reduction?
- RQ3To what extent can the proposed controller maintain performance under sudden disturbances, such as islanding events?
- RQ4How robust is the controller to variations in key system parameters like turbine gain and AVR time constants?
- RQ5Can the controller adapt in real time without requiring system identification or re-tuning?
Key findings
- The BELBIC-based controller achieved faster response and lower overshoot than both PID and neural network-based controllers during islanding transitions at 0.2 seconds.
- Voltage and frequency absolute errors were consistently lower with the BELBIC controller, demonstrating superior tracking accuracy.
- The mean square error (MSE) for both voltage and frequency remained significantly lower across all tested parameter variations, especially for turbine gain (KG).
- The BELBIC controller showed minimal performance degradation when system parameters such as KG, Ta, and TG were varied, indicating high robustness.
- The controller maintained stable performance without re-tuning, even when system dynamics changed due to wear or environmental factors.
- Sensitivity analysis confirmed that the BELBIC controller exhibited smaller MSE variation across parameter changes compared to PID and neural network-based alternatives.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.