Skip to main content
QUICK REVIEW

[Paper Review] Addressing cognitive bias in medical language models

Samuel Schmidgall, Carl Harris|arXiv (Cornell University)|Feb 12, 2024
Machine Learning in HealthcareComputer Science10 citations
TL;DR

BiasMedQA is a benchmark assessing cognitive bias susceptibility in medical LLMs using USMLE-style questions; GPT-4 shows strongest resilience to bias, while other models are substantially affected. The study also proposes mitigation strategies (bias education, one-shot, few-shot) with mixed improvements.

ABSTRACT

There is increasing interest in the application large language models (LLMs) to the medical field, in part because of their impressive performance on medical exam questions. While promising, exam questions do not reflect the complexity of real patient-doctor interactions. In reality, physicians' decisions are shaped by many complex factors, such as patient compliance, personal experience, ethical beliefs, and cognitive bias. Taking a step toward understanding this, our hypothesis posits that when LLMs are confronted with clinical questions containing cognitive biases, they will yield significantly less accurate responses compared to the same questions presented without such biases. In this study, we developed BiasMedQA, a benchmark for evaluating cognitive biases in LLMs applied to medical tasks. Using BiasMedQA we evaluated six LLMs, namely GPT-4, Mixtral-8x70B, GPT-3.5, PaLM-2, Llama 2 70B-chat, and the medically specialized PMC Llama 13B. We tested these models on 1,273 questions from the US Medical Licensing Exam (USMLE) Steps 1, 2, and 3, modified to replicate common clinically-relevant cognitive biases. Our analysis revealed varying effects for biases on these LLMs, with GPT-4 standing out for its resilience to bias, in contrast to Llama 2 70B-chat and PMC Llama 13B, which were disproportionately affected by cognitive bias. Our findings highlight the critical need for bias mitigation in the development of medical LLMs, pointing towards safer and more reliable applications in healthcare.

Motivation & Objective

  • Assess how common cognitive biases affect medical language models on clinically relevant tasks.
  • Develop BiasMedQA as a benchmark to evaluate bias in LLM medical decision-making.
  • Compare multiple models across biases to identify resilience and failure modes.
  • Propose and evaluate bias mitigation strategies to improve robustness in clinical prompts.

Proposed method

  • Create BiasMedQA by injecting seven cognitive biases (self-diagnosis, recency, confirmation, frequency, cultural, status quo, false consensus) into USMLE-style MedQA questions.
  • Evaluate six LLMs (GPT-4, Mixtral-8x70B, GPT-3.5, PaLM-2, Llama 2 70B-chat, PMC Llama 13B) on 1,273 MedQA questions.
  • Measure diagnostic accuracy with and without biased prompts.
  • Analyze relative declines in accuracy across models and biases.
  • Test three bias mitigation strategies (bias education, one-shot, few-shot) and report their effects.
Figure 1: Demonstration of language model interaction scenario given questions from the US Medical Licensing Exam. (Left) Graphical depiction of language model interaction. (Middle) Textual depiction of unbiased prompt for LLM. (Right) Prompt with example of cognitive bias prompt.
Figure 1: Demonstration of language model interaction scenario given questions from the US Medical Licensing Exam. (Left) Graphical depiction of language model interaction. (Middle) Textual depiction of unbiased prompt for LLM. (Right) Prompt with example of cognitive bias prompt.

Experimental results

Research questions

  • RQ1How do clinically relevant cognitive biases impact the diagnostic accuracy of different medical LLMs?
  • RQ2Which models demonstrate robustness or vulnerability to bias prompts, and under which biases?
  • RQ3Can mitigation strategies reduce bias-induced accuracy losses, and are gains consistent across models?

Key findings

  • Bias prompts reduce model accuracy across all evaluated models.
  • GPT-4 shows the strongest resilience to bias prompts, outperforming peers on unbiased prompts and suffering smaller declines under bias.
  • Llama 2 70B-chat and PMC Llama 13B are disproportionately affected by cognitive bias compared to GPT-4.
  • False consensus bias generally causes the largest average accuracy drop (~24.9 percentage points across models).
  • Frequency and recency biases cause substantial declines (roughly 18.2% and 12.9% respectively on average), while confirmation bias is less impactful (8.1% average).
  • Three mitigation strategies (bias education, one-shot, few-shot) yield improvements, with GPT-4 often showing the largest gains; PaLM-2 and some open models face safety-filter-related limitations that reduce reporting.
Figure 2: Model comparison following cognitive bias addition. Accuracy is indicated by the distance between each dot and the origin (e.g., a radius of 0.8 corresponds to 80% accuracy). The names of each cognitive bias surround the circle. Table 1 shows the results in tabular format.
Figure 2: Model comparison following cognitive bias addition. Accuracy is indicated by the distance between each dot and the origin (e.g., a radius of 0.8 corresponds to 80% accuracy). The names of each cognitive bias surround the circle. Table 1 shows the results in tabular format.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.