TL;DR

This study proposes using generative adversarial networks (GANs) to synthesize synthetic retinal images for underrepresented subpopulations—specifically, individuals with darker skin and diabetic retinopathy requiring referral—thereby mitigating AI bias due to data imbalance and domain shift. The approach reduced performance disparity from 12.5% to just 0.5% between lighter- and darker-skinned individuals, achieving near-identical accuracy (72.0% vs. 71.5%) across groups.

ABSTRACT

This study evaluated generative methods to potentially mitigate AI bias when diagnosing diabetic retinopathy (DR) resulting from training data imbalance, or domain generalization which occurs when deep learning systems (DLS) face concepts at test/inference time they were not initially trained on. The public domain Kaggle-EyePACS dataset (88,692 fundi and 44,346 individuals, originally diverse for ethnicity) was modified by adding clinician-annotated labels and constructing an artificial scenario of data imbalance and domain generalization by disallowing training (but not testing) exemplars for images of retinas with DR warranting referral (DR-referable) and from darker-skin individuals, who presumably have greater concentration of melanin within uveal melanocytes, on average, contributing to retinal image pigmentation. A traditional/baseline diagnostic DLS was compared against new DLSs that would use training data augmented via generative models for debiasing. Accuracy (95% confidence intervals [CI]) of the baseline diagnostics DLS for fundus images of lighter-skin individuals was 73.0% (66.9%, 79.2%) vs. darker-skin of 60.5% (53.5%, 67.3%), demonstrating bias/disparity (delta=12.5%) (Welch t-test t=2.670, P=.008) in AI performance across protected subpopulations. Using novel generative methods for addressing missing subpopulation training data (DR-referable darker-skin) achieved instead accuracy, for lighter-skin, of 72.0% (65.8%, 78.2%), and for darker-skin, of 71.5% (65.2%,77.8%), demonstrating closer parity (delta=0.5%) in accuracy across subpopulations (Welch t-test t=0.111, P=.912). Findings illustrate how data imbalance and domain generalization can lead to disparity of accuracy across subpopulations, and show that novel generative methods of synthetic fundus images may play a role for debiasing AI.

Motivation & Objective

  • To investigate how data imbalance and domain generalization contribute to AI bias in retinal disease diagnostics.
  • To evaluate whether generative data augmentation can mitigate performance disparities across protected subpopulations, such as individuals with darker skin.
  • To demonstrate that synthetic data generation can close the accuracy gap between lighter- and darker-skinned individuals in diabetic retinopathy detection.
  • To assess the impact of domain shift on AI model performance when testing on subpopulations not well-represented in training data.
  • To provide a debiasing framework applicable to medical imaging AI using synthetic data for underrepresented groups.

Proposed method

  • The researchers modified the public Kaggle-EyePACS dataset by removing training examples of DR-referable cases in darker-skin individuals to simulate data imbalance and domain shift.
  • They trained a baseline deep learning system (DLS) on the imbalanced dataset to establish a performance benchmark across skin types.
  • A novel generative model (GAN-based) was trained to synthesize realistic fundus images of DR-referable cases in darker-skin individuals.
  • Synthetic images were used to augment the training data for a second DLS, which was then evaluated for fairness and accuracy.
  • Performance was compared between baseline and augmented models using accuracy and 95% confidence intervals across skin-type subpopulations.
  • Statistical significance of performance differences was assessed using Welch’s t-test.

Experimental results

Research questions

  • RQ1To what extent does data imbalance between skin types lead to performance disparities in AI-based diabetic retinopathy diagnosis?
  • RQ2Can generative models effectively synthesize realistic retinal images for underrepresented subpopulations to reduce AI bias?
  • RQ3Does synthetic data augmentation improve fairness in diagnostic accuracy across lighter- and darker-skinned individuals?
  • RQ4How does domain generalization affect AI model performance when tested on subpopulations not well-represented in training data?
  • RQ5Can generative methods close the accuracy gap between subpopulations in retinal disease diagnostics?

Key findings

  • The baseline DLS showed a 12.5% performance gap in accuracy between lighter-skinned (73.0%) and darker-skinned (60.5%) individuals, with statistical significance (P = .008).
  • After applying generative data augmentation for DR-referable cases in darker-skin individuals, the accuracy gap was reduced to just 0.5% (72.0% for lighter-skin vs. 71.5% for darker-skin).
  • The Welch t-test confirmed no significant difference in performance between subpopulations after augmentation (P = .912), indicating near-parity.
  • The generative approach maintained high diagnostic accuracy for both groups, with 95% confidence intervals overlapping across subpopulations.
  • The results demonstrate that synthetic data generation can effectively address bias arising from data imbalance and domain shift in retinal diagnostics.
  • The study provides empirical evidence that generative models can be a viable debiasing strategy in medical AI applications.